Healing response to the clamshell device for closure of intracardiac defects in humans

The healing response to intracardiac devices in humans is largely unknown. During regulatory trials using the Clamshell device in over 800 patients, attempts were made to perform histopathological evaluation of all explanted devices. We reviewed all those with complete histopathological examination (n = 12) from Fontan baffles (n = 4), ventricular septal defects (n = 2), and atrial septal defects (ASD; n = 6), explanted at 2.7 months to 3.6 years (median, 1.6 years), at autopsy (n = 1) or surgery (n = 11), performed for residual defects (n = 5), atrial masses (n = 3), or Fontan revision (n = 3). All but one were nearly (n = 3) or completely (n = 8) covered by pseudointima, composed of fibroelastic tissue, predominantly collagen, with focal foreign body reaction in contact with fabric, without acute inflammation or infection. Atrial masses of granulation tissue were present in three cases (ASD), opposite to protruding fractured arms. No associations were identified between coverage and closure status, position, arm fractures, or implant period. In conclusion, the healing response to transcatheter Clamshell implantation in humans is characterized by a relatively rapid development of a nonthrombotic pseudointima composed of fibroelastic tissue with minimal foreign body reaction. Cathet Cardiovasc Intervent 2001;54:101–111. © 2001 Wiley‐Liss, Inc.

[1]  John A. Wright,et al.  Acute animal studies of the STARFlex system: A new self‐centering cardioSEAL septal occluder , 2000, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[2]  Y. Han,et al.  New self‐expanding patent foramen ovale occlusion device , 1999, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[3]  K. Amplatz,et al.  Transvenous closure of secundum atrial septal defects: preliminary results with a new self-expanding nitinol prosthesis in a swine model. , 1997, Circulation.

[4]  J. Cheatham,et al.  Intermediate-term outcome of transcatheter secundum atrial septal defect closure using the Bard Clamshell Septal Umbrella. , 1996, The American journal of cardiology.

[5]  B. McManus,et al.  Biological response to Bard Clamshell Septal Occluders in the canine heart. , 1996, Circulation.

[6]  E. Sideris,et al.  Atrial septal defect occlusion with the buttoned device (a multi-institutional U.S. trial). , 1994, The American journal of cardiology.

[7]  R. Wilson,et al.  Experimental Atrial Septal Defect Closure With a New, Transcatheter, Self‐Centering Device , 1993, Circulation.

[8]  James M. Anderson,et al.  Chapter 19 Cardiovascular device retrieval and evaluation , 1993 .

[9]  J. Newburger,et al.  Transcatheter Closure of Patent Foramen Ovale After Presumed Paradoxical Embolism , 1992, Circulation.

[10]  A. Farb,et al.  Transient ischemic attacks after long-term clamshell occluder implantation for closure of atrial septal defect. , 1992, American heart journal.

[11]  J. F. Keane,et al.  Double-umbrella closure of atrial defects. Initial clinical applications. , 1990, Circulation.

[12]  J. F. Keane,et al.  Transcatheter closure of atrial septal defects. Experimental studies. , 1989, Circulation.

[13]  A. Rocchini,et al.  Transcatheter Atrial Septal Defect Closure: Preliminary Experience with the Rashkind Occluder Device , 1989 .

[14]  B. Risberg,et al.  Seeding of ePTFE carotid interposition grafts in sheep and dogs: species-dependent results. , 1988, Surgery.

[15]  J. F. Keane,et al.  Transcatheter umbrella closure of congenital heart defects. , 1987, Circulation.

[16]  J. Lock,et al.  "Intramural" residual interventricular defects after repair of conotruncal malformations. , 1994, Circulation.

[17]  E. Sideris,et al.  Transvenous atrial septal defect occlusion in piglets with a "buttoned" double-disk device. , 1990, Circulation.