The HemoCue B-hemoglobin test system (HemoCue, Inc., Mission Viejo, CA) is a photometric method for rapid bedside determination of hemoglobin (Hb). We compared the performance of HemoCue measured Hb against Coulter STK-S (CSTK) measured Hb in chronic hemodialysis (HD) patients in two different settings. In the first setting, Hemocue analysis was performed by multiple HD technicians (n = 132). In the second setting, a nurse trained in proper specimen handling performed the HemoCue analysis (n = 74). Simultaneous measurement of Hb by the CSTK method was performed. First setting: Hb was 11.1 ± 1.66 (SD) g/dl by CSTK and 11.7 ± 2.29 g/dl by HemoCue. The HemoCue method consistently overestimated Hb by an average (SD) of 0.63 (1.267) g/dl (95% CI = 0.42 to 0.85). Hb was overestimated in 25.7% and underestimated in 2.3% of the patients by 1 g/dl or more. Thus, the HemoCue system was accurate within 1 g/dl only 72% of the time. Second setting: HemoCue overestimated Hb by an average (SD) of 0.29 (0.52) g/dl (95% CI, 0.17 to 0.41). Only 4% of all patients had errors in estimation of 1 g/dl or more. Thus, HemoCue was accurate in 96% of the patients within 1 g/dl. After reviewing the two protocols, the primary difference in the two studies was the technique used to obtain the specimens. When performed properly, Hb testing using the HemoCue testing system had a high level of agreement with CSTK. Appropriate training in specimen handling, as well as test performance, will increase accuracy and reliability of bedside hemoglobinometry.
[1]
A Comparison of Four Bedside Methods of Hemoglobin Assessment During Cardiac Surgery
,
1995,
Anesthesia and analgesia.
[2]
D. Altman,et al.
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
,
1986,
The Lancet.
[3]
T. Short,et al.
A Clinical Evaluation of the Hemocue Haemoglobinometer using Capillary, Venous and Arterial Samples
,
1992,
Anaesthesia and intensive care.
[4]
R. Neville.
Evaluation of portable haemoglobinometer in general practice.
,
1987,
British medical journal.
[5]
A. Beckett,et al.
AKUFO AND IBARAPA.
,
1965,
Lancet.
[6]
B Lundberg,et al.
Evaluation of "HemoCue," a new device for determining hemoglobin.
,
1986,
Clinical chemistry.
[7]
S. Ehrmeyer,et al.
Application of the Department of Health and Human Services proposed waived status requirements for in vitro diagnostic testing devices: case study.
,
1997,
Clinical chemistry.
[8]
L. M. Anderson,et al.
Measurement of haemoglobin using single drops of skin puncture blood: is precision acceptable?
,
1998,
Journal of clinical pathology.