MRI artifacts and correction strategies

Artifacts appear in MRI for a variety of reasons. Potential sources of artifacts include nonideal hardware characteristics, intrinsic tissue properties and biological behavior, assumptions underlying the data acquisition and image reconstruction process, and poor choice of scanning parameters. Careful study design and scanning protocols can prevent certain artifacts from occurring, but some are unavoidable. Numerous correction methods have been developed to mitigate the corruptive effects of artifacts and improve image diagnostic quality. These methods include special pulse sequence designs, improved scanning procedures and equipment, and advanced postprocessing algorithms. Recognizing artifacts and understanding their underlying causes are important when interpreting images and choosing a correction approach.

[1]  H. Carr STEADY-STATE FREE PRECESSION IN NUCLEAR MAGNETIC RESONANCE , 1958 .

[2]  P. Mansfield Multi-planar image formation using NMR spin echoes , 1977 .

[3]  W. Edelstein,et al.  Spin warp NMR imaging and applications to human whole-body imaging. , 1980, Physics in medicine and biology.

[4]  D. Twieg The k-trajectory formulation of the NMR imaging process with applications in analysis and synthesis of imaging methods. , 1983, Medical physics.

[5]  M. S. Silver,et al.  Highly selective {π}/{2} and π pulse generation , 1984 .

[6]  D. Twieg Acquistion and Accuracy in Rapid NMR Imaging Methods , 1985, Magnetic resonance in medicine.

[7]  C. Ahn,et al.  High-Speed Spiral-Scan Echo Planar NMR Imaging-I , 1986, IEEE Transactions on Medical Imaging.

[8]  E M Haacke,et al.  Improving MR image quality in the presence of motion by using rephasing gradients. , 1987, AJR. American journal of roentgenology.

[9]  D N Firmin,et al.  The application of phase shifts in NMR for flow measurement , 1990, Magnetic resonance in medicine.

[10]  R L Ehman,et al.  Flow artifact reduction in MRI: A review of the roles of gradient moment nulling and spatial presaturation , 1990, Magnetic resonance in medicine.

[11]  J. Pauly,et al.  A homogeneity correction method for magnetic resonance imaging with time-varying gradients. , 1991, IEEE transactions on medical imaging.

[12]  Michael Garwood,et al.  Symmetric pulses to induce arbitrary flip angles with compensation for rf inhomogeneity and resonance offsets , 1991 .

[13]  G H Glover,et al.  Projection Reconstruction Techniques for Reduction of Motion Effects in MRI , 1992, Magnetic resonance in medicine.

[14]  Douglas C. Noll,et al.  Deblurring for non‐2D fourier transform magnetic resonance imaging , 1992, Magnetic resonance in medicine.

[15]  R M Henkelman,et al.  K‐space description for MR imaging of dynamic objects , 1993, Magnetic resonance in medicine.

[16]  R. Ordidge,et al.  Correction of motional artifacts in diffusion-weighted MR images using navigator echoes. , 1994, Magnetic resonance imaging.

[17]  J C Gore,et al.  Analysis and correction of motion artifacts in diffusion weighted imaging , 1994, Magnetic resonance in medicine.

[18]  D. Teichberg,et al.  Local histogram correction of MRI spatially dependent image pixel intensity nonuniformity , 1996, Journal of magnetic resonance imaging : JMRI.

[19]  J. Schenck The role of magnetic susceptibility in magnetic resonance imaging: MRI magnetic compatibility of the first and second kinds. , 1996, Medical physics.

[20]  X. Hu,et al.  Simulated phase evolution rewinding (SPHERE): A technique for reducing B0 inhomogeneity effects in MR images , 1997, Magnetic resonance in medicine.

[21]  M. McConnell,et al.  Prospective navigator correction of image position for coronary MR angiography. , 1997, Radiology.

[22]  H. Wen,et al.  Simulation ofB1Field Distribution and Intrinsic Signal-to-Noise in Cardiac MRI as a Function of Static Magnetic Field , 1997 .

[23]  A Macovski,et al.  Multifrequency interpolation for fast off‐resonance correction , 1997, Magnetic resonance in medicine.

