Bone orientation and position estimation errors using Cosserat point elements and least squares methods: Application to gait.

The aim of this study was to analyze the accuracy of bone pose estimation based on sub-clusters of three skin-markers characterized by triangular Cosserat point elements (TCPEs) and to evaluate the capability of four instantaneous physical parameters, which can be measured non-invasively in vivo, to identify the most accurate TCPEs. Moreover, TCPE pose estimations were compared with the estimations of two least squares minimization methods applied to the cluster of all markers, using rigid body (RBLS) and homogeneous deformation (HDLS) assumptions. Analysis was performed on previously collected in vivo treadmill gait data composed of simultaneous measurements of the gold-standard bone pose by bi-plane fluoroscopy tracking the subjects' knee prosthesis and a stereophotogrammetric system tracking skin-markers affected by soft tissue artifact. Femur orientation and position errors estimated from skin-marker clusters were computed for 18 subjects using clusters of up to 35 markers. Results based on gold-standard data revealed that instantaneous subsets of TCPEs exist which estimate the femur pose with reasonable accuracy (median root mean square error during stance/swing: 1.4/2.8deg for orientation, 1.5/4.2mm for position). A non-invasive and instantaneous criteria to select accurate TCPEs for pose estimation (4.8/7.3deg, 5.8/12.3mm), was compared with RBLS (4.3/6.6deg, 6.9/16.6mm) and HDLS (4.6/7.6deg, 6.7/12.5mm). Accounting for homogeneous deformation, using HDLS or selected TCPEs, yielded more accurate position estimations than RBLS method, which, conversely, yielded more accurate orientation estimations. Further investigation is required to devise effective criteria for cluster selection that could represent a significant improvement in bone pose estimation accuracy.

[1]  Aurelio Cappozzo,et al.  Non-invasive assessment of superficial soft tissue local displacements during movement: a feasibility study. , 2009, Journal of biomechanics.

[2]  Kevin Ball,et al.  Modeling of the pliant surfaces of the thigh and leg during gait , 1998, Photonics West - Biomedical Optics.

[3]  Aurelio Cappozzo,et al.  Hip joint centre location: an ex vivo study. , 2009, Journal of biomechanics.

[4]  Rita Stagni,et al.  Can cluster deformation be an indicator of soft tissue artefact , 2009 .

[5]  M Damsgaard,et al.  Surface marker cluster translation, rotation, scaling and deformation: Their contribution to soft tissue artefact and impact on knee joint kinematics. , 2015, Journal of biomechanics.

[6]  R Dumas,et al.  A model of the soft tissue artefact rigid component. , 2015, Journal of biomechanics.

[7]  Aurelio Cappozzo,et al.  Reconstruction of skeletal movement using skin markers: comparative assessment of bone pose estimators , 2006, Journal of NeuroEngineering and Rehabilitation.

[8]  A Cappello,et al.  Optimization and smoothing techniques in movement analysis. , 1996, International journal of bio-medical computing.

[9]  William R Taylor,et al.  The weighted optimal common shape technique improves identification of the hip joint center of rotation in vivo , 2011, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[10]  R Dumas,et al.  Soft tissue artifact compensation by linear 3D interpolation and approximation methods. , 2009, Journal of biomechanics.

[11]  C. Spoor,et al.  Rigid body motion calculated from spatial co-ordinates of markers. , 1980, Journal of biomechanics.

[12]  J. Challis A procedure for determining rigid body transformation parameters. , 1995, Journal of biomechanics.

[13]  Aurelio Cappozzo,et al.  A soft tissue artefact model driven by proximal and distal joint kinematics. , 2014, Journal of biomechanics.

[14]  Kamiar Aminian,et al.  Soft tissue artifact distribution on lower limbs during treadmill gait: Influence of skin markers' location on cluster design. , 2015, Journal of biomechanics.

[15]  Aurelio Cappozzo,et al.  A hip joint kinematics driven model for the generation of realistic thigh soft tissue artefacts. , 2013, Journal of biomechanics.

[16]  Dan K Ramsey,et al.  Effect of skin movement artifact on knee kinematics during gait and cutting motions measured in vivo. , 2005, Gait & posture.

[17]  F. Veldpaus,et al.  A least-squares algorithm for the equiform transformation from spatial marker co-ordinates. , 1988, Journal of biomechanics.

[18]  K. Mardia,et al.  Statistical Shape Analysis , 1998 .

[19]  M. Rubin,et al.  Unphysical properties of the rotation tensor estimated by least squares optimization with specific application to biomechanics , 2016 .

[20]  Alon Wolf,et al.  Soft Tissue Artifact compensation using Triangular Cosserat Point Elements (TCPEs) , 2014 .

[21]  I Söderkvist,et al.  Determining the movements of the skeleton using well-configured markers. , 1993, Journal of biomechanics.

[22]  Anthony G Schache,et al.  Non-invasive assessment of soft-tissue artifact and its effect on knee joint kinematics during functional activity. , 2010, Journal of biomechanics.

[23]  Alon Wolf,et al.  Bone Pose Estimation in the Presence of Soft Tissue Artifact Using Triangular Cosserat Point Elements , 2015, Annals of Biomedical Engineering.

[24]  Marcus G Pandy,et al.  Standardization proposal of soft tissue artefact description for data sharing in human motion measurements. , 2017, Journal of biomechanics.

[25]  Aurelio Cappozzo,et al.  What portion of the soft tissue artefact requires compensation when estimating joint kinematics? , 2015, Journal of biomechanical engineering.

[26]  Aurelio Cappozzo,et al.  Metrics for Describing Soft-Tissue Artefact and Its Effect on Pose, Size, and Shape of Marker Clusters , 2014, IEEE Transactions on Biomedical Engineering.

[27]  R Dumas,et al.  Rigid and non-rigid geometrical transformations of a marker-cluster and their impact on bone-pose estimation. , 2015, Journal of biomechanics.

[28]  B. Nigg,et al.  Tibiofemoral and tibiocalcaneal motion during walking: external vs. skeletal markers , 1997 .

[29]  Jean-Philippe Thiran,et al.  Soft Tissue Artifact Assessment During Treadmill Walking in Subjects With Total Knee Arthroplasty , 2013, IEEE Transactions on Biomedical Engineering.

[30]  Michael Damsgaard,et al.  Do kinematic models reduce the effects of soft tissue artefacts in skin marker-based motion analysis? An in vivo study of knee kinematics. , 2010, Journal of biomechanics.

[31]  Michael Damsgaard,et al.  A linear soft tissue artefact model for human movement analysis: proof of concept using in vivo data. , 2012, Gait & posture.

[32]  B. Galna,et al.  Quantification of soft tissue artifact in lower limb human motion analysis: a systematic review. , 2010, Gait & posture.

[33]  A. Cappozzo,et al.  Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation. , 2005, Gait & posture.

[34]  U.D. Croce,et al.  Surface-marker cluster design criteria for 3-D bone movement reconstruction , 1997, IEEE Transactions on Biomedical Engineering.