Thin film platinum cuff electrodes for neurostimulation: in vitro approach of safe neurostimulation parameters.

Thin film technology takes more and more importance in the development of biomedical devices dedicated to functional neurostimulation. Our research about the design of implant neurostimulating electrode is oriented toward thin film cuff electrodes based on a polyimide substrate covered by a chromium/gold/Pt film. The chromium/gold sputtered film serves as adhesion layer and current collector whereas platinum acts as an electrochemical actuator. The electrode surface has been designed to obey safe stimulation criteria (i.e. chemically inert noble metal, low electrode-electrolyte impedance, high electrochemical reversibility, high corrosion stability). The electrochemical behaviour of such platinum electrodes has been assessed and compared to a foil of platinum. Extensive in vitro characterisations of the both electrode types were carried out using AFM, SEM and electrochemical techniques. The role of enhanced surface roughness enabling high double layer capacitances to be achieved was clearly highlighted. The obtained results are discussed, with particular reference to thin film electrodes stability under in vitro electrical stimulation in NaCl 0.9% (physiological serum). Therefore, these thin film devices showed reversible PtOH formation and decomposition making them potentially attractive for the fabrication of implant stimulation cuff electrodes.

[1]  W.L.C. Rutten,et al.  Sensitivity and selectivity of intraneural stimulation using a silicon electrode array , 1991, IEEE Transactions on Biomedical Engineering.

[2]  M Hyland,et al.  Surface modification of thin film gold electrodes for improved in vivo performance , 1996 .

[3]  R. Stein,et al.  Neural prostheses : replacing motor function after disease or disability , 1992 .

[4]  P. E. K. Donaldson,et al.  When are actively balanced biphasic (‘Lilly’) stimulating pulses necessary in a neurological prosthesis? I Historical background; Pt resting potential;Q studies , 2006, Medical and Biological Engineering and Computing.

[5]  J. R. Hughes,et al.  Brief, noninjurious electric waveform for stimulation of the brain. , 1955, Science.

[6]  Warren M. Grill,et al.  Stimulus waveforms for selective neural stimulation , 1995 .

[7]  P. Delahay,et al.  Advances in Electrochemistry and Electrochemical Engineering , 1964 .

[8]  H. Angerstein-Kozlowska,et al.  The real condition of oxidized pt electrodes , 1973 .

[9]  B. Conway,et al.  Chloride-ion effects on the reversible and irreversible surface oxidation processes at Pt electrodes, and on the growth of monolayer oxide films at Pt , 1982 .

[10]  T Stieglitz,et al.  Characterization and optimization of microelectrode arrays for in vivo nerve signal recording and stimulation. , 1997, Biosensors & bioelectronics.

[11]  M. J. Weaver,et al.  Periodic Trends in Monoatomic Chemisorbate Bonding on Platinum-Group and Other Noble-Metal Electrodes As Probed by Surface-Enhanced Raman Spectroscopy , 2000 .

[12]  D. Williams,et al.  Biocompatibility of implant materials , 1976 .

[13]  H. Angerstein-Kozlowska,et al.  The real condition of electrochemically oxidized platinum surfaces , 1973 .

[14]  W. Grill,et al.  Selective control of muscle activation with a multipolar nerve cuff electrode , 1993, IEEE Transactions on Biomedical Engineering.