Combined effects of implant insertion depth and alveolar bone quality on periimplant bone strain induced by a wide-diameter, short implant and a narrow-diameter, long implant.

STATEMENT OF PROBLEM Strain levels in periimplant bone are affected by implant dimensions, bone quality, and implant insertion depth, resulting in different bone maintenance characteristics. PURPOSE The purpose of this study was to evaluate the biomechanical response of the jaw bone to a wide-diameter, short (WDS) implant, and a narrow-diameter, long (NDL) implant for various simulated clinical scenarios. MATERIAL AND METHODS The finite element method was used to evaluate periimplant bone strain distribution for 5 × 6-mm (WDS) and 3.5 × 10.7-mm (NDL) implants. A 3-dimensional segment of the mandible was constructed from a computerized tomography image of the premolar region. Occlusal force was simulated by applying a 100-N oblique load on the abutment. Bone strain distributions for 5 different implant insertion depths and 2 different levels of alveolar bone quality were evaluated. RESULTS For an NDL implant, approximately 60% to 80% of the bone volume surrounding the implant was subjected to 200-1000 μstrain (μɛ), and 15% to 35% was subjected to 1000-3000 μɛ, regardless of the alveolar bone quality. For a WDS implant, the bone volume subjected to 1000-3000 μɛ increased, and the bone volume subjected to 200-1000 μɛ decreased in lower quality alveolar bone. For both implant types, bone volume experiencing strain levels less than 200 μɛ, and/or greater than 3000 μɛ, was predicted to be relatively small. CONCLUSIONS In general, the thread design promoted relatively high strain around the thread tips, and the bone inside grooves was less strained. A more even and higher strain distribution in the periimplant bone was generated by the WDS implant as compared to the NDL implant. Regardless of the implant dimensions and simulated clinical scenarios, the development of high strain in the alveolar region was inevitable. Strain levels in periimplant bone were reduced as the insertion depth of the implant was increased.

[1]  D Lundgren,et al.  Occlusal force pattern in dentitions with mandibular implant-supported fixed cantilever prostheses occluded with complete dentures. , 1989, The International journal of oral & maxillofacial implants.

[2]  Marco Ghisolfi,et al.  Long-term survival and success of oral implants in the treatment of full and partial arches: a 7-year prospective study with the ITI dental implant system. , 2004, The International journal of oral & maxillofacial implants.

[3]  L. Cárdenas-Camarena Managing the Mammary Gland Infiltrated With Foreign Substances: Different Surgical Alternatives , 2009, Annals of plastic surgery.

[4]  G. Sprotte Statement of Problem , 1985 .

[5]  P. Branemark,et al.  Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. , 1977, Scandinavian journal of plastic and reconstructive surgery. Supplementum.

[6]  A. Garden,et al.  Water bolus for electron irradiation of the ear canal. , 1995, International journal of radiation oncology, biology, physics.

[7]  S. Winkler Denture base resins. , 1984, Dental clinics of North America.

[8]  Niklaus P. Lang,et al.  Periodontal tissues and their counterparts around endosseous implants [corrected and republished with original paging, article orginally printed in Clin Oral Implants Res 1991 Jan-Mar;2(1):1-19]. , 1991 .

[9]  Giuseppe Vairo,et al.  The influence of implant diameter and length on stress distribution of osseointegrated implants related to crestal bone geometry: a three-dimensional finite element analysis. , 2008, The Journal of prosthetic dentistry.

[10]  James Laney Williams,et al.  Comparative evaluation of implant designs: influence of diameter, length, and taper on strains in the alveolar crest. A three-dimensional finite-element analysis. , 2005, Clinical oral implants research.

[11]  Haruka Kusakari,et al.  Influence of implant design and bone quality on stress/strain distribution in bone around implants: a 3-dimensional finite element analysis. , 2003, The International journal of oral & maxillofacial implants.

[12]  P. Tanner,et al.  A surgical guide for craniofacial implant placement for an implant-retained auricular prosthesis. , 2010, The Journal of prosthetic dentistry.

[13]  R. Truhlar,et al.  Bone quality and implant design-related outcomes through stage II surgical uncovering of Spectra-System root form implants. , 1997, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[14]  Li Shi,et al.  A mathematical model for simulating the bone remodeling process under mechanical stimulus. , 2007, Dental materials : official publication of the Academy of Dental Materials.

[15]  S. Müftü,et al.  Mechanics of the tapered interference fit in dental implants. , 2003, Journal of biomechanics.

[16]  R. F. Morgan,et al.  Silicone Gel Implants in Breast Augmentation and Reconstruction , 2007, Annals of Plastic Surgery.

[17]  O. Bahat Osseointegrated implants in the maxillary tuberosity: report on 45 consecutive patients. , 1993, The International journal of oral & maxillofacial implants.

[18]  A. Siddiqui,et al.  Wide diameter implants: indications, considerations and preliminary results over a two-year period. , 1994, Australian prosthodontic journal.

[19]  Holmes Dc,et al.  Influence of bone quality on stress distribution for endosseous implants. , 1997 .

[20]  D. Lundgren,et al.  Interfering occlusal contacts and distribution of chewing and biting forces in dentitions with fixed cantilever prostheses. , 1987, The Journal of prosthetic dentistry.

[21]  Georges Limbert,et al.  Trabecular bone strains around a dental implant and associated micromotions--a micro-CT-based three-dimensional finite element study. , 2010, Journal of biomechanics.

