Performance of interventions with manipulator-driven real-time MR guidance: implementation and initial in vitro tests.

The purpose of this work was to implement and assess the performance of interventions inside a cylindrical magnetic resonance imaging (MRI) scanner with an MR-compatible manipulator system and manipulator-driven real-time MR guidance. The interventional system is based on a seven degree-of-freedom MR-compatible manipulator, which offers man-in-the-loop control either with a graphical user interface or with a master/slave device. The position and the orientation of the interventional tool are sent to an MR scanner for a manipulator-driven dynamic update of the imaging plane to track, visualize and guide the motion of an end-effector. Studies on phantoms were performed with a cylindrical 1.5-T scanner using an operator-managed triggered gradient-recalled echo (GRE) or a computer-managed dynamic True Fast Imaging with Steady Precession (TrueFISP). Targets were acquired with an accuracy of 3.2 mm and with an in-plane path orientation of 2.5 degrees relative to the prescribed one. Path planning, including negotiation of obstacles and needle bending, was successfully performed. The signal-to-noise ratio (SNR) of TrueFISP was 25.3+/-2.1 when the manipulator was idle and was 18.6+/-2.4 during its operation. The SNR of triggered GRE (acquired only when the manipulator was idle) was 61.3+/-1.8. In conclusion, this study shows the feasibility of performing manually directed interventions inside cylindrical MR scanners with real-time MRI.

[1]  W. Chitwood,et al.  Minimally Invasive Videloscopic Mitral Valve Surgery: The Current Role of Surgical Robotics , 2000, Journal of cardiac surgery.

[2]  W. Kaiser,et al.  ROBITOM- ROBOT FOR BIOPSY AND THERAPY OF THE MAMMA , 2002 .

[3]  F. Jolesz,et al.  Genesis of interventional MRI , 1998, Journal of Magnetic Resonance Imaging.

[4]  M. Bock,et al.  An MRI-Compatible Surgical Robot for Precise Radiological Interventions , 2003, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[5]  J. Lewin,et al.  MR-guided endovascular interventions: device visualization, tracking, navigation, clinical applications, and safety aspects. , 2005, Magnetic resonance imaging clinics of North America.

[6]  John F. Canny,et al.  A Computational Approach to Edge Detection , 1986, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[7]  J. A. Derbyshire,et al.  System for MR image-guided prostate interventions: canine study. , 2003, Radiology.

[8]  F. Jolesz Invited. Interventional and intraoperative MRI: A general overview of the field , 1998, Journal of magnetic resonance imaging : JMRI.

[9]  M Wendt,et al.  Active MR guidance of interventional devices with target‐navigation , 2000, Magnetic resonance in medicine.

[10]  Nikolaos V Tsekos,et al.  A prototype manipulator for magnetic resonance-guided interventions inside standard cylindrical magnetic resonance imaging scanners. , 2005, Journal of biomechanical engineering.

[11]  C. N. Coleman,et al.  System for prostate brachytherapy and biopsy in a standard 1.5 T MRI scanner , 2004, Magnetic resonance in medicine.

[12]  M Wendt,et al.  A multielement RF coil for MRI guidance of interventional devices , 2001, Journal of magnetic resonance imaging : JMRI.

[13]  G. Weinstein,et al.  Maintenance of Hemostasis in Transoral Robotic Surgery , 2005, ORL.

[14]  Arne Reykowski,et al.  Active device tracking and high‐resolution intravascular MRI using a novel catheter‐based, opposed‐solenoid phased array coil , 2004, Magnetic resonance in medicine.

[15]  Hiroshi Iseki,et al.  Endoscope Manipulator for Trans-nasal Neurosurgery, Optimized for and Compatible to Vertical Field Open MRI , 2002, MICCAI.

[16]  F. Jolesz,et al.  Invited. Compatible instrumentation for intraoperative MRI: Expanding resources , 1998 .

[17]  W. Gedroyc Interventional magnetic resonance imaging. , 1997, BJU international.

[18]  W. Kaiser,et al.  A manipulator system for 14‐gauge large core breast biopsies inside a high‐field whole‐body MR scanner , 2003, Journal of magnetic resonance imaging : JMRI.

[19]  W. Kaiser,et al.  Robotic system for biopsy and therapy of breast lesions in a high-field whole-body magnetic resonance tomography unit. , 2000, Investigative radiology.

[20]  K Chinzei,et al.  Towards MRI guided surgical manipulator. , 2001, Medical science monitor : international medical journal of experimental and clinical research.

[21]  E. Atalar,et al.  MR‐trackable intramyocardial injection catheter , 2004, Magnetic resonance in medicine.

[22]  H. K. Charles,et al.  Catheter‐tracking FOV MR fluoroscopy , 1998, Magnetic resonance in medicine.

[23]  Essa Yacoub,et al.  Design of an MRI-compatible robotic stereotactic device for minimally invasive interventions in the breast. , 2004, Journal of biomechanical engineering.

[24]  H Iseki,et al.  Development of an MRI-compatible needle insertion manipulator for stereotactic neurosurgery. , 1995, Journal of image guided surgery.