Accuracy in computer-aided implant surgery--a review.

The objective of this article was to review the different factors and limitations influencing the accuracy of computer-aided implant surgery. In vitro and in vivo accuracy studies of articles and congress proceedings were examined. Similar results using bur tracking as well as image-guided template production techniques have been reported, and both methods allow for precise positioning of dental implants. Compared to the conventional technique, this sophisticated technology requires substantially more financial investment and effort (computerized tomographic imaging, fabrication of a registration template, intraoperative referencing for bur tracking, or image-guided manufacturing of a surgical template) but appears superior on account of its potential to eliminate possible manual placement errors and to systematize reproducible treatment success. The potential for the protection of critical anatomic structures and the esthetic and functional advantages of prosthodontic-driven implant positioning must also be considered. However, long-term clinical studies are necessary to confirm the value of this strategy and to justify the additional radiation dose, effort, and costs.

[1]  David P Sarment,et al.  Stereolithographic surgical templates for placement of dental implants in complex cases. , 2003, The International journal of periodontics & restorative dentistry.

[2]  Lewis S Benjamin,et al.  The evolution of multiplanar diagnostic imaging: predictable transfer of preoperative analysis to the surgical site. , 2002, The Journal of oral implantology.

[3]  Paul Suetens,et al.  A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. , 2002, The International journal of oral & maxillofacial implants.

[4]  Franz Kainberger,et al.  Computer-aided placement of endosseous oral implants in patients after ablative tumour surgery: assessment of accuracy. , 2003, Clinical oral implants research.

[5]  Robert J. Maciunas,et al.  Registration of head volume images using implantable fiducial markers , 1997, IEEE Transactions on Medical Imaging.

[6]  H F Morris,et al.  Long-term assessment (5 to 71 months) of endosseous dental implants placed in the augmented maxillary sinus. , 2000, Annals of periodontology.

[7]  Gwen Swennen,et al.  Navigated vs. conventional implant insertion for maxillary single tooth replacement. , 2004, Clinical oral implants research.

[8]  P F van der Stelt,et al.  The radiographic assessment of implant patients: decision-making criteria. , 2001, The International journal of oral & maxillofacial implants.

[9]  T Suetsugu,et al.  Accurate presurgical determination for implant placement by using computerized tomography scan. , 1996, The Journal of prosthetic dentistry.

[10]  Reinhilde Jacobs,et al.  Preoperative radiologic planning of implant surgery in compromised patients. , 2003, Periodontology 2000.

[11]  M. S. Schwarz,et al.  Computed tomography: Part I. Preoperative assessment of the mandible for endosseous implant surgery. , 1987, The International journal of oral & maxillofacial implants.

[12]  G A Niznick,et al.  Bending overload and implant fracture: a retrospective clinical analysis. , 1996, The International journal of oral & maxillofacial implants.

[13]  Kevin C Kopp,et al.  Predictable implant placement with a diagnostic/surgical template and advanced radiographic imaging. , 2003, The Journal of prosthetic dentistry.

[14]  Franz Kainberger,et al.  Computer-enhanced stereoscopic vision in a head-mounted display for oral implant surgery. , 2002, Clinical oral implants research.

[15]  Reinhilde Jacobs,et al.  Imaging technique selection for the preoperative planning of oral implants: a review of the literature. , 2002, Clinical implant dentistry and related research.

[16]  D A Kaiser,et al.  Surgical guide for dental implant placement. , 2000, The Journal of prosthetic dentistry.

[17]  P Suetens,et al.  Computer-assisted planning of oral implant surgery: a three-dimensional approach. , 1996, The International journal of oral & maxillofacial implants.

[18]  A B Reiskin,et al.  Implant imaging. Status, controversies, and new developments. , 1998, Dental clinics of North America.

[19]  L A Weinberg,et al.  Three-Dimensional Guidance System for Implant Insertion: Part I , 1998, Implant dentistry.

[20]  A Kawamata,et al.  Three-dimensional computed tomography imaging in dentistry. , 2000, Dental clinics of North America.

[21]  Olva Odium A method of eliminating streak artifacts from metallic dental restorations in CTs of head and neck cancer patients. , 2001 .