[24]  John M. Pauly,et al.  Improved automatic off‐resonance correction without a field map in spiral imaging , 1997, Magnetic resonance in medicine.

[25]  N J Pelc,et al.  Concomitant gradient terms in phase contrast MR: Analysis and correction , 1998, Magnetic resonance in medicine.

[26]  E M Stokely,et al.  A novel k‐space trajectory measurement technique , 1998, Magnetic resonance in medicine.

[27]  K F King,et al.  Concomitant gradient field effects in spiral scans , 1999, Magnetic resonance in medicine.

[28]  D Atkinson,et al.  Automatic compensation of motion artifacts in MRI , 1999, Magnetic resonance in medicine.

[29]  Hermann Schomberg,et al.  Off-resonance correction of MR images , 1999, IEEE Transactions on Medical Imaging.

[30]  J. Pipe Motion correction with PROPELLER MRI: Application to head motion and free‐breathing cardiac imaging , 1999, Magnetic resonance in medicine.

[31]  Bostjan Likar,et al.  Retrospective correction of MR intensity inhomogeneity by information minimization , 2000, IEEE Transactions on Medical Imaging.

[32]  Graham A Wright,et al.  Variable‐density adaptive imaging for high‐resolution coronary artery MRI , 2002, Magnetic resonance in medicine.

[33]  P. Börnert,et al.  Novel prospective respiratory motion correction approach for free‐breathing coronary MR angiography using a patient‐adapted affine motion model , 2003, Magnetic resonance in medicine.

[34]  Peter Boesiger,et al.  Cardiac SSFP imaging at 3 Tesla , 2004, Magnetic resonance in medicine.

[35]  P. Batchelor,et al.  Matrix description of general motion correction applied to multishot images , 2005, Magnetic resonance in medicine.

[36]  Dwight G Nishimura,et al.  Spiral balanced steady‐state free precession cardiac imaging , 2005, Magnetic resonance in medicine.

[37]  Reza Nezafat,et al.  B1‐insensitive T2 preparation for improved coronary magnetic resonance angiography at 3 T , 2006, Magnetic resonance in medicine.

[38]  Oliver Speck,et al.  Advantages and limitations of prospective head motion compensation for MRI using an optical motion tracking device. , 2006, Academic radiology.

[39]  Richard B. Buxton,et al.  A Primer on Functional Magnetic Resonance Imaging , 2007, Neuropsychology Review.

[40]  Krishna S Nayak,et al.  Wideband SSFP: Alternating repetition time balanced steady state free precession with increased band spacing , 2007, Magnetic resonance in medicine.

[41]  Pascal Spincemaille,et al.  Kalman filtering for real‐time navigator processing , 2008, Magnetic resonance in medicine.

[42]  K. Nayak,et al.  B  1+ compensation in 3T cardiac imaging using short 2DRF pulses , 2008, Magnetic resonance in medicine.

[43]  Andrew C Larson,et al.  Comparison of self‐gated cine MRI retrospective cardiac synchronization algorithms , 2008, Journal of magnetic resonance imaging : JMRI.

[44]  J. Felblinger,et al.  Generalized Reconstruction by Inversion of Coupled Systems (GRICS) applied to free‐breathing MRI , 2008, Magnetic resonance in medicine.

[45]  Weitian Chen,et al.  Semiautomatic off‐resonance correction in spiral imaging , 2008, Magnetic resonance in medicine.

[46]  Jie Deng,et al.  Multishot diffusion‐weighted SPLICE PROPELLER MRI of the abdomen , 2008, Magnetic resonance in medicine.

[47]  Craig H Meyer,et al.  Estimation of k‐space trajectories in spiral MRI , 2009, Magnetic resonance in medicine.

[48]  Klaas P Pruessmann,et al.  A transmit/receive system for magnetic field monitoring of in vivo MRI , 2009, Magnetic resonance in medicine.

[49]  Krishna S Nayak,et al.  Improved 3‐Tesla cardiac cine imaging using wideband , 2010, Magnetic resonance in medicine.