Seismic Performance of Reinforced Concrete Frames Retrofitted with Self-Centering Hybrid Wall

This paper presents the results of a parametric study on the seismic behavior of self-centering hybrid walls as a new seismic retrofit method for reinforced concrete (RC) frames. A special base connection that isolates the wall from its foundation ensures the controlled rocking behavior of the self-centering hybrid wall. This seismic retrofit scheme is very appealing because of its relatively low cost, substantially large stiffness and reasonably low base shear demand. A parametric study has been carried out to investigate the effects of several factors including strength and initial stiffness of hysteretic dampers, and others pertaining to PT tendons on the seismic behavior of the self-centering hybrid wall as the primary lateral force resisting system in a retrofitted RC frame structure. The results from a nonlinear time history analysis of a three-bay, three-story RC frame structure subjected to selected earthquake ground motions, reveal that the self-centering shear wall is fairly effective in controlling the seismic response of the retrofitted RC frame while having negligible residual story drift.

[1]  Richard Sause,et al.  Experimental and Analytical Lateral Load Response of Unbonded Post-Tensioned Precast Concrete Walls , 2004 .

[2]  Y. Kurama,et al.  Lateral Load Behavior and Seismic Design of Unbonded Post-Tensioned Precast Concrete Walls , 1999 .

[3]  Richard Sause,et al.  Ductility demands on self-centering systems under earthquake loading , 2005 .

[4]  Michael Pollino,et al.  Dynamic seismic response of controlled rocking bridge steel-truss piers , 2008 .

[5]  Jonathan P. Stewart,et al.  LOS ANGELES INVENTORY OF NONDUCTILE CONCRETE BUILDINGS FOR ANALYSIS OF SEISMIC COLLAPSE RISK HAZARDS , 2008 .

[6]  Ahmed Ghobarah,et al.  Rehabilitation of a reinforced concrete frame using eccentric steel bracing , 2001 .

[7]  Alper Ilki Seismic risk assessment and retrofitting : with special emphasis on existing low-rise structures , 2009 .

[8]  Yunfeng Zhang,et al.  Self-centering seismic retrofit scheme for reinforced concrete frame structures: SDOF system study , 2010 .

[9]  Alessandro Palermo,et al.  Improving the Seismic Performance of Existing Reinforced Concrete Buildings using Advanced Rocking Wall Solutions , 2007 .

[10]  Akira Wada,et al.  Seismic Retrofit Using Rocking Walls and Steel Dampers , 2009 .

[11]  James M. Ricles,et al.  Inelastic Link Element for EBF Seismic Analysis , 1994 .

[12]  Hyung Il Jeong Evaluation of self-centering reinforced concerete columns by shaking table tests and numerical simulations , 2007 .

[13]  James O Jirsa,et al.  Seismic Response of RC Frames Retrofitted with Steel Braces or Walls , 1995 .

[14]  John B. Mander,et al.  Seismic Performance of Precast Reinforced and Prestressed Concrete Walls , 2003 .

[15]  Stefano Pampanin Controversial aspects in seismic assessment and retrofit of structures in modern times: understanding and implementing lessons from ancient heritage , 2006 .

[16]  Chung-Che Chou,et al.  Column restraint in post‐tensioned self‐centering moment frames , 2009 .

[17]  Arturo E. Schultz,et al.  Self-Centering Behavior of Unbonded, Post-Tensioned Precast Concrete Shear Walls , 2009 .

[18]  Alessandro Palermo,et al.  EFFICIENCY OF SIMPLIFIED ALTERNATIVE MODELLING APPROACHES TO PREDICT THE SEISMIC RESPONSE OF PRECAST CONCRETE HYBRID SYSTEMS , 2005 .

[19]  Khalid M. Mosalam,et al.  Analysis of reinforced concrete columns retrofitted with fiber reinforced polymer lamina , 2007 .

[20]  Selim Günay,et al.  INFILL WALLS AS A SPINE TO ENHANCE THE SEISMIC PERFORMANCE OF NON-DUCTILE REINFORCED CONCRETE FRAMES , 2009 .

[21]  José I. Restrepo,et al.  Seismic performance of self-centering structural walls incorporating energy dissipators , 2007 .

[22]  Andre Filiatrault,et al.  Seismic response of self‐centring hysteretic SDOF systems , 2002 .

[23]  John B. Mander,et al.  Hybrid experimental analysis of semi-active rocking wall systems , 2006 .

[24]  Gokhan Pekcan,et al.  Rocking Wall–Frame Structures with Supplemental Tendon Systems , 2004 .

[25]  José I. Restrepo,et al.  Shake-Table Tests of Confined-Masonry Rocking Walls with Supplementary Hysteretic Damping , 2009 .

[26]  Jack P. Moehle,et al.  State of Research on Seismic Retrofit of Concrete Building Structures in the US , 2001 .

[27]  Songye Zhu,et al.  Seismic Analysis of Concentrically Braced Frame Systems with Self-Centering Friction Damping Braces , 2008 .

[28]  Y. Kurama Seismic Design of Unbonded Post-Tensioned Precast Concrete Walls with Supplemental Viscous Damping , 2000 .

[29]  Stephen Pessiki,et al.  Seismic behavior and design of unbonded post-tensioned precast concrete frames , 1999 .

[30]  Chin-Tung Cheng,et al.  Shaking table tests of a self-centering designed bridge substructure , 2008 .

[31]  Amr S. Elnashai,et al.  Seismic retrofit schemes for RC structures and local‐global consequences , 2006 .

[32]  Kazuo Inoue,et al.  Optimum strength ratio of hysteretic damper , 1998 .

[33]  Stefano Pampanin,et al.  Alternative Performance-Based Retrofit Strategies and Solutions for Existing RC Buildings , 2009 .

[34]  Alessandro Palermo,et al.  Dynamic Testing of Precast, Post-Tensioned Rocking Wall Systems with Alternative Dissipating Solutions , 2008 .

[35]  G. Housner The behavior of inverted pendulum structures during earthquakes , 1963 .

[36]  STEFANO PAMPANIN,et al.  PERFORMANCE-BASED SEISMIC RESPONSE OF FRAME STRUCTURES INCLUDING RESIDUAL DEFORMATIONS. PART II: MULTI-DEGREE OF FREEDOM SYSTEMS , 2003 .