[22]  R A Solow Simplified radiographic-surgical template for placement of multiple, parallel implants. , 2001, The Journal of prosthetic dentistry.

[23]  Max Heiland,et al.  Indications and limitations of intraoperative navigation in maxillofacial surgery. , 2004, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[24]  C M Stanford,et al.  Biomechanical and Functional Behavior of Implants , 1999, Advances in dental research.

[25]  Y C Ku,et al.  Fabrication of a radiographic and surgical stent for implants with a vacuum former. , 2000, The Journal of prosthetic dentistry.

[26]  Michael Klein Implant surgery using customized surgical templates: the Compu-Guide Surgical Template System. Interview. , 2002, Dental implantology update.

[27]  Kostas Tsiklakis,et al.  Clinical and radiographic comparison of three regenerative procedures in the treatment of intrabony defects. , 2004, The International journal of periodontics & restorative dentistry.

[28]  M W Vannier,et al.  3D volume rendering using multislice CT for dental implants. , 2002, Dento maxillo facial radiology.

[29]  D M Almog,et al.  Fabrication of imaging and surgical guides for dental implants. , 2001, The Journal of prosthetic dentistry.

[30]  M S Schwarz,et al.  Computed tomography: Part II. Preoperative assessment of the maxilla for endosseous implant surgery. , 1987, The International journal of oral & maxillofacial implants.

[31]  Philippe B Tardieu,et al.  Computer-assisted implant placement. A case report: treatment of the mandible. , 2003, The International journal of oral & maxillofacial implants.

[32]  Wolfgang Birkfellner,et al.  Computer-enhanced stereoscopic vision in a head-mounted operating binocular. , 2003, Physics in medicine and biology.

[33]  Rudolf Seemann,et al.  Computer-aided navigation in dental implantology: 7 years of clinical experience. , 2004, Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons.

[34]  Guy Marchal,et al.  An image-guided planning system for endosseous oral implants , 1998, IEEE Transactions on Medical Imaging.

[35]  G Wang,et al.  Three-dimensional dental imaging by spiral CT. A progress report. , 1997, Oral surgery, oral medicine, oral pathology, oral radiology, and endodontics.

[36]  Tim C. Lueth,et al.  The precision of the RoboDent system — an in vitro study , 2002 .

[37]  J A Hobkirk,et al.  The influence of mandibular deformation, implant numbers, and loading position on detected forces in abutments supporting fixed implant superstructures. , 1998, The Journal of prosthetic dentistry.

[38]  Tim Lüth,et al.  Accuracy of an image-guided system for oral implantology , 2001, CARS.

[39]  Jay B. West,et al.  The distribution of target registration error in rigid-body point-based registration , 2001, IEEE Transactions on Medical Imaging.

[40]  Joachim Mühling,et al.  Laser-scan-based navigation in cranio-maxillofacial surgery. , 2003, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[41]  Carlo Maiorana,et al.  Maxillary and mandibular bone reconstruction with hip grafts and implants using Frialit-2 implants. , 2002, The International journal of periodontics & restorative dentistry.

[42]  Henry W K Luk,et al.  Precision surgical template for implant placement: a new systematic approach. , 2002, Clinical implant dentistry and related research.

[43]  Jean Loup Coudert,et al.  Reliability of preoperative planning of an image-guided system for oral implant placement based on 3-dimensional images: an in vivo study. , 2003, The International journal of oral & maxillofacial implants.

[44]  C Runte,et al.  Evaluation of accuracy of insertion of dental implants and prosthetic treatment by computer-aided navigation in minipigs. , 2003, The British journal of oral & maxillofacial surgery.

[45]  W Freysinger,et al.  Head and neck tumors: fractionated frameless stereotactic interstitial brachytherapy-initial experience. , 2000, Radiology.

[46]  V. Seifert,et al.  Laser Surface Scanning for Patient Registration in Intracranial Image-guided Surgery , 2002, Neurosurgery.

[47]  C Politis,et al.  Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study. , 2003, International journal of oral and maxillofacial surgery.

[48]  E D Adrian,et al.  Trajectory surgical guide stent for implant placement. , 1992, The Journal of prosthetic dentistry.

