The variability of shoulder motions recorded by means of palpation.

Objective. The objective of this methodological study is the quantification of the sources of variability in the recorded three-dimensional motions of the shoulder mechanism for comparative purposes. Background. The palpation and subsequent digitization of skeletal landmarks of the shoulder mechanism is a non-invasive and relatively easy method to quantify shoulder orientations. Comparison of individual motions is subject to the accuracy of the palpation method, the magnitude of kinematic redundancy of the shoulder mechanism and inter-subject differences in morphology and physiology. Quantification of these sources of variance i.e. the palpation error, motoric noise and inter-subject differences, demonstrated the accuracy of the method and the potential validity of the descriptive motion parameters, e.g. Cardan angles, in intra- and inter-individual studies for clinical, ergonomical and biomechanical studies. Methods. The orientations of the shoulder bones were recorded five times for each of five subjects by palpation and digitization of 12 skeletal landmarks for 10 equidistant arm elevation postures in the scapular plane. The orientations were described by means of Cardan angles. The palpation error was determined at a standardized initial rest position and expressed by Cardan angles for each recorded posture. Adding motoric noise and inter-subject differences gave the inter-individual variance. Results. The palpation error was approximately 2 °. The major recorded variance originated from motoric noise (±33%) and inter-subject difference (±55%). Conclusions. The palpation method is an accurate means of recording the three-dimensional orientations of the shoulder mechanism and for intra-individual studies. However, inter-subject variability is large.

[1]  Edward R. Valstar,et al.  Velocity effects on the scapulo-humeral rhythm. , 1998, Clinical biomechanics.

[2]  F. V. D. van der Helm,et al.  Geometry parameters for musculoskeletal modelling of the shoulder system. , 1992, Journal of biomechanics.

[3]  F. C. T. Helm,et al.  Analysis of the kinematic and dynamic behavior of the shoulder mechanism , 1994 .

[4]  G R Johnson,et al.  A method for the measurement of three-dimensional scapular movement. , 1993, Clinical biomechanics.

[5]  F. V. D. van der Helm,et al.  Three-dimensional recording and description of motions of the shoulder mechanism. , 1995, Journal of biomechanical engineering.

[6]  Savio Lau-Yuen Woo,et al.  Biomechanics of diarthrodial joints , 1990 .

[7]  F C van der Helm,et al.  The palpator: an instrument for measuring the positions of bones in three dimensions. , 1991, Journal of medical engineering & technology.

[8]  D. G. Watts,et al.  Spectral analysis and its applications , 1968 .

[9]  P Herberts,et al.  Biomechanical model of the human shoulder--I. Elements. , 1987, Journal of biomechanics.

[10]  J. G. Bonnin The Shoulder Girdle , 1951 .

[11]  Herman J. Woltring,et al.  Representation and calculation of 3-D joint movement , 1991 .

[12]  V. Mow,et al.  Stereophotogrammetric Determination of Joint Anatomy and Contact Areas , 1990 .

[13]  J A Sidles,et al.  Laxity of the normal glenohumeral joint: A quantitative in vivo assessment. , 1992, Journal of shoulder and elbow surgery.