Identifying the location of odour nuisance emitters using spatial GIS analyses.

The primary objective of the article was to establish the location of odour emitters with the use of spatial GIS analyses. The odour emitter location analysis based on measurements was carried out using QGIS software tools. The algorithm of the procedure was developed by analysing vector elements, including simulated odour streaks (in the form of wedge buffer surfaces) and a regular grid of points needed to determine the presence of a given buffer in a given location. Statistical analysis was performed in ArcGIS software. The detailed aim of the conducted study was to analyse the nuisance of odours from the measurement data on the basis of IDW interpolation and the arrangement of buildings. An innovative element of the developed analysis is the application of the inversed method of fragrance streak propagation. Identifying a streak from the measuring point towards the blowing wind is very likely to determine the approximate location of the odour emitter measured. The described method should provide better results at the location of emitters than the above mentioned methods using interpolation, because of taking into account wind direction and speed. In addition, it is a method that can be applied over a large open area where methods based on simulation and particle propagation would not be efficient or highly impossible to apply due to extensive and complex analysis. It was necessary to conduct field studies in order to meet the main goal, which resulted in sensory evaluation of the intensity of odour nuisance in an urbanised area. Odour concentration tests using field olfactometry with NasalRanger olfactometer were taken.

[2]  M. Holdren,et al.  Development of Emission Factors for Polyethylene Processing. , 1996, Journal of the Air & Waste Management Association.

[3]  P. Dalton,et al.  A Multi-Year Field Olfactometry Study Near a Concentrated Animal Feeding Operation , 2011, Journal of the Air & Waste Management Association.

[4]  Xiang Gao,et al.  Multi-Sensor Integration to Map Odor Distribution for the Detection of Chemical Sources , 2016, Sensors.

[5]  Lester L. Yuan,et al.  Comparison of spatial interpolation methods for the estimation of air quality data , 2004, Journal of Exposure Analysis and Environmental Epidemiology.

[6]  Chunhui Zhang,et al.  Odor emission impact assessment of Zhengwangfen wastewater treatment plant in Beijing , 2016 .

[7]  Michael Brauer,et al.  Application of land use regression to estimate long-term concentrations of traffic-related nitrogen oxides and fine particulate matter. , 2007, Environmental science & technology.

[8]  Mariusz Sołtysik,et al.  Odour Nuisance As a Consequence of Preparation for Circular Economy , 2020 .

[9]  N. Cernansky DIESEL EXHAUST ODOR AND IRRITANTS: A REVIEW , 1983 .

[10]  Simon X. Yang,et al.  Factor analysis of downwind odours from livestock farms , 2007 .

[11]  Alfredo Soldati,et al.  Urban air pollution by odor sources: Short time prediction , 2015 .

[12]  C W GRUBER,et al.  Odor determination techniques for air pollution control. , 1960, Journal of the Air Pollution Control Association.

[13]  Roberto Giua,et al.  Synergistic approaches for odor active compounds monitoring and identification: State of the art, integration, limits and potentialities of analytical and sensorial techniques , 2018, TrAC Trends in Analytical Chemistry.

[14]  Andreas Seidler,et al.  The Use of Biomass for Electricity Generation: A Scoping Review of Health Effects on Humans in Residential and Occupational Settings , 2018, International journal of environmental research and public health.

[15]  Katrijn Van Huffel,et al.  Evaluation of the performance of field olfactometers by selected ion flow tube mass spectrometry , 2015 .

[16]  K. Fukushi,et al.  Considering Water Quality of Urban Rivers from the Perspectives of Unpleasant Odor , 2018 .

[17]  P Baltrenas,et al.  Application of dynamic olfactometry to determine odor concentrations in ambient air , 2013 .

[18]  James A. Nicell,et al.  Assessment and regulation of odour impacts , 2009 .

[19]  Tongbin Chen,et al.  Odor composition analysis and odor indicator selection during sewage sludge composting , 2016, Journal of the Air & Waste Management Association.

[20]  Matthew Thompson,et al.  Odor Concentrations Downwind of Idaho Dairies and Heifer Facilities , 2007 .

[21]  Sarah E. Kemp,et al.  Sensory evaluation: a practical handbook. , 2009 .

[22]  Izabela Sówka,et al.  Metody identyfikacji odorotwórczych gazów emitowanych z obiektów przemysłowych , 2011 .

[23]  Xiang Gao,et al.  Detection and Tracking of an Odor Source in Sensor Networks Using a Reasoning System , 2016 .

[24]  I. Halachmi,et al.  Odorants and malodors associated with land application of biosolids stabilized with lime and coal fly ash. , 2011, Journal of environmental quality.

[25]  J. Namieśnik,et al.  A case study of odour nuisance evaluation in the context of integrated urban planning. , 2018, Journal of environmental management.

[26]  S. Schiffman,et al.  Science of odor as a potential health issue. , 2005, Journal of environmental quality.

[27]  Mihalis Lazaridis,et al.  Dispersion of Odorous Gaseous Compounds Emitted from Wastewater Treatment Plants , 2011 .

[28]  Jian Huang,et al.  Odor source localization algorithms on mobile robots: A review and future outlook , 2019, Robotics Auton. Syst..

[29]  John A. Curtis,et al.  The perception of odor is not a surrogate marker for chemical exposure: a review of factors influencing human odor perception , 2013, Clinical toxicology.

[30]  A. Vigueras-Rodriguez,et al.  Evaluation of Sulfide Control by Air-Injection in Sewer Force Mains: Field and Laboratory Study , 2017 .

[31]  Morten Meilgaard,et al.  Sensory Evaluation Techniques , 2020 .

[32]  I. Croy,et al.  Applied olfactory cognition , 2014, Front. Psychol..

[33]  Michelle L Bell,et al.  The use of ambient air quality modeling to estimate individual and population exposure for human health research: a case study of ozone in the Northern Georgia Region of the United States. , 2006, Environment international.

[34]  Gonzalo Ruiz-Filippi,et al.  Modeling the Odor Generation in WWTP: An Integrated Approach Review , 2014, Water, Air, & Soil Pollution.

[35]  Michael Brauer,et al.  Within-urban variability in ambient air pollution: Comparison of estimation methods , 2008 .

[36]  Sahar Asadi,et al.  Integration of OpenFOAM Flow Simulation and Filament-Based Gas Propagation Models for Gas Dispersion Simulation , 2010 .

[37]  Paul Heeres,et al.  A Review of 20 Years of Standardization of Odor Concentration Measurement by Dynamic Olfactometry in Europe. , 1999, Journal of the Air & Waste Management Association.

[38]  Tien-Fu Lu,et al.  3D framework combining CFD and MATLAB techniques for plume source localization research , 2013 .

[39]  A. Karim,et al.  Modelling reacting localized air pollution using Computational Fluid Dynamics (CFD) , 2011 .

[40]  Lauren Rogers,et al.  Sensory Panel Management : A Practical Handbook for Recruitment, Training and Performance , 2017 .

[41]  J. Namieśnik,et al.  Evaluation of Health Hazard Due to Emission of Volatile Organic Compounds from Various Processing Units of Wastewater Treatment Plant , 2019, International journal of environmental research and public health.

[42]  Qing-Long Han,et al.  A finite-time particle swarm optimization algorithm for odor source localization , 2014, Inf. Sci..

[43]  Dongil Shin,et al.  Source localization for hazardous material release in an outdoor chemical plant via a combination of LSTM-RNN and CFD simulation , 2019, Comput. Chem. Eng..