A fast rotating scanning unit for real-time three-dimensional echo data acquisition.

Most three-dimensional (3-D) echocardiography (3-DE) systems today are based on off-line methods where a large number of cross-sectional 2-D scans have to be acquired sequentially before a 3-D image can be reconstructed. Because acquisition is done step-by-step based on ECG triggering plus respiratory gating, this introduces motion artefacts and takes significant acquisition time. Another 3-D approach is based on 2-D transducers and parallel beam-forming. Such a system is very complex. In this manuscript, a fast continuously-rotating scanning unit, based on a 64-element phased-array transducer, is described. Typical rotation speed of the 3-D unit is 8 rotations per s. Therefore, 16 3-D volume datasets can be acquired per s in real-time. The first clinical examples as acquired with this probe are presented.

[1]  G. Marx,et al.  Dynamic Three‐Dimensional Echocardiography: , 1994 .

[2]  R. E. Davidsen,et al.  Two-Dimensional Random Arrays for Real Time Volumetric Imaging , 1994 .

[3]  F J Ten Cate,et al.  Paraplane analysis from precordial three-dimensional echocardiographic data sets for rapid and accurate quantification of left ventricular volume and function: a comparison with magnetic resonance imaging. , 1999, American heart journal.

[4]  J. Roelandt,et al.  Ultrasonic dynamic three-dimensional visualization of the heart with a multiplane transesophageal imaging transducer. , 1994, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[5]  S Rocchi,et al.  Nearly real-time visualization of arbitrary two-dimensional sections from three-dimensional acquisition. , 1996, Ultrasound in medicine & biology.

[6]  Stephen W. Smith,et al.  Update on 2-D array transducers for medical ultrasound , 1995, 1995 IEEE Ultrasonics Symposium. Proceedings. An International Symposium.

[7]  Yoshiro Tomikawa,et al.  Ultrasonic motors—constructions/characteristics/applications , 1989 .

[8]  James F. Greenleaf,et al.  Multidimensional Cardiac Imaging , 1993 .

[9]  A Salustri,et al.  Ultrasonic three-dimensional reconstruction of the heart. , 1995, Ultrasound in medicine & biology.

[10]  A Salustri,et al.  Three-dimensional echocardiography of the thoracic aorta. , 1996, European heart journal.

[11]  S.W. Smith,et al.  Two-dimensional arrays for medical ultrasound , 1991, IEEE 1991 Ultrasonics Symposium,.

[12]  J. Wallaschek Piezoelectric Ultrasonic Motors , 1995 .

[13]  R Erbel,et al.  Tomographic three-dimensional echocardiographic determination of chamber size and systolic function in patients with left ventricular aneurysm: comparison to magnetic resonance imaging, cineventriculography, and two-dimensional echocardiography. , 1997, Circulation.

[14]  T. Abraham,et al.  Three-dimensional surface area of the aortic valve orifice by three-dimensional echocardiography: clinical validation of a novel index for assessment of aortic stenosis. , 1998, American heart journal.

[15]  Joseph Kisslo,et al.  Pseudoaneurysm of the Left Ventricle , 1986 .