Arterial pulse wave reflection as feedback

Traditionally, input impedance (Z/sub in/) has been used to characterize the global dynamic properties of an arterial system independent of properties of the heart. Defined as the relationship of pressure and flow at the entrance of an arterial system, it describes the ability of an arterial system to dynamically impede blood flow. Recently, a new description has been developed that also characterizes the arterial system independent of properties of the heart. Apparent arterial compliance (C/sub app/) is defined as the dynamic relationship of input pressure and volume stored in an arterial system, and describes the ability of the arterial system to dynamically store blood. Both Z/sub in/ and C/sub app/ are influenced by pulse wave propagation and reflection. However, the functional form of C/sub app/ lends itself to describing the arterial system in terms of negative feedback. Pulse wave reflection decreases the pulsatile volume stored (gain) at low frequencies, but increases the range of frequencies (bandwidth) in which the pulsatile volume is determined by total arterial compliance. This paper illustrates, by simple analytical formula, large-scale arterial system modeling, and direct analysis of data, how this conceptualization of reflection offers a new means to interpret changes in arterial system dynamics resulting from changes in arterial compliance.

[1]  J. Womersley,et al.  An Elastic Tube Theory of Pulse Transmission and Oscillatory Flow in Mammalian Arteries , 1957 .

[2]  K P Brin,et al.  Arterial hemodynamics in human hypertension. , 1986, The Journal of clinical investigation.

[3]  Douglas A. Hettrick,et al.  True Arterial System Compliance Estimated From Apparent Arterial Compliance , 2000, Annals of Biomedical Engineering.

[4]  M. Jaffrin,et al.  Aortic input impedance in normal man and arterial hypertension: its modification during changes in aortic pressure. , 1982, Cardiovascular research.

[5]  N Westerhof,et al.  Normalized input impedance and arterial decay time over heart period are independent of animal size. , 1991, The American journal of physiology.

[6]  K B Campbell,et al.  Effective distributed compliance of the canine descending aorta estimated by modified T-tube model. , 1993, The American journal of physiology.

[7]  M F O'Rourke,et al.  Pressure and flow waves in systemic arteries and the anatomical design of the arterial system. , 1967, Journal of applied physiology.

[8]  John G. Webster,et al.  Medical Instrumentation: Application and Design , 1997 .

[9]  A Noordergraaf,et al.  Similar pressure pulse propagation and reflection characteristics in aortas of mammals. , 1991, The American journal of physiology.

[10]  R. Cox Pressure dependence of the mechanical properties of arteries in vivo. , 1975, The American journal of physiology.

[11]  A model of the arterial wall. , 1973, Journal of biomechanics.

[12]  N. Westerhof,et al.  Forward and backward waves in the arterial system. , 1972, Cardiovascular research.

[13]  M K Sharp,et al.  Aortic input impedance in infants and children. , 2000, Journal of applied physiology.

[14]  A. Noordergraaf Circulatory System Dynamics , 1978 .

[15]  A Noordergraaf,et al.  Constructive and destructive addition of forward and reflected arterial pulse waves. , 2001, American journal of physiology. Heart and circulatory physiology.

[16]  M. Chang,et al.  Arterial Hemodynamics in Human Hypertension: Effects of Adrenergic Blockade , 1991, Circulation.

[17]  M. O'Rourke,et al.  Input Impedance of the Systemic Circulation , 1967, Circulation research.

[18]  W. Young,et al.  Infinite number of solutions to the hemodynamic inverse problem. , 2001, American journal of physiology. Heart and circulatory physiology.

[19]  W. Nichols,et al.  Determinants of isolated systolic hypertension in the elderly , 1992, Journal of hypertension. Supplement : official journal of the International Society of Hypertension.

[20]  A Noordergraaf,et al.  Analog studies of the human systemic arterial tree. , 1969, Journal of biomechanics.

[21]  D. A. Mcdonald,et al.  The relation of pulsatile pressure and flow in the pulmonary vascular bed , 1961, The Journal of physiology.

[22]  K Sagawa,et al.  Translation of Otto Frank's paper "Die Grundform des Arteriellen Pulses" Zeitschrift für Biologie 37: 483-526 (1899). , 1990, Journal of molecular and cellular cardiology.

[23]  M. G. Taylor,et al.  Use of Random Excitation and Spectral Analysis in the Study of Frequency‐Dependent Parameters of the Cardiovascular System , 1966, Circulation research.

[24]  M. O'Rourke Steady and pulsatile energy losses in the systemic circulation under normal conditions and in simulated arterial disease. , 1967, Cardiovascular research.

[25]  A Noordergraaf,et al.  Arterial viscoelasticity: a generalized model. Effect on input impedance and wave travel in the systematic tree. , 1970, Journal of biomechanics.

[26]  P. Pagel,et al.  Differential Effects of Isoflurane and Halothane on Aortic Input Impedance Quantified Using a Three-element Windkessel Model , 1995, Anesthesiology.

[27]  A Noordergraaf,et al.  Mammalian hemodynamics: a new similarity principle. , 1979, Journal of theoretical biology.

[28]  A Noordergraaf,et al.  Apparent arterial compliance. , 1998, The American journal of physiology.

[29]  R W STACY,et al.  Mechanical impedance of the dog's hind leg to pulsatile blood flow. , 1956, The American journal of physiology.