Kidney targeting and puncturing during percutaneous nephrolithotomy: recent advances and future perspectives.

BACKGROUND AND PURPOSE Precise needle puncture of the kidney is a challenging and essential step for successful percutaneous nephrolithotomy (PCNL). Many devices and surgical techniques have been developed to easily achieve suitable renal access. This article presents a critical review to address the methodologies and techniques for conducting kidney targeting and the puncture step during PCNL. Based on this study, research paths are also provided for PCNL procedure improvement. METHODS Most relevant works concerning PCNL puncture were identified by a search of Medline/PubMed, ISI Web of Science, and Scopus databases from 2007 to December 2012. Two authors independently reviewed the studies. RESULTS A total of 911 abstracts and 346 full-text articles were assessed and discussed; 52 were included in this review as a summary of the main contributions to kidney targeting and puncturing. CONCLUSIONS Multiple paths and technologic advances have been proposed in the field of urology and minimally invasive surgery to improve PCNL puncture. The most relevant contributions, however, have been provided by the application of medical imaging guidance, new surgical tools, motion tracking systems, robotics, and image processing and computer graphics. Despite the multiple research paths for PCNL puncture guidance, no widely acceptable solution has yet been reached, and it remains an active and challenging research field. Future developments should focus on real-time methods, robust and accurate algorithms, and radiation free imaging techniques.

[1]  Ken Chen,et al.  Augmenting intraoperative ultrasound with preoperative magnetic resonance planning models for percutaneous renal access , 2012, BioMedical Engineering OnLine.

[2]  Christina Kalogeropoulou,et al.  Imaging in percutaneous nephrolithotomy. , 2009, Journal of endourology.

[3]  Shashikant Mishra,et al.  Training in percutaneous nephrolithotomy , 2013, Current opinion in urology.

[4]  Ziv Yaniv,et al.  Electromagnetic tracking in the clinical environment. , 2009, Medical physics.

[5]  Septimiu E. Salcudean,et al.  Needle steering and motion planning in soft tissues , 2005, IEEE Transactions on Biomedical Engineering.

[6]  R. Scarpa,et al.  New developments in percutaneous techniques for simple and complex branched renal stones , 2011, Current opinion in urology.

[7]  S. Guven,et al.  Successful percutaneous nephrolithotomy in children: multicenter study on current status of its use, efficacy and complications using Clavien classification. , 2011, The Journal of urology.

[8]  Shashikant Mishra,et al.  Single-step percutaneous nephrolithotomy (microperc): the initial clinical report. , 2011, The Journal of urology.

[9]  Uday Patel,et al.  Computed tomography for percutaneous renal access. , 2009, Journal of endourology.

[10]  F. Coe,et al.  Clinical practice. Calcium kidney stones. , 2010, The New England journal of medicine.

[11]  Osamu Ukimura,et al.  Image-guided surgery in minimally invasive urology , 2010, Current opinion in urology.

[12]  B. Song,et al.  Stereotactic localisation system: a modified puncture technique for percutaneous nephrolithotomy , 2012, Urological Research.

[13]  Mahesh Desai,et al.  The Clinical Research Office of the Endourological Society Percutaneous Nephrolithotomy Global Study: indications, complications, and outcomes in 5803 patients. , 2011, Journal of endourology.

[14]  Ali Serdar Gözen,et al.  Augmented reality: a new tool to improve surgical accuracy during laparoscopic partial nephrectomy? Preliminary in vitro and in vivo results. , 2009, European urology.

[15]  Yohan Payan,et al.  Rigid Registration of Freehand 3D Ultrasound and CT-Scan Kidney Images , 2004, MICCAI.

[16]  Noor Buchholz,et al.  Extracorporeal shockwave lithotripsy vs. percutaneous nephrolithotomy vs. flexible ureterorenoscopy for lower-pole stones , 2012, Arab journal of urology.

[17]  R. Autorino,et al.  Modified supine versus prone position in percutaneous nephrolithotomy for renal stones treatable with a single percutaneous access: a prospective randomized trial. , 2008, European urology.

[18]  Y Payan,et al.  Computer‐assisted access to the kidney , 2005, The international journal of medical robotics + computer assisted surgery : MRCAS.

[19]  R. Autorino,et al.  Prone or supine: is this the question? , 2008, European urology.

[20]  John Lazarus,et al.  The Locator: novel percutaneous nephrolithotomy apparatus to aid collecting system puncture--a preliminary report. , 2011, Journal of endourology.

[21]  Bostjan Likar,et al.  A review of 3D/2D registration methods for image-guided interventions , 2012, Medical Image Anal..

[22]  R. Dasgupta,et al.  Percutaneous nephrolithotomy: does position matter? – prone, supine and variations , 2013, Current opinion in urology.

