Minimization of Torque Ripple in the DFIG-DC System Via Predictive Delay Compensation

Torque ripple caused by stator current and flux harmonics is one of the main issues in the doubly fed induction generator (DFIG)-dc system, which inherently has to operate with distorted waveforms produced by the diode commutation. This paper proposes a torque-ripple mitigation strategy based on a predictive estimation of the reciprocal of flux linkage. The predictive estimation compensates for the intrinsic delay in the actuation of the torque-ripple rejection signal through the rotor current control loops. Unlike other approaches relying on complex current regulators with selective harmonic tracking, this strategy is based on well-established proportional-integral (PI) controllers for the rotor currents. PI current controllers can then still have bandwidth values typical of usual DFIG systems. Simulations and experiments on a test-rig show that the compensation strategy achieves a strong torque ripple reduction and is very robust against stator frequency variations.

[1]  Himanshu Misra,et al.  Analysis of Stand-Alone DFIG-DC System and DC Voltage Regulation With Reduced Sensors , 2017, IEEE Transactions on Industrial Electronics.

[2]  G. D. Marques,et al.  Stator Frequency Regulation in a Field-Oriented Controlled DFIG Connected to a DC Link , 2014, IEEE Transactions on Industrial Electronics.

[3]  William A. Adkins,et al.  Ordinary Differential Equations , 2018, Theoretical and Mathematical Physics.

[4]  D. F. Howard,et al.  Feedforward Transient Compensation Control for DFIG Wind Turbines During Both Balanced and Unbalanced Grid Disturbances , 2013, IEEE Transactions on Industry Applications.

[5]  Heng Nian,et al.  Dynamic Modeling and Improved Control of DFIG Under Distorted Grid Voltage Conditions , 2011, IEEE Transactions on Energy Conversion.

[6]  G. D. Marques,et al.  Stator Flux Active Damping Methods for Field-Oriented Doubly Fed Induction Generator , 2012, IEEE Transactions on Energy Conversion.

[7]  Dong Chen,et al.  Control and Operation of a DC Microgrid With Variable Generation and Energy Storage , 2011, IEEE Transactions on Power Delivery.

[8]  F. Liu,et al.  DC Bus Voltage Control for a Distributed Power System , 2003 .

[9]  Gil D. Marques,et al.  Operation and design issues of a doubly fed induction generator stator connected to a dc net by a diode rectifier , 2014 .

[10]  Dehong Xu,et al.  Stator Current Harmonic Control With Resonant Controller for Doubly Fed Induction Generator , 2012, IEEE Transactions on Power Electronics.

[11]  Gil D. Marques,et al.  Torque Ripple Reduction in a DFIG-DC System by Resonant Current Controllers , 2015, IEEE Transactions on Power Electronics.

[12]  Heng Nian,et al.  A novel DC grid connected DFIG system with active power filter based on predictive current control , 2011, 2011 International Conference on Electrical Machines and Systems.

[13]  Jon Clare,et al.  Doubly fed induction generator using back-to-back PWM converters and its application to variable-speed wind-energy generation , 1996 .

[14]  Guillermo O. García,et al.  Adaptive Observer for Sensorless Control of Stand-Alone Doubly Fed Induction Generator , 2009, IEEE Transactions on Industrial Electronics.

[15]  Kai Shi,et al.  Wide-Speed-Range-Operation Dual Stator-Winding Induction Generator DC Generating System for Wind Power Applications , 2015, IEEE Transactions on Power Electronics.

[16]  G. D. Marques,et al.  Field-Weakening Control for Efficiency Optimization in a DFIG Connected to a DC-Link , 2016, IEEE Transactions on Industrial Electronics.

[17]  Lingling Fan,et al.  Harmonic Analysis of a DFIG for a Wind Energy Conversion System , 2010, IEEE Transactions on Energy Conversion.

[18]  Chandan Chakraborty,et al.  Dual Stator Winding Induction Machine: Problems, Progress, and Future Scope , 2015, IEEE Transactions on Industrial Electronics.

[19]  Roberto Cárdenas,et al.  Overview of control systems for the operation of DFIGs in wind energy applications , 2013, IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society.

[20]  Hiroaki Kakigano,et al.  Low-Voltage Bipolar-Type DC Microgrid for Super High Quality Distribution , 2010, IEEE Transactions on Power Electronics.

[21]  Juan C. Vasquez,et al.  DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues , 2016, IEEE Transactions on Power Electronics.

[22]  T. Thiringer,et al.  Evaluation of current control methods for wind turbines using doubly-fed induction machines , 2005, IEEE Transactions on Power Electronics.

[23]  Himanshu J. Bahirat,et al.  An All-DC Offshore Wind Farm With Series-Connected Turbines: An Alternative to the Classical Parallel AC Model? , 2013, IEEE Transactions on Industrial Electronics.

[24]  Matteo F. Iacchetti,et al.  Inner Control Method and Frequency Regulation of a DFIG Connected to a DC Link , 2014, IEEE Transactions on Energy Conversion.

[25]  Ramesh Kumar Tripathi,et al.  DC grid/bus tied DFIG based wind energy system , 2017 .

[26]  Chao Wu,et al.  Direct Resonant Control Strategy for Torque Ripple Mitigation of DFIG Connected to DC Link through Diode Rectifier on Stator , 2017, IEEE Transactions on Power Electronics.

[27]  Heng Nian,et al.  Coordinated control strategy for doubly-fed induction generator with DC connection topology , 2015 .

[28]  Amit K. Jain,et al.  Wound Rotor Induction Generator With Sensorless Control and Integrated Active Filter for Feeding Nonlinear Loads in a Stand-Alone Grid , 2008, IEEE Transactions on Industrial Electronics.

[29]  Heng Nian,et al.  Voltage Imbalance Compensation for Doubly Fed Induction Generator Using Direct Resonant Feedback Regulator , 2016, IEEE Transactions on Energy Conversion.

[30]  Lingling Fan,et al.  Harmonic Analysis of aD FIG for aW ind Energy Conversion System , 2010 .