Simultaneous measurement of temperature and refractive index based on a hybrid surface plasmon resonance multimode interference fiber sensor.

We propose and demonstrate a hybrid fiber-based sensor combining a multimode interference (MMI) structure and a surface plasmon resonance (SPR) structure for simultaneous measurement of temperature and refractive index (RI) of a liquid sample. We configure the MMI structure by connecting a single-mode fiber, a no-core fiber, and a single-mode fiber sequentially. We set up the SPR structure by coating a gold film with a thickness of 50 nm on the surface of the no-core fiber. We measure the sensitivity of RI and the temperature of the MMI and SPR structure, respectively. Then we obtain the coefficient matrix to simultaneously measure the temperature and RI of a liquid sample and obtain the highest RI sensitivity of 2061.6 nm/RIU and temperature sensitivity of 37.9 pm/°C. We verify the feasibility of the sensor in liquid alcohol. The testing results indicate that the proposed sensor and testing method are feasible, accurate, and convenient.

[1]  Kwan Seob Park,et al.  Cross-talk free and ultra-compact fiber optic sensor for simultaneous measurement of temperature and refractive index. , 2010, Optics express.

[2]  M.S. Demokan,et al.  Simultaneous temperature and refractive index measurements using a 3/spl deg/ slanted multimode fiber Bragg grating , 2006, Journal of Lightwave Technology.

[3]  Y. Matsui,et al.  Effects of gold film thickness on spectrum profile and sensitivity of a multimode-optical-fiber SPR sensor , 2008 .

[4]  Yong Zhao,et al.  High Sensitive Modal Interferometer for Temperature and Refractive Index Measurement , 2015, IEEE Photonics Technology Letters.

[5]  Jinsong Li,et al.  Highly sensitive selectively coated D-shape photonic crystal fibers for surface plasmon resonance sensing , 2019, Physics Letters A.

[6]  Yu Zhang,et al.  Twin-core fiber SPR sensor. , 2015, Optics letters.

[7]  Anbo Wang,et al.  Simultaneous measurement of refractive index and temperature based on a reflection-mode long-period grating and an intrinsic Fabry-Perot interferometer sensor. , 2005, Optics letters.

[8]  Hai Xiao,et al.  Temperature Compensated Refractometer Based on a Cascaded SMS/LPFG Fiber Structure , 2014 .

[9]  Yunjiang Rao,et al.  Simultaneous measurement of refractive index and temperature using a single ultralong-period fiber grating , 2005 .

[10]  Jacques Albert,et al.  Intrinsic temperature sensitivity of tilted fiber Bragg grating based surface plasmon resonance sensors. , 2010, Optics express.

[11]  I. Bennion,et al.  Sampled fiber Bragg grating for simultaneous refractive-index and temperature measurement. , 2001, Optics letters.

[12]  Dora Juan Juan Hu,et al.  Long period grating cascaded to photonic crystal fiber modal interferometer for simultaneous measurement of temperature and refractive index. , 2012, Optics letters.

[13]  Zhilin Xu,et al.  Simultaneous measurement of refractive index and temperature using multimode microfiber-based dual Mach-Zehnder interferometer. , 2014, Optics letters.

[14]  Xing Zhang,et al.  Simultaneous measurement of refractive index and temperature based on asymmetric structures modal interference , 2016 .

[15]  Wei Wang,et al.  Single-Mode-Multimode Fiber Structure Based Sensor for Simultaneous Measurement of Refractive Index and Temperature , 2013, IEEE Sensors Journal.

[16]  Lecheng Li,et al.  In-line fiber Mach–Zehnder interferometer for simultaneous measurement of refractive index and temperature based on thinned fiber , 2012 .

[17]  Jing Li,et al.  Matching optimization for SFS-structured interferometers with step-index fibers. , 2018, Optics express.

[18]  Denis Donlagic,et al.  High resolution, all-fiber, micro-machined sensor for simultaneous measurement of refractive index and temperature. , 2014, Optics express.

[19]  A.P. Zhang,et al.  Sandwiched long-period gratings for simultaneous measurement of refractive index and temperature , 2005, IEEE Photonics Technology Letters.

[20]  Ya‐nan Zhang,et al.  High-sensitivity and tunable refractive index sensor based on dual-core photonic crystal fiber , 2016 .

[21]  Marta S. Ferreira,et al.  Determination of thermo-optic coefficient of ethanol-water mixtures with optical fiber tip sensor , 2018, Optical Fiber Technology.

[22]  Simultaneous measurement of refractive index and temperature based on a long period fiber grating inscribed in a photonic crystal fiber with an electric-arc discharge , 2018, Instrumentation Science & Technology.

[23]  Banshi D Gupta,et al.  Influence of temperature on the sensitivity and signal-to-noise ratio of a fiber-optic surface-plasmon resonance sensor. , 2006, Applied optics.

[24]  D. Solimini Loss Measurement of Organic Materials at 6328 Å , 1966 .

[25]  M. Foroutan Liquid−Liquid Equilibria of Aqueous Two-Phase Poly(vinylpyrrolidone) and K2HPO4/KH2PO4 Buffer: Effects of pH and Temperature , 2007 .

[26]  Shuhui Liu,et al.  Liquid Core Fiber Interferometer for Simultaneous Measurement of Refractive Index and Temperature , 2019, IEEE Photonics Technology Letters.

[27]  Yi-Wei Shi,et al.  Hollow fiber surface plasmon resonance sensor for the detection of liquid with high refractive index. , 2013, Optics express.

[28]  K. Sooley,et al.  Tapered fiber Mach–Zehnder interferometer for simultaneous measurement of refractive index and temperature , 2009 .

[29]  Tiegen Liu,et al.  A Hybrid Multimode Interference Structure-Based Refractive Index and Temperature Fiber Sensor , 2016, IEEE Sensors Journal.

[30]  Pedro A. S. Jorge,et al.  Simultaneous measurement of refractive index and temperature using multimode interference inside a high birefringence fiber loop mirror , 2013 .

[31]  Bo Liu,et al.  Fiber modal interferometer with embedded fiber Bragg grating for simultaneous measurements of refractive index and temperature , 2013 .