Two-line thermometry and H2O measurement for reactive mixtures in rapid compression machine near 7.6 μm

Abstract A much desired, direct, in situ, diagnostics technique is implemented to measure time variations of temperature and water concentration for a reactive mixture in a rapid compression machine (RCM) using quantum cascade laser absorption spectroscopy near 7.6 μm. The temperature measurements in the RCM are successfully conducted for an end of compression pressure of PC ∼ 11.5 bar and an end of compression temperature of TC ∼ 1022 K for H2/O2/Ar mixtures with (0.5% by mole in the reactive mixture) and without water doping. For all cases investigated, the molar percentages of H2 and O2 in the reactive mixture are respectively kept at 3% while the balance is Ar, in order to modulate the extent of post-ignition pressure rise. Absorption lines of water at 1316.55 cm−1 and 1316.97 cm−1 are used in this study for the measurements. A six-pass setup inside the RCM is implemented for the reactive experiments. For determining the line broadening parameters of water in the range of 1316.4–1317.8 cm−1 with H2 or O2 as a bath gas, a six-pass, 50.8 mm Herriott cell is used in the calibration experiments. The broadening parameters are measured in the pressure range of 300–650 Torr, while the Herriott cell is heated uniformly to temperatures of 460, 500, and 530 K, respectively. With the measured line broadening parameters of water in the bath gases of interest, the temperature and water concentration histories in the RCM runs are experimentally determined. In addition, the experimental results are compared with the simulations with detailed chemistry. Reasonable agreement is found, thereby demonstrating the utility of this mid-IR absorption spectroscopy in RCM experiments. The uncertainties of the associated measurements of temperature and water concentration are also discussed.

[1]  Herwig Kogelnik,et al.  Off-Axis Paths in Spherical Mirror Interferometers , 1964 .

[2]  C. Plymate,et al.  H2-broadened H216O in four infrared bands between 55 and 4045 cm−1 , 1996 .

[3]  Frans J. M. Harren,et al.  Sub-part-per-billion monitoring of nitric oxide by use of wavelength modulation spectroscopy in combination with a thermoelectrically cooled, continuous-wave quantum cascade laser. , 2006, Optics letters.

[4]  Frans J. M. Harren,et al.  Quantum cascade laser-based carbon monoxide detection on a second time scale from human breath , 2006 .

[5]  M. Oehlschlaeger,et al.  A mid-infrared scanned-wavelength laser absorption sensor for carbon monoxide and temperature measurements from 900 to 4000 K , 2010 .

[6]  Ronald K. Hanson,et al.  In situ combustion measurements of H2O and temperature near 2.5 µm using tunable diode laser absorption , 2008 .

[7]  David D. Nelson,et al.  Pulsed quantum cascade laser instrument with compact design for rapid, high sensitivity measurements of trace gases in air , 2008 .

[8]  Chih-Jen Sung,et al.  Aerodynamics inside a rapid compression machine , 2006 .

[9]  Philip A. Martin,et al.  A CO2 sensor based upon a continuous-wave thermoelectrically- cooled quantum cascade laser , 2011 .

[10]  Hugh W. Coleman,et al.  Experimentation and Uncertainty Analysis for Engineers , 1989 .

[11]  S. Corzine,et al.  Widely tunable mode-hop free external cavity quantum cascade lasers for high resolution spectroscopy and chemical sensing , 2008 .

[12]  Ronald K. Hanson,et al.  Temperature-Dependent Collision-Broadening Parameters of H2O Lines in the 1.4-μm Region Using Diode Laser Absorption Spectroscopy , 1994 .

[13]  Timothy Day,et al.  External cavity widely tunable quantum cascade laser based hollow waveguide gas sensors for multianalyte detection , 2009 .

[14]  Chih-Jen Sung,et al.  Vortex Formation in a Rapid Compression Machine: Influence of Physical and Operating Parameters , 2012 .

[15]  Yu Zhang,et al.  Ignition Delay Study of Moist Hydrogen/Oxidizer Mixtures Using a Rapid Compression Machine , 2012 .

[16]  Chih-Jen Sung,et al.  A RAPID COMPRESSION MACHINE FOR CHEMICAL KINETICS STUDIES AT ELEVATED PRESSURES AND TEMPERATURES , 2007 .

[17]  Ronald K. Hanson,et al.  In situ absorption sensor for NO in combustion gases with a 5.2 μm quantum-cascade laser , 2011 .

[18]  Yiding Wang,et al.  Design and characteristics of quantum cascade laser-based CO detection system , 2009 .

[19]  Robert A. Toth,et al.  Oxygen broadening parameters of water vapor: 1212–2136 cm−1 , 2003 .

[20]  Laurence S. Rothman,et al.  Total internal partition sums for molecular species in the 2000 edition of the HITRAN database , 2003 .

[21]  Ronald K. Hanson,et al.  An improved H2/O2 mechanism based on recent shock tube/laser absorption measurements , 2011 .

[22]  Jonathan Tennyson,et al.  HITEMP, the high-temperature molecular spectroscopic database , 2010 .

[23]  Vincenzo Spagnolo,et al.  Quantum Cascade Laser-Based Photoacoustic Sensor for Trace Detection of Formaldehyde Gas , 2009, Sensors.