[22]  S. Alfano,et al.  Fabrication of a craniofacial implant surgical and treatment planning guide. , 2005, The Journal of prosthetic dentistry.

[23]  P. Pröschel,et al.  In vivo forces on implants influenced by occlusal scheme and food consistency. , 2003, The International journal of prosthodontics.

[24]  Alfonso Venturelli A modified surgical protocol for placing implants in the maxillary tuberosity: clinical results at 36 months after loading with fixed partial dentures. , 1996, The International journal of oral & maxillofacial implants.

[25]  P Missika,et al.  Optimal implant stabilization in low density bone. , 2001, Clinical oral implants research.

[26]  H. Grootenboer,et al.  Adaptive bone-remodeling theory applied to prosthetic-design analysis. , 1987, Journal of biomechanics.

[27]  H. Haanaes,et al.  A prospective clinical study evaluating the safety and effectiveness of narrow-diameter threaded implants in the anterior region of the maxilla. , 2001, The International journal of oral & maxillofacial implants.

[28]  C. Misch Contemporary Implant Dentistry , 1993 .

[29]  Hsuan-Yu Chou,et al.  Predictions of bone remodeling around dental implant systems. , 2008, Journal of biomechanics.

[30]  M. McCracken,et al.  Histomorphological evaluation of loaded plate-form and root-form implants in Macaca mulatta monkeys. , 2002, Clinical oral implants research.

[31]  J. Webster Encyclopedia of Medical Devices and Instrumentation , 1988 .

[32]  T. Albrektsson,et al.  The Branemark Osseointegrated Implant , 1989 .

[33]  A. Maalhagh-Fard,et al.  Retrieval of a stripped abutment screw: a clinical report. , 2010, The Journal of prosthetic dentistry.

[34]  D. Sarment,et al.  Five-mm-diameter implants without a smooth surface collar: report on 98 consecutive placements. , 1999, The International journal of oral & maxillofacial implants.

[35]  James S Hodges,et al.  Correlations between physical properties of jawbone and dental implant initial stability. , 2009, The Journal of prosthetic dentistry.

[36]  S. Hansson,et al.  The implant thread as a retention element in cortical bone: the effect of thread size and thread profile: a finite element study. , 2003, Journal of biomechanics.

[37]  B. Kesim,et al.  The effect of primers on shear bond strength of acrylic resins to different types of metals. , 2010, The Journal of prosthetic dentistry.

[38]  S. Aquilino,et al.  Cantilever and implant biomechanics: a review of the literature. Part 1. , 1994, Journal of prosthodontics : official journal of the American College of Prosthodontists.

[39]  D P Fyhrie,et al.  Trabecular bone density and loading history: regulation of connective tissue biology by mechanical energy. , 1987, Journal of biomechanics.

[40]  W. R. Powell,et al.  Dosimetry of a silicone breast prosthesis. , 1980, Radiology.

[41]  D Buser,et al.  Osseointegration: a reality. , 1998, Periodontology 2000.

[42]  M Davarpanah,et al.  Wide-diameter implants: new concepts. , 2001, The International journal of periodontics & restorative dentistry.

[43]  H. F. Morris,et al.  A new implant designed to maximize contact with trabecular bone: survival to 18 months. , 2001, The Journal of oral implantology.

[44]  M. Sevimay,et al.  Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown. , 2005, The Journal of prosthetic dentistry.

[45]  H. Frost Bone “mass” and the “mechanostat”: A proposal , 1987, The Anatomical record.

[46]  F. Renouard,et al.  Impact of implant length and diameter on survival rates. , 2006, Clinical oral implants research.

[47]  Wei Li,et al.  Dental implant induced bone remodeling and associated algorithms. , 2009, Journal of the mechanical behavior of biomedical materials.

[48]  W. Mendenhall,et al.  Radiation effects on the auditory and vestibular systems. , 2009, Otolaryngologic clinics of North America.

[49]  P I Brånemark,et al.  A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. , 1981, International journal of oral surgery.

[50]  D. Lundgren,et al.  Occlusal interferences and cantilever joint stress in implant-supported prostheses occluding with complete dentures. , 1990, The International journal of oral & maxillofacial implants.

[51]  D C Holmes,et al.  Influence of bone quality on stress distribution for endosseous implants. , 1997, The Journal of oral implantology.

[52]  D van Steenberghe,et al.  Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system. , 1992, Clinical oral implants research.

[53]  Rui-Feng Wang,et al.  The dynamic natures of implant loading. , 2009, The Journal of prosthetic dentistry.

[54]  M. Chiapasco,et al.  Implant-retained mandibular overdentures with immediate loading: a 3- to 8-year prospective study on 328 implants. , 2003, Clinical implant dentistry and related research.

[55]  Dinçer Bozkaya,et al.  Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis. , 2004, The Journal of prosthetic dentistry.

[56]  P. Branemark,et al.  An experimental and clinical study of osseointegrated implants penetrating the nasal cavity and maxillary sinus. , 1984, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[57]  Yasuhiro Tanimoto,et al.  Influence of cortical bone quality on stress distribution in bone around dental implant. , 2005, Dental materials journal.

[58]  G Van der Perre,et al.  The influence of bone mechanical properties and implant fixation upon bone loading around oral implants. , 1998, Clinical oral implants research.

[59]  K. Hogstrom Treatment planning in electron beam therapy. , 1991, Frontiers of radiation therapy and oncology.