Multisite Pooling Study Using Ligase Chain Reaction in Screening for Genital Chlamydia trachomatis Infections

Background Ligase chain reaction (LCR), a nucleic acid amplification assay, is a highly specific and sensitive test for detecting Chlamydia trachomatis in cervical and urethral swabs as well as first-void urine specimens. Goal To examine the suitability of using the LCR test to detect C trachomatis in pooled cervical specimens. Study Design The performance of LCR in pooled specimens was compared with individual specimen testing at six laboratories using 3,170 cervical swab specimens randomly selected from specimens received for routine testing in the participating laboratories. These samples then were combined consecutively into 634 pools of 5 specimens and 317 pools of 10 specimens. A reduced sample to cutoff ratio of 0.2 or more was used for the pooled specimens. Results Of the 188 positive specimens (98.9%), 186 were identified when single specimens were analyzed. When pools of 5 or 10 specimens were evaluated, 99.5% and 98.9% of the positive swabs, respectively, were identified correctly. Two positive specimens were detected only through pooling. Conclusions Pooling samples for detection of C trachomatis by LCR is sensitive and specific. Depending on the prevalence of infection (positivity), LCR testing may result in cost savings, as compared with individual testing of specimens.

[1]  A. Sproston,et al.  Pooling Cervical Swabs and Testing by Ligase Chain Reaction Are Accurate and Cost-Saving Strategies for Diagnosis ofChlamydia trachomatis , 2000, Journal of Clinical Microbiology.

[2]  A. Sproston,et al.  The impact on accuracy and cost of ligase chain reaction testing by pooling urine specimens for the diagnosis of Chlamydia trachomatis infections. , 1999, Sexually transmitted diseases.

[3]  T. Quinn,et al.  Evaluation of the Digene Hybrid Capture II CT-ID Test for Detection of Chlamydia trachomatis in Endocervical Specimens , 1999, Journal of Clinical Microbiology.

[4]  Helen H. Lee,et al.  Performance of Transcription-Mediated Amplification and Ligase Chain Reaction Assays for Detection of Chlamydial Infection in Urogenital Samples Obtained by Invasive and Noninvasive Methods , 1998, Journal of Clinical Microbiology.

[5]  M. R. Howell,et al.  Use of Ligase Chain Reaction with Urine versus Cervical Culture for Detection of Chlamydia trachomatis in an Asymptomatic Military Population of Pregnant and Nonpregnant Females Attending Papanicolaou Smear Clinics , 1998, Journal of Clinical Microbiology.

[6]  R. Peeling,et al.  Pooling of urine specimens for PCR testing: a cost saving strategy for Chlamydia trachomatis control programmes. , 1998, Sexually transmitted infections.

[7]  M. R. Howell,et al.  Pooling Urine Samples for Ligase Chain Reaction Screening for Genital Chlamydia trachomatis Infection in Asymptomatic Women , 1998, Journal of Clinical Microbiology.

[8]  C. Black,et al.  Current methods of laboratory diagnosis of Chlamydia trachomatis infections. , 1998, Clinical microbiology reviews.

[9]  Helen H. Lee,et al.  Diagnosis of Chlamydia trachomatis genitourinary infection in women by ligase chain reaction assay of urine , 1995, The Lancet.