Risk Factors for Persistent Carriage of MRSA

The main advantage of this apparatus is the treatment of contaminated materials inside hospital wards, at the point of initial collection, by nonspecialized staff. As it works without grinding, no potentially infectious particles are suspended in the air during the treatment The pancakes produced are solid and easy to manipulate. After treatment, waste can be eliminated as household rubbish in classic incinerators. The cost of this final treatment is much lower than the cost of incineration of infectious waste. Finally, this apparatus is both a waste disinfection and disposal system that avoids hazardous transport from the point of initial collection to the incinerator. Nevertheless, it is necessary to promote separation between contaminated and nonhazardous hospital waste that requires no special handling and disposal. It would be helpful to implement a program for reducing biomedical waste, including reviewing waste practices, educating staff, and redefining infectious waste (the small proportion of medical waste that could potentially transmit an infectious disease).

[1]  R. Pleus,et al.  Health Effects from Hazardous Waste Incineration Facilities: Five Case Studies 1 , 1996, Toxicology and industrial health.

[2]  J I Blenkharn,et al.  The disposal of clinical wastes. , 1995, The Journal of hospital infection.

[3]  V. Bencko,et al.  Hospital waste management practice in the Czech Republic. , 1993, Central European journal of public health.

[4]  C. Collins,et al.  The microbiological hazards of municipal and clinical wastes. , 1992, The Journal of applied bacteriology.

[5]  H. Fujikawa,et al.  Kinetics of Escherichia coli destruction by microwave irradiation , 1992, Applied and environmental microbiology.

[6]  A Z Dragas,et al.  The killing activity of microwaves on some non-sporogenic and sporogenic medically important bacterial strains. , 1991, The Journal of hospital infection.

[7]  J. Keene Medical waste: a minimal hazard. , 1991, Infection control and hospital epidemiology.

[8]  G. Liss,et al.  Improper office disposal of needles and other sharps: an occupational hazard outside of health care institutions. , 1990, Canadian journal of public health = Revue canadienne de sante publique.

[9]  G. Scott,et al.  Emission of viable bacteria in the exhaust flue from a waste incinerator. , 1990, The Journal of hospital infection.

[10]  J I Blenkharn,et al.  Emission of viable bacteria in the exhaust flue gases from a hospital incinerator. , 1989, The Journal of hospital infection.

[11]  D. K. Jeng,et al.  Mechanism of microwave sterilization in the dry state , 1987, Applied and environmental microbiology.

[12]  G R Vela,et al.  Mechanism of lethal action of 2,450-MHz radiation on microorganisms , 1979, Applied and environmental microbiology.

[13]  S A Goldblith,et al.  Effect of Microwaves on Escherichia coli and Bacillus subtilis. , 1967, Applied microbiology.

[14]  G. Phillips,et al.  Microbiological aspects of clinical waste. , 1999, The Journal of hospital infection.

[15]  M. Escaf,et al.  A program for reducing biomedical waste: the Wellesley Hospital experience. , 1996, The Canadian journal of infection control : the official journal of the Community & Hospital Infection Control Association-Canada = Revue canadienne de prevention des infections.