Novel spirometry based on optical surface imaging.

PURPOSE To evaluate the feasibility of using optical surface imaging (OSI) to measure the dynamic tidal volume (TV) of the human torso during free breathing. METHODS We performed experiments to measure volume or volume change in geometric and deformable phantoms as well as human subjects using OSI. To assess the accuracy of OSI in volume determination, we performed experiments using five geometric phantoms and two deformable body phantoms and compared the values with those derived from geometric calculations and computed tomography (CT) measurements, respectively. To apply this technique to human subjects, an institutional review board protocol was established and three healthy volunteers were studied. In the human experiment, a high-speed image capture mode of OSI was applied to acquire torso images at 4-5 frames per second, which was synchronized with conventional spirometric measurements at 5 Hz. An in-house matlab program was developed to interactively define the volume of interest (VOI), separate the thorax and abdomen, and automatically calculate the thoracic and abdominal volumes within the VOIs. The torso volume change (TV C = ΔVtorso = ΔVthorax + ΔVabdomen) was automatically calculated using full-exhalation phase as the reference. The volumetric breathing pattern (BPv = ΔVthorax/ΔVtorso) quantifying thoracic and abdominal volume variations was also calculated. Under quiet breathing, TVC should equal the tidal volume measured concurrently by a spirometer with a conversion factor (1.08) accounting for internal and external differences of temperature and moisture. Another matlab program was implemented to control the conventional spirometer that was used as the standard. RESULTS The volumes measured from the OSI imaging of geometric phantoms agreed with the calculated volumes with a discrepancy of 0.0% ± 1.6% (range -1.9% to 2.5%). In measurements from the deformable torso/thorax phantoms, the volume differences measured using OSI imaging and CT imaging were 1.2% ± 2.1% (range -0.5% to 3.6%), with a linear regression fitting (slope = 1.02 and R(2) = 0.999). In volunteers, the relative error in OSI tidal volume measurement was -2.2% ± 4.9% (range -9.2% to 4.8%) and a correlation of r = 0.98 was found with spirometric measurement. The breathing pattern values of the three volunteers were substantially different from each other (BPv = 0.15, 0.45, and 0.32). CONCLUSIONS This study demonstrates the feasibility of using OSI to measure breathing tidal volumes and breathing patterns with adequate accuracy. This is the first time that dynamic breathing tidal volume as well as breathing patterns is measured using optical surface imaging. The OSI-observed movement of the entire torso could serve as a new respiratory surrogate in the treatment room during radiation therapy.

[1]  Jie Wei,et al.  Rapid estimation of 4DCT motion-artifact severity based on 1D breathing-surrogate periodicity. , 2014, Medical physics.

[2]  A. Yuan,et al.  TU-F-17A-03: An Analytical Respiratory Perturbation Model for Lung Motion Prediction. , 2014, Medical physics.

[3]  A. Yuan,et al.  TU-F-17A-01: BEST IN PHYSICS (JOINT IMAGING-THERAPY) - An Automatic Toolkit for Efficient and Robust Analysis of 4D Respiratory Motion. , 2014, Medical physics.

[4]  Jason Y. Cheng,et al.  A feasibility study of image registration using volumetrically classified, motion-free bony landmarks in thoracic 4DCT images for image-guided patient setup , 2012 .

[5]  David Sarrut,et al.  Multi-dimensional respiratory motion tracking from markerless optical surface imaging based on deformable mesh registration , 2012, Physics in medicine and biology.

[6]  J. Mechalakos,et al.  Motion monitoring for cranial frameless stereotactic radiosurgery using video-based three-dimensional optical surface imaging. , 2011, Medical physics.

[7]  D. Yan,et al.  Coupling surface cameras with on-board fluoroscopy: a feasibility study. , 2011, Medical physics.

[8]  K. Camphausen,et al.  A novel analytical approach to the prediction of respiratory diaphragm motion based on external torso volume change , 2009, Physics in medicine and biology.

[9]  J. McClelland,et al.  Assessment of two novel ventilatory surrogates for use in the delivery of gated/tracked radiotherapy for non-small cell lung cancer. , 2009, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[10]  Wei Lu,et al.  Quantitative prediction of respiratory tidal volume based on the external torso volume change: a potential volumetric surrogate , 2009, Physics in medicine and biology.

[11]  Cedric X. Yu,et al.  On the sources of drift in a turbine-based spirometer , 2008, Physics in medicine and biology.

[12]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76a). , 2006, Medical physics.

[13]  Jeffrey D Bradley,et al.  Comparison of spirometry and abdominal height as four-dimensional computed tomography metrics in lung. , 2005, Medical physics.

[14]  Sasa Mutic,et al.  Quantitation of the reconstruction quality of a four-dimensional computed tomography process for lung cancer patients. , 2005, Medical physics.

[15]  Kenneth E Rosenzweig,et al.  Tumor Motion Control in the Treatment of Non Small Cell Lung Cancer , 2005, Cancer investigation.

[16]  Harry Keller,et al.  Application of the spirometer in respiratory gated radiotherapy. , 2003, Medical physics.

[17]  Michael B Sharpe,et al.  Initial clinical experience with moderate deep-inspiration breath hold using an active breathing control device in the treatment of patients with left-sided breast cancer using external beam radiation therapy. , 2003, International journal of radiation oncology, biology, physics.

[18]  G. Christensen,et al.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. , 2003, Medical physics.

[19]  Guillermo Sapiro,et al.  Image inpainting , 2000, SIGGRAPH.

[20]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[21]  C. Huntzinger Image Guided Radiation Therapy , 2005 .

[22]  G J Kutcher,et al.  Deep inspiration breath-hold technique for lung tumors: the potential value of target immobilization and reduced lung density in dose escalation. , 1999, International journal of radiation oncology, biology, physics.

[23]  D. Giddon,et al.  TECHNIQUES OF PLETHYSMOGRAPHY. , 1965, Psychophysiology.