Evaluation of respiration-correlated digital tomosynthesis in lung.

Digital tomosynthesis (DTS) with a linear accelerator-mounted imaging system provides a means of reconstructing tomographic images from radiographic projections over a limited gantry arc, thus requiring only a few seconds to acquire. Its application in the thorax, however, often results in blurred images from respiration-induced motion. This work evaluates the feasibility of respiration-correlated (RC) DTS for soft-tissue visualization and patient positioning. Image data acquired with a gantry-mounted kilovoltage imaging system while recording respiration were retrospectively analyzed from patients receiving radiotherapy for non-small-cell lung carcinoma. Projection images spanning an approximately 30 degrees gantry arc were sorted into four respiration phase bins prior to DTS reconstruction, which uses a backprojection, followed by a procedure to suppress structures above and below the reconstruction plane of interest. The DTS images were reconstructed in planes at different depths through the patient and normal to a user-selected angle close to the center of the arc. The localization accuracy of RC-DTS was assessed via a comparison with CBCT. Evaluation of RC-DTS in eight tumors shows visible reduction in image blur caused by the respiratory motion. It also allows the visualization of tumor motion extent. The best image quality is achieved at the end-exhalation phase of the respiratory motion. Comparison of RC-DTS with respiration-correlated cone-beam CT in determining tumor position, motion extent and displacement between treatment sessions shows agreement in most cases within 2-3 mm, comparable in magnitude to the intraobserver repeatability of the measurement. These results suggest the method's applicability for soft-tissue image guidance in lung, but must be confirmed with further studies in larger numbers of patients.

[1]  D. Kopans,et al.  Tomographic mammography using a limited number of low-dose cone-beam projection images. , 2003, Medical physics.

[2]  T D Kampp,et al.  The backprojection method applied to classical tomography. , 1986, Medical physics.

[3]  J Duryea,et al.  Digital tomosynthesis of hand joints for arthritis assessment. , 2003, Medical physics.

[4]  C. Ling,et al.  Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging. , 2002, International journal of radiation oncology, biology, physics.

[5]  E. Yorke,et al.  Respiratory gating for liver tumors: Use in dose escalation , 2003 .

[6]  Fang-Fang Yin,et al.  On-board patient positioning for head-and-neck IMRT: comparing digital tomosynthesis to kilovoltage radiography and cone-beam computed tomography. , 2007, International journal of radiation oncology, biology, physics.

[7]  Baojun Li,et al.  Optimization of slice sensitivity profile for radiographic tomosynthesis. , 2007, Medical physics.

[8]  J A Rowlands,et al.  Megavoltage cone beam digital tomosynthesis (MV-CBDT) for image-guided radiotherapy: a clinical investigational system , 2008, Physics in medicine and biology.

[9]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .

[10]  C C Ling,et al.  Developments in megavoltage cone beam CT with an amorphous silicon EPID: reduction of exposure and synchronization with respiratory gating. , 2005, Medical physics.

[11]  Imad Ali,et al.  Comparison of kilovoltage cone-beam computed tomography with megavoltage projection pairs for paraspinal radiosurgery patient alignment and position verification. , 2008, International journal of radiation oncology, biology, physics.

[12]  M. V. van Herk,et al.  Respiratory correlated cone beam CT. , 2005, Medical physics.

[13]  M. Oldham,et al.  Digital tomosynthesis with an on-board kilovoltage imaging device. , 2006, International journal of radiation oncology, biology, physics.

[14]  Ellen Yorke,et al.  Integrating respiratory gating into a megavoltage cone-beam CT system. , 2006, Medical Physics (Lancaster).

[15]  N Pallikarakis,et al.  A wavelet-based method for removal of out-of-plane structures in digital tomosynthesis. , 1998, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[16]  N Pallikarakis,et al.  Three-dimensional localisation based on projectional and tomographic image correlation: an application for digital tomosynthesis. , 1999, Medical engineering & physics.

[17]  Timothy D. Solberg,et al.  Phase versus amplitude sorting of 4D‐CT data , 2006, Journal of applied clinical medical physics.

[18]  Agung Hertanto,et al.  Observation of interfractional variations in lung tumor position using respiratory gated and ungated megavoltage cone-beam computed tomography. , 2007, International journal of radiation oncology, biology, physics.

[19]  David A. Jaffray,et al.  Respiration correlated cone-beam computed tomography and 4DCT for evaluating target motion in Stereotactic Lung Radiation Therapy , 2006, Acta oncologica.

[20]  T D Kampp,et al.  Digitized longitudinal tomography. , 1981, Investigative radiology.

[21]  Fang-Fang Yin,et al.  On-board four-dimensional digital tomosynthesis: first experimental results. , 2008, Medical physics.

[22]  R. C. Murry,et al.  Digital tomosynthesis: technique modifications and clinical applications for neurovascular anatomy. , 1984, Radiology.

[23]  R L Webber,et al.  An optimal synthetic aperture for circular tomosynthesis. , 1989, Medical physics.

[24]  D. Kopans,et al.  Digital tomosynthesis in breast imaging. , 1997, Radiology.

[25]  Matthias Guckenberger,et al.  Cone-beam CT based image-guidance for extracranial stereotactic radiotherapy of intrapulmonary tumors , 2006, Acta oncologica.

[26]  R A Kruger,et al.  Selective plane removal in limited angle tomographic imaging. , 1985, Medical physics.

[27]  Geoffrey D Hugo,et al.  On-line target position localization in the presence of respiration: a comparison of two methods. , 2007, International journal of radiation oncology, biology, physics.

[28]  Hui Yan,et al.  Evaluation of three types of reference image data for external beam radiotherapy target localization using digital tomosynthesis (DTS). , 2007, Medical physics.

[29]  Nicole M Wink,et al.  Respiratory correlated cone-beam computed tomography on an isocentric C-arm , 2005, Physics in medicine and biology.

[30]  Hui Yan,et al.  Automatic registration between reference and on-board digital tomosynthesis images for positioning verification. , 2008, Medical physics.

[31]  C. Badea,et al.  Image quality in extended ARC filtered digital tomosynthesis , 2001 .

[32]  L. Xing,et al.  Optimizing 4D cone-beam CT acquisition protocol for external beam radiotherapy. , 2007, International journal of radiation oncology, biology, physics.

[33]  Tao Wu,et al.  A comparison of reconstruction algorithms for breast tomosynthesis. , 2004, Medical physics.

[34]  D. G. Grant Tomosynthesis: a three-dimensional radiographic imaging technique. , 1972, IEEE transactions on bio-medical engineering.

[35]  J Pouliot,et al.  Characteristics of megavoltage cone-beam digital tomosynthesis. , 2008, Medical physics.

[36]  G J Kutcher,et al.  Measurement of patient positioning errors in three-dimensional conformal radiotherapy of the prostate. , 1997, International journal of radiation oncology, biology, physics.

[37]  N. Pallikarakis,et al.  Volume Imaging in Fluoroscopy , 1996, Acta radiologica.

[38]  G Panayiotakis,et al.  A method for selective removal of out-of-plane structures in digital tomosynthesis. , 1993, Medical physics.

[39]  Uwe Oelfke,et al.  Linac-integrated 4D cone beam CT: first experimental results , 2006, Physics in medicine and biology.

[40]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[41]  C. Beaulieu,et al.  Circular tomosynthesis: potential in imaging of breast and upper cervical spine--preliminary phantom and in vitro study. , 2003, Radiology.

[42]  Huabei Jiang,et al.  A practical method for three-dimensional reconstruction of joints using a C-arm system and shift-and-add algorithm. , 2005, Medical physics.