Damping Low-Frequency Oscillations Through VSC-HVdc Stations Operated as Virtual Synchronous Machines

With proper control methods, grid-connected power converters can mimic the dynamics of conventional synchronous generators (SGs), i.e., acting as virtual synchronous machines (VSMs), for improving the grid frequency stability and ensuring a smooth transition toward converter-dominated power systems. However, the integration of VSMs will inevitably influence the low-frequency oscillations (LFOs) in power grids which are usually caused by the interactions among SGs. This influence should be of concern especially when the VSM's capacity is similar to that of SG, e.g., operating voltage-source converter (VSC)-HVdc stations as VSMs. This paper investigates how the VSM affects LFOs in power systems by analyzing its equivalent damping torque. We show that with proper control design, VSMs can provide considerable positive damping torque to effectively damp LFOs in power grids. Particularly, using the damping torque analysis, the influences of virtual impedance and grid frequency detector (i.e., phase-locked loop) are elaborately studied so as to provide design guidelines for better damping LFOs. Finally, case studies of a two-area test system with integration of a VSM-based VSC-HVdc station verify the validity of the analysis.

[1]  Jon Are Suul,et al.  Impedance-compensated grid synchronisation for extending the stability range of weak grids with voltage source converters , 2016 .

[2]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.

[3]  Ying Chen,et al.  Static Synchronous Generator Model: A New Perspective to Investigate Dynamic Characteristics and Stability Issues of Grid-Tied PWM Inverter , 2016, IEEE Transactions on Power Electronics.

[4]  Qing-Chang Zhong,et al.  Synchronverters: Inverters That Mimic Synchronous Generators , 2011, IEEE Transactions on Industrial Electronics.

[5]  Yun Wei Li,et al.  Analysis, Design, and Implementation of Virtual Impedance for Power Electronics Interfaced Distributed Generation , 2011, IEEE Transactions on Industry Applications.

[6]  Massimo Bongiorno,et al.  Auto-normalizing Phase-Locked Loop for grid-connected converters , 2009, 2009 IEEE Energy Conversion Congress and Exposition.

[7]  V.G. Agelidis,et al.  VSC-Based HVDC Power Transmission Systems: An Overview , 2009, IEEE Transactions on Power Electronics.

[8]  Xiangning He,et al.  Analysis and Mitigation of Inverter Output Impedance Impacts for Distributed Energy Resource Interface , 2015, IEEE Transactions on Power Electronics.

[9]  Lennart Harnefors,et al.  Modeling of Three-Phase Dynamic Systems Using Complex Transfer Functions and Transfer Matrices , 2007, IEEE Transactions on Industrial Electronics.

[10]  Jon Are Suul,et al.  A Virtual synchronous machine implementation for distributed control of power transformers in SmartGrids , 2015 .

[11]  Deqiang Gan,et al.  Large-Scale Power System Robust Stability Analysis Based on Value Set Approach , 2017, IEEE Transactions on Power Systems.

[12]  Zhen Wang,et al.  Synchronous Instability Mechanism of P-f Droop-Controlled Voltage Source Converter Caused by Current Saturation , 2016, IEEE Transactions on Power Systems.

[13]  Jian Sun,et al.  Impedance shaping of three-phase grid-parallel voltage-source converters , 2012, 2012 Twenty-Seventh Annual IEEE Applied Power Electronics Conference and Exposition (APEC).

[14]  Miguel Castilla,et al.  Control of Power Converters in AC Microgrids , 2018, Microgrids Design and Implementation.

[15]  Jia Liu,et al.  Comparison of Dynamic Characteristics Between Virtual Synchronous Generator and Droop Control in Inverter-Based Distributed Generators , 2016, IEEE Transactions on Power Electronics.

[16]  P. Kundur,et al.  Definition and classification of power system stability IEEE/CIGRE joint task force on stability terms and definitions , 2004, IEEE Transactions on Power Systems.

[17]  Reza Iravani,et al.  Voltage-Sourced Converters in Power Systems: Modeling, Control, and Applications , 2010 .

[18]  Yushi Miura,et al.  Oscillation Damping of a Distributed Generator Using a Virtual Synchronous Generator , 2014, IEEE Transactions on Power Delivery.

[19]  L Harnefors,et al.  Proof and Application of the Positive-Net-Damping Stability Criterion , 2011, IEEE Transactions on Power Systems.

[20]  Jon Are Suul,et al.  Equivalence of Virtual Synchronous Machines and Frequency-Droops for Converter-Based MicroGrids , 2014, IEEE Transactions on Smart Grid.

[21]  P. Kundur,et al.  Power system stability and control , 1994 .

[22]  Kais Atallah,et al.  Trends in Wind Turbine Generator Systems , 2013, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[23]  Jon Are Suul,et al.  Virtual synchronous machines — Classification of implementations and analysis of equivalence to droop controllers for microgrids , 2013, 2013 IEEE Grenoble Conference.

[24]  Hans-Peter Nee,et al.  Power-Synchronization Control of Grid-Connected Voltage-Source Converters , 2010, IEEE Transactions on Power Systems.

[25]  Josep M. Guerrero,et al.  Conventional Synchronous Reference Frame Phase-Locked Loop is an Adaptive Complex Filter , 2015, IEEE Transactions on Industrial Electronics.

[26]  Yushi Miura,et al.  Power System Stabilization Using Virtual Synchronous Generator With Alternating Moment of Inertia , 2015, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[27]  Frede Blaabjerg,et al.  Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[28]  Jiabing Hu,et al.  Inertia Provision and Estimation of PLL-Based DFIG Wind Turbines , 2017, IEEE Transactions on Power Systems.

[29]  Florian Dörfler,et al.  Synchronization and transient stability in power networks and non-uniform Kuramoto oscillators , 2009, Proceedings of the 2010 American Control Conference.

[30]  Zhen Wang,et al.  A Virtual Synchronous Control for Voltage-Source Converters Utilizing Dynamics of DC-Link Capacitor to Realize Self-Synchronization , 2017, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[31]  Yunjie Gu,et al.  Reduced-Order Models for Representing Converters in Power System Studies , 2018, IEEE Transactions on Power Electronics.

[32]  Massimo Bongiorno,et al.  Stability Analysis of Two-Terminal VSC-HVDC Systems Using the Net-Damping Criterion , 2016, IEEE Transactions on Power Delivery.

[33]  Zhen Wang,et al.  Transient Stability Analysis and Control Design of Droop-Controlled Voltage Source Converters Considering Current Limitation , 2019, IEEE Transactions on Smart Grid.

[34]  T.C. Green,et al.  Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid , 2007, IEEE Transactions on Power Electronics.

[35]  Wanxing Sheng,et al.  Self-Synchronized Synchronverters: Inverters Without a Dedicated Synchronization Unit , 2014, IEEE Transactions on Power Electronics.

[36]  Qing-Chang Zhong,et al.  Virtual Synchronous Machines: A unified interface for grid integration , 2016, IEEE Power Electronics Magazine.

[37]  Marco Liserre,et al.  Grid Converters for Photovoltaic and Wind Power Systems , 2011 .

[38]  Frede Blaabjerg,et al.  Unified Impedance Model of Grid-Connected Voltage-Source Converters , 2018, IEEE Transactions on Power Electronics.

[39]  Bo Wen,et al.  Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters , 2016, IEEE Transactions on Power Electronics.