[23]  M. Bader,et al.  The "all-seeing needle": initial results of an optical puncture system confirming access in percutaneous nephrolithotomy. , 2011, European urology.

[24]  T. Knoll,et al.  Percutaneous nephrolithotomy under combined sonographic/radiologic guided puncture: results of a learning curve using the modified Clavien grading system , 2013, World Journal of Urology.

[25]  Dan Stoianovici,et al.  Urologic robots and future directions , 2009, Current opinion in urology.

[26]  Mathew D. Sorensen,et al.  Renal calyceal anatomy characterization with 3-dimensional in vivo computerized tomography imaging. , 2013, The Journal of urology.

[27]  H. Meinzer,et al.  iPad-assisted percutaneous access to the kidney using marker-based navigation: initial clinical experience. , 2012, European urology.

[28]  J. Marescaux,et al.  Augmented reality in laparoscopic surgical oncology. , 2011, Surgical oncology.

[29]  Mathew D. Sorensen,et al.  B-mode ultrasound versus color Doppler twinkling artifact in detecting kidney stones. , 2013, Journal of endourology.

[30]  G. Preminger,et al.  Beyond prone position in percutaneous nephrolithotomy: a comprehensive review. , 2008, European urology.

[31]  O. Ozkaya,et al.  Modified Clavien classification in percutaneous nephrolithotomy: assessment of complications in children. , 2010, The Journal of urology.

[32]  Nassir Navab,et al.  Automatic CT-ultrasound registration for diagnostic imaging and image-guided intervention , 2008, Medical Image Anal..

[33]  K. Cleary,et al.  Image-guided interventions: technology review and clinical applications. , 2010, Annual review of biomedical engineering.

[34]  Maurice Stephan Michel,et al.  Complications in percutaneous nephrolithotomy. , 2007, European urology.

[35]  G. Chiang,et al.  Ureteroscopy in pediatric patients with spinal abnormalities. , 2013, Journal of endourology.

[36]  A. Ray,et al.  Comparison of supracostal versus infracostal percutaneous nephrolithotomy using the novel prone-flexed patient position. , 2011, Journal of endourology.

[37]  Jocelyne Troccaz,et al.  POD-02.08: Aid to percutaneous renal access by virtual projection of the ultrasound puncture tract onto fluoroscopic images , 2007 .

[38]  Hans-Peter Meinzer,et al.  Navigated renal access using electromagnetic tracking: an initial experience , 2010, Surgical Endoscopy.

[39]  P. Cinquin Erratum to « How today's robots work and perspectives for the future » [JVS 148 (5S) (2011), e12–e18] , 2012 .

[40]  Pierre Conort,et al.  Training in percutaneous nephrolithotomy--a critical review. , 2008, European urology.

[41]  R. Mohammadi,et al.  A study on comparative outcomes of percutaneous nephrolithotomy in prone, supine, and flank positions , 2013, World Journal of Urology.

[42]  Arvind Ganpule,et al.  Robotic flexible ureteroscopy for renal calculi: initial clinical experience. , 2011, The Journal of urology.

[43]  P. Cinquin How today's robots work and perspectives for the future. , 2011, Journal of visceral surgery.

[44]  Michael N. Ferrandino,et al.  Factors affecting patient radiation exposure during percutaneous nephrolithotomy. , 2010, The Journal of urology.

[45]  N. Burgess,et al.  Percutaneous nephrolithotomy in the United kingdom: results of a prospective data registry. , 2012, European urology.

[46]  Russell H. Taylor,et al.  Augmented reality during robot-assisted laparoscopic partial nephrectomy: toward real-time 3D-CT to stereoscopic video registration. , 2009, Urology.

[47]  Jenny Dankelman,et al.  Needle-tissue interaction forces--a survey of experimental data. , 2012, Medical engineering & physics.

[48]  Jaydev P. Desai,et al.  A biplanar fluoroscopic approach for the measurement, modeling, and simulation of needle and soft-tissue interaction , 2007, Medical Image Anal..

[49]  A. Häcker,et al.  Laser-guided percutaneous kidney access with the Uro Dyna-CT: first experience of three-dimensional puncture planning with an ex vivo model , 2013, World Journal of Urology.

[50]  Alin Albu-Schäffer,et al.  The DLR MIRO: a versatile lightweight robot for surgical applications , 2008, Ind. Robot.

[51]  Martin Hoheisel,et al.  Electromagnetic field-based navigation for percutaneous punctures on C-arm CT: experimental evaluation and clinical application , 2008, European Radiology.

[52]  Wan Sing Ng,et al.  `Smart' Needle for Percutaneous Surgery: Influential Factor Investigation , 2007, 2007 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.