Limited angle C-arm tomosynthesis reconstruction algorithms

In this paper, C-arm tomosynthesis with digital detector was investigated as a novel three dimensional (3D) imaging technique. Digital tomosythses is an imaging technique to provide 3D information of the object by reconstructing slices passing through the object, based on a series of angular projection views with respect to the object. C-arm tomosynthesis provides two dimensional (2D) X-ray projection images with rotation (∓20 angular range) of both X-ray source and detector. In this paper, four representative reconstruction algorithms including point by point back projection (BP), filtered back projection (FBP), simultaneous algebraic reconstruction technique (SART) and maximum likelihood expectation maximization (MLEM) were investigated. Dataset of 25 projection views of 3D spherical object that located at center of C-arm imaging space was simulated from 25 angular locations over a total view angle of 40 degrees. With reconstructed images, 3D mesh plot and 2D line profile of normalized pixel intensities on focus reconstruction plane crossing the center of the object were studied with each reconstruction algorithm. Results demonstrated the capability to generate 3D information from limited angle C-arm tomosynthesis. Since C-arm tomosynthesis is relatively compact, portable and can avoid moving patients, it has been investigated for different clinical applications ranging from tumor surgery to interventional radiology. It is very important to evaluate C-arm tomosynthesis for valuable applications.

[1]  J. Rakowski,et al.  A comparison of reconstruction algorithms for C-arm mammography tomosynthesis. , 2006, Medical physics.

[2]  Qizhi Zhang,et al.  Digital tomosynthesis of joints based on a C-arm system , 2005 .

[3]  James V. Byrne,et al.  C-arm flat detector computed tomography: the technique and its applications in interventional neuro-radiology , 2010, Neuroradiology.

[4]  M. Daly,et al.  Intraoperative Cone-Beam Computed Tomography and Multi-Slice Computed Tomography in Temporal Bone Imaging for Surgical Treatment , 2014, Otolaryngology Head & Neck Surgery.

[5]  Jeffrey A. Fessler,et al.  Ieee Transactions on Image Processing: to Appear Globally Convergent Algorithms for Maximum a Posteriori Transmission Tomography , 2022 .

[6]  Nassir Navab,et al.  Enhanced 3D-reconstruction algorithms for C-Arm based interventional procedures , 2000, IEEE Trans. Medical Imaging.

[7]  Lubomir M. Hadjiiski,et al.  A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis. , 2006, Medical physics.

[8]  A. Kak,et al.  Simultaneous Algebraic Reconstruction Technique (SART): A Superior Implementation of the Art Algorithm , 1984, Ultrasonic imaging.

[9]  Otto Zhou,et al.  Breast tomosynthesis reconstruction with a multi-beam x-ray source , 2009, Medical Imaging.

[10]  Ying Chen Digital breast tomosynthesis (DBT) --- A novel imaging technology to improve early breast cancer detection: Implementation, comparison and optimization , 2007 .

[11]  Weihua Zhou,et al.  Image reconstruction and imaging configuration optimization with a novel nanotechnology enabled breast tomosynthesis multi-beam X-ray system , 2012 .

[12]  Ying Chen,et al.  Parameter optimization of relaxed Ordered Subsets Pre-computed Back Projection (BP) based Penalized-Likelihood (OS-PPL) reconstruction in limited-angle X-ray tomography , 2013, Comput. Medical Imaging Graph..

[13]  Yoshito Otake,et al.  Intraoperative C‐arm cone‐beam computed tomography: Quantitative analysis of surgical performance in skull base surgery , 2012, The Laryngoscope.

[14]  M. Kuo,et al.  C-arm cone-beam CT: general principles and technical considerations for use in interventional radiology. , 2009, Journal of vascular and interventional radiology : JVIR.

[15]  J H Siewerdsen,et al.  Image quality and localization accuracy in C-arm tomosynthesis-guided head and neck surgery. , 2007, Medical physics.

[16]  Cyril Riddell,et al.  Circular tomosynthesis implemented with a clinical interventional flat-panel based C-Arm: initial performance study , 2007, SPIE Medical Imaging.

[17]  Georg Rose,et al.  Performance evaluation of a C-Arm CT perfusion phantom , 2013, International Journal of Computer Assisted Radiology and Surgery.

[18]  M. Takahashi,et al.  Multislice CT , 2001, Medical Radiology.

[19]  Calibration of a C-arm X-Ray System for Its Use in Tomography , 2014 .

[20]  Ying Chen,et al.  Importance of point-by-point back projection correction for isocentric motion in digital breast tomosynthesis: relevance to morphology of structures such as microcalcifications. , 2007, Medical physics.

[21]  Ying Chen,et al.  An application of pre-computed backprojection based penalized-likelihood (PPL) image reconstruction on stationary digital breast tomosynthesis , 2013, Medical Imaging.

[22]  Luca Brunese,et al.  C-arm cone-beam computed tomography in interventional oncology: technical aspects and clinical applications , 2014, La radiologia medica.

[23]  N. Navab,et al.  Enhanced 3-D-reconstruction algorithm for C-arm systems suitable for interventional procedures , 2000, IEEE Transactions on Medical Imaging.