Inelastic performance of screw-connected cold-formed steel strap-braced walls

Cold-formed steel, screw-connected strap-braced walls (15 specimens, 2.44 m × 2.44 m each), designed following a capacity-based approach, were tested to evaluate their performance in the inelastic range of behaviour. Gross cross-section yielding of the tension braces was the specified failure mode in the design procedure. Extended tracks and additional shear anchors were installed, such that inelastic deformations would be limited to tension yielding of the braces. Walls without extended tracks were able to reach their yield level; however, damage to other frame elements occurred, thus reducing the ductility level that was attained. Cyclically loaded walls (0.5 Hz) with track extensions showed that wall performance is also dependent on the strain rate experienced by the braces. An Fu / Fy ratio greater than 1.2 is necessary to limit the possibility of brace fracture under seismic loading. Preliminary force modification factors, Rd = 2.0 and Ro = 1.3, are recommended for walls designed and detailed to achi...

[1]  Reynaud Serrette,et al.  Shear Resistance of Gypsum-Sheathed Light-Gauge Steel Stud Walls , 1996 .

[2]  D Dubina,et al.  PERFORMANCE OF WALL-STUD COLD-FORMED SHEAR PANELS UNDER MONOTONIC AND CYCLIC LOADING PART I: EXPERIMENTAL RESEARCH , 2004 .

[3]  Melvin J. Dubnick Army Corps of Engineers , 1998 .

[4]  Moon Sung Lee,et al.  Shaketable tests of a cold-formed steel shear panel , 2006 .

[5]  W. J. Hall,et al.  Earthquake spectra and design , 1982 .

[6]  Adrian M. Chandler,et al.  Lateral Behavior of Plasterboard-Clad Residential Steel Frames , 1999 .

[7]  Robert Tremblay,et al.  Seismic force modification factors for the proposed 2005 edition of the National Building Code of Canada , 2003 .

[8]  Emad Gad,et al.  Lateral performance of cold-formed steel-framed domestic structures , 1999 .

[9]  Colin A. Rogers,et al.  Inelastic performance of cold-formed steel strap braced walls , 2007 .

[10]  Y. S. Tian,et al.  Racking Strength and Stiffness of Cold-Formed Steel Wall Frames , 2004 .

[11]  Adrian M. Chandler,et al.  Earthquake ductility and overstrength in residential structures , 1999 .

[12]  V. Avanessian,et al.  Shear Wall Resistance of Lightgage Steel Stud Wall Systems , 1990 .

[13]  Antonio Rodríguez-Ferran,et al.  Experimental testing of joints for seismic design of lightweight structures. Part 1. Screwed joints in straps , 2006 .

[14]  Antonio Rodríguez-Ferran,et al.  Hysteretic modelling of x-braced shear walls , 2005 .

[15]  Luis Ibarra,et al.  Development of a testing protocol for woodframe structures , 1999 .

[16]  N. Null Minimum Design Loads for Buildings and Other Structures , 2003 .

[17]  Robert Tremblay,et al.  SEISMIC IMPACT LOADING IN INELASTIC TENSION‐ONLY CONCENTRICALLY BRACED STEEL FRAMES: MYTH OR REALITY? , 1996 .