A Numerical Study on the Effects of SOFA on NOx Emission Reduction in 500MW Class Sub-bituminous Coal-Fired Boiler

A numerical investigation has been carried out about the performance of a 500MW class tangentially coal-fired boiler, focusing on the optimization of separated overfire air (SOFA) position to reduce NOx emission. For this purpose, a comprehensive combination of NOx chemistry models has been employed in the numerical simulation of a particle-laden flow along with solid fuel combustion and heat and mass transfer. A reasonable agreement has been shown in baseline cases for predicted operational parameters compared with experimental data measured in the boiler. A further SOFA calculation has been made to obtain optimum elevation and position of SOFA port. Additionally, clarifying on the effect of SOFA on NOx emission has been carried out in the coal-fired boiler. As a result, this paper is valuable to provide an information about the optimum position of SOFA and the mechanism by which the SOFA would affect NOx emission.

[1]  Philip J. Smith,et al.  Modeling Effects of Soot and Turbulence-Radiation Coupling on Radiative Transfer in Turbulent Gaseous Combustion , 1995 .

[2]  L. Douglas Smoot,et al.  Coal Combustion and Gasification , 1985 .

[3]  Luis I. Díez,et al.  Numerical investigation of NOx emissions from a tangentially-fired utility boiler under conventional and overfire air operation , 2008 .

[4]  P. J. Smith,et al.  Three-dimensional discrete-ordinates modeling of radiative transfer in a geometrically complex furnace , 1993 .

[5]  Mitchell D. Smooke,et al.  Reduced Kinetic Mechanisms and Asymptotic Approximations for Methane-Air Flames: A Topical Volume , 1991 .

[6]  Francisco Cadavid,et al.  Coal combustion modelling of large power plant, for NOx abatement , 2007 .

[7]  Ronald K. Hanson,et al.  Shock tube determination of the rate coefficient for the reaction N2+O→NO+N , 1979 .

[8]  S. C. Hill,et al.  Modeling of nitrogen oxides formation and destruction in combustion systems , 2000 .

[9]  L. Douglas Smoot,et al.  Model for pulverized coal-fired reactors , 1981 .

[10]  B. Launder,et al.  Mathematical Models of turbulence , 1972 .

[11]  Mathematical modelling of fluid flow and mixing in tangentially fired furnaces , 1985 .

[12]  Shien Hui,et al.  NOx emission and thermal efficiency of a 300 MWe utility boiler retrofitted by air staging , 2009 .

[13]  S. Turns An Introduction to Combustion: Concepts and Applications , 2000 .

[14]  A. Sarofim,et al.  Coal devolatilization at high temperatures , 1977 .