[49]  H Bergmann,et al.  Positioning of dental implants using computer-aided navigation and an optical tracking system: case report and presentation of a new method. , 1999, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[50]  O Odlum A method of eliminating streak artifacts from metallic dental restorations in CTs of head and neck cancer patients. , 2001, Special care in dentistry : official publication of the American Association of Hospital Dentists, the Academy of Dentistry for the Handicapped, and the American Society for Geriatric Dentistry.

[51]  R. Ewers,et al.  Basic research and 12 years of clinical experience in computer-assisted navigation technology: a review. , 2005, International journal of oral and maxillofacial surgery.

[52]  C H Basten,et al.  The use of radiopaque templates for predictable implant placement. , 1995, Quintessence international.

[53]  F. M. Gardner,et al.  Fabrication of a guide for radiographic evaluation and surgical placement of implants. , 1995, The Journal of prosthetic dentistry.

[54]  Predrag Sukovic,et al.  Accuracy of implant placement with a stereolithographic surgical guide. , 2003, The International journal of oral & maxillofacial implants.

[55]  M. Jeffcoat,et al.  A comparison of the diagnostic advantages of panoramic radiography and computed tomography scanning for placement of root form dental implants. , 1994, Clinical oral implants research.

[56]  Basten Ch,et al.  The use of radiopaque templates for predictable implant placement. , 1995 .

[57]  Matthias Schneider,et al.  Frameless intraoperative navigation and referencing in maxillofacial surgery - advances and limitations , 2001, CARS.

[58]  Robert J. Maciunas,et al.  Registration of head CT images to physical space using a weighted combination of points and surfaces [image-guided surgery] , 1998, IEEE Transactions on Medical Imaging.

[59]  Wolfgang Birkfellner,et al.  A head-mounted operating binocular for augmented reality visualization in medicine - design and initial evaluation , 2002, IEEE Transactions on Medical Imaging.

[60]  Guillaume Champleboux,et al.  Precision of transfer of preoperative planning for oral implants based on cone-beam CT-scan images through a robotic drilling machine. , 2002, Clinical oral implants research.

[61]  Jay B. West,et al.  Predicting error in point-based registration , 2001 .

[62]  M Naitoh,et al.  Can implants be correctly angulated based on surgical templates used for osseointegrated dental implants? , 2000, Clinical oral implants research.

[63]  C E Besimo,et al.  Accuracy of implant treatment planning utilizing template-guided reformatted computed tomography. , 2000, Dento maxillo facial radiology.

[64]  J E Zöller,et al.  Use of an image-guided navigation system in dental implant surgery in anatomically complex operation sites. , 2001, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[65]  R Jacobs,et al.  Predictability of a three-dimensional planning system for oral implant surgery. , 1999, Dento maxillo facial radiology.

[66]  T W Chow,et al.  The Use of Lipiodol in Spiral Tomography for Dental Implant Imaging , 2003, Implant dentistry.

[67]  Michael W. Vannier,et al.  Three-dimensional dental imaging by spiral CT , 1995, Medical Imaging.

[68]  Klaus-Peter Hermann,et al.  Dental-CT: Bildqualität und Strahlenexposition in Abhängigkeit von den Scanparametern , 2008 .

[69]  D A Garber,et al.  The esthetic dental implant: letting restoration be the guide. , 1995, The Journal of oral implantology.

[70]  O. Jensen,et al.  Anterior maxillary alveolar distraction osteogenesis: a prospective 5-year clinical study. , 2002, The International journal of oral & maxillofacial implants.

[71]  H Bergmann,et al.  In-vitro assessment of a registration protocol for image guided implant dentistry. , 2001, Clinical oral implants research.

[72]  Scott D. Ganz Computer-Guided Surgery Utilizing a Computer-Milled Surgical Template , 2001 .

[73]  M. Çehreli,et al.  Fabrication of a dual-purpose surgical template for correct labiopalatal positioning of dental implants. , 2000, The International journal of oral & maxillofacial implants.

[74]  R W Toothaker,et al.  Using lead foil as a radiopaque marker for computerized tomography imaging when implant treatment planning. , 1997, The Journal of prosthetic dentistry.

[75]  Franz Kainberger,et al.  Evaluation of accuracy of computer-aided intraoperative positioning of endosseous oral implants in the edentulous mandible. , 2002, Clinical oral implants research.