ATP as a Marker for Surface Contamination of Biological Origin in Schools and as a Potential Approach to the Measurement of Cleaning Effectiveness

To address the need for a quantitative approach to the measurement of cleaning effectiveness, related to biologically derived surface contamination, three commercially available adenosine triphosphate (ATP) test systems were used to collect multiple samples measured in relative light units (RLUs) from 27 elementary schools in the southwestern United States before and after a standardized cleaning protocol. The database consisted of 6480 ATP measurements from four critical surfaces (student desktops, cafeteria tabletops, and restroom sinks and stall doors). Data was assessed according to ranges of ATP values before and after cleaning. Results showed the potential for such data to provide the basis for a standardized approach to the measurement of cleaning effectiveness, based on detection and quantification of pollutant loads of biological origin, across critical surfaces in school building environments. It is anticipated that verification of this data in school buildings across different geographic and climatic regions will lead to the establishment of “acceptable” ranges of ATP values that can be used as a practice-based approach to improving cleaning practices and contributing to healthier school environments.

[1]  Charles P. Gerba,et al.  Significance of Fomites in the Spread of Respiratory and Enteric Viral Disease , 2007, Applied and Environmental Microbiology.

[2]  K. Shelley,et al.  MRSA as a health concern in athletic facilities. , 2011, Journal of environmental health.

[3]  S. Stonecipher,et al.  How We Didn’t Clean Up Until We Washed Our Hands: Shigellosis in an Elementary and Middle School in North Texas , 2012, Southern medical journal.

[4]  U Haverinen-Shaughnessy,et al.  A preliminary study on the association between ventilation rates in classrooms and student performance. , 2006, Indoor air.

[5]  J. Lauer,et al.  Assessment of hygienic quality of surfaces in retail food service establishments based on microbial counts and real-time detection of ATP. , 2011, Journal of food protection.

[6]  U. Haverinen-Shaughnessy,et al.  Association between substandard classroom ventilation rates and students' academic achievement. , 2011, Indoor air.

[7]  H Humphreys,et al.  Is it really clean? An evaluation of the efficacy of four methods for determining hospital cleanliness. , 2009, The Journal of hospital infection.

[8]  D. Norbäck,et al.  Nasal patency and lavage biomarkers in relation to settled dust and cleaning routines in schools. , 1999, Scandinavian journal of work, environment & health.

[9]  K. Hiramatsu,et al.  Trial to control an outbreak of Panton-Valentine leukocidin-positive methicillin-resistant Staphylococcus aureus at a boarding school in Japan. , 2011, American journal of infection control.

[10]  Lennart Larsson,et al.  A longitudinal study of sick building syndrome among pupils in relation to microbial components in dust in schools in China. , 2011, The Science of the total environment.

[11]  Karin Foarde,et al.  Cleaning for Improved Indoor Air Quality: an Initial Assessment of Effectiveness , 1997 .

[12]  I. Nandrup-Bus Comparative studies of hand disinfection and handwashing procedures as tested by pupils in intervention programs. , 2011, American journal of infection control.