Comparative study of straight and spiral earth air tunnel heat exchanger system operated in cooling and heating modes

Thermal performance of Earth Air Tunnel Heat Exchanger (EATHE) system is found to be highly dependent on thermal properties of soil and soil with poor thermal properties require longer buried pipe for desired heat exchange between air and sub-soil. In densely populated country like India, EATHE systems are rarely used due to the limited ground space (higher aspect ratio in terms of length) in most of the residential and commercial applications. Therefore, in this paper, problem of space limitation for the installation of straight EATHE system is attempted by proposing new spiral shaped EATHE system. The developed EATHE systems were used to determine cooling and heating potential individually and COP were 5.94 and 6.24 in summer; 1.92 and 2.11 in winter for straight and spiral respectively. A transient numerical model has been developed to investigate the performance of both systems. The COP were 4.23 and 4.48 in summer; 5.0 and 5.16 in winter for straight and spiral respectively. The experimental and numerical results suggested that the thermal performance of these two systems are comparable can be interchanged based on available site conditions.

[1]  Anuj Mathur,et al.  Numerical investigation of the performance and soil temperature recovery of an EATHE system under intermittent operations , 2016 .

[2]  Jyotirmay Mathur,et al.  Investigation of soil thermal saturation and recovery under intermittent and continuous operation of EATHE , 2015 .

[3]  Bo Nordell,et al.  Using Fouggara for Heating and Cooling Buildings in Sahara , 2011 .

[4]  Xu Zhang,et al.  Thermal performance and ground temperature of vertical pile-foundation heat exchangers: A case study , 2008 .

[5]  Guohui Gan,et al.  Experimental measurement and numerical simulation of horizontal-coupled slinky ground source heat exchangers , 2010 .

[6]  Jyotirmay Mathur,et al.  CFD analysis of EATHE system under transient conditions for intermittent operation , 2015 .

[7]  Michele De Carli,et al.  Analysis of short helical and double U-tube borehole heat exchangers: A simulation-based comparison , 2013 .

[8]  Jyotirmay Mathur,et al.  Performance analysis of earth–pipe–air heat exchanger for summer cooling , 2010 .

[9]  N. K. Bansal,et al.  Temperature distribution inside ground for various surface conditions , 1981 .

[10]  Thierry Boulard,et al.  Heat and water vapour transfer in a greenhouse with an underground heat storage system part I. Experimental results , 1989 .

[11]  Jyotirmay Mathur,et al.  Performance analysis of earth–pipe–air heat exchanger for winter heating , 2009 .

[12]  Hikari Fujii,et al.  NUMERICAL MODELING OF SLINKY-COIL HORIZONTAL GROUND HEAT EXCHANGERS , 2012 .

[13]  Hikari Fujii,et al.  Numerical simulation and sensitivity study of double-layer Slinky-coil horizontal ground heat exchangers , 2013 .

[14]  Jyotirmay Mathur,et al.  Transient effect of soil thermal diffusivity on performance of EATHE system , 2015 .

[15]  Onder Ozgener,et al.  Determining the optimal design of a closed loop earth to air heat exchanger for greenhouse heating b , 2011 .

[16]  Thierry Boulard,et al.  Heat and water vapour transfer in a greenhouse with an underground heat storage system part II. Model , 1989 .

[17]  S. Thepa,et al.  Cooling performance and condensation evaluation of horizontal earth tube system for the tropical greenhouse , 2013 .

[18]  Arnold Janssens,et al.  Passive cooling in a low-energy office building , 2005 .

[19]  Ursula Eicker,et al.  Potential of geothermal heat exchangers for office building climatisation , 2009 .