Novel Methods for Assessing the Protection Impacts of Distributed Generation in Distribution Network Planning

Recent developments in energy policies and prices have directed an increasing amount of interest at exploiting small energy resources. This small-scale power generation evidently needs to be connected to the present power distribution system with simple manners in order to be economically competitive. As the distribution system has initially been built for simple one-way power delivery, interconnecting small generators requires new thinking and new methods for operating the network. Small-scale generators located on the distribution level are generally referred to as distributed generation (DG). There are several clear consequences for locating DG in the distribution network that need to be taken into account. Probably the most critical concern is the operation of network protection. This can be stated as protection malfunctions can result in safety hazards. The presence of DG affects for instance short-circuit current amplitudes, which can further disturb the operation of feeder protection. DG may also result in failing reclosings or situations in which the DG unit maintains the voltage alone in the network. These situations must be avoided. This thesis focuses on the network protection impacts of DG. It aims to provide new tools and methods for including the impacts of DG correctly in network planning methods. This can be achieved by bringing the research observations towards the practical level of network planning. To help form a precise image on the subject, the typical DG-related protection problems are described and analysed. Simulation tools have been used to study the phenomena. A perspective of distribution network planning is maintained throughout the thesis. The information systems applied for planning purposes are also considered. Development needs created by DG are especially focused on. The most important observations of this thesis relate to the contradictions between protection selectivity and sensitivity; to the problematic nature of differentiating between faults that require rapid actions and other disturbances that should not result in any action. At the present situation, it may be possible to trip the DG units too sensitively in the name of network safety. However, as the DG becomes more significant for the power system, more coordination will be needed in the future. An efficient coordination of protection devices during all possible situations is beneficial to all parties. The thesis shows the significance of performing certain studies during the interconnection process of a new DG unit. The sequence of the studies performed can also be essential depending on the case. The thesis proposes a procedure for

[1]  Roberto Benato,et al.  Application of distribution line carrier-based protection to prevent DG islanding: an investigating procedure , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[2]  M. Steurer,et al.  Development of a unified design, test, and research platform for wind energy systems based on hardware-in-the-loop real time simulation , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[3]  Kari Mäki,et al.  Effect of wind power based distributed generation on protection of distribution network , 2004 .

[4]  Chris Marnay,et al.  Integration of distributed energy resources. The CERTS Microgrid Concept , 2002 .

[5]  B. Gotzig,et al.  Protection of embedded generation connected to a distribution network and loss of mains detection , 2001 .

[6]  A. S. Jhutty Embedded generation and the public electricity system , 1998 .

[7]  Goran Strbac,et al.  Distributed Generation in Electricity Markets, its impact on Distribution System Operators, and the role of Regulatory and Commercial Arrangements , 2006 .

[8]  Y. Baghzouz General rules for distributed generation - feeder interaction , 2006, 2006 IEEE Power Engineering Society General Meeting.

[9]  Peter Crossley,et al.  Protection and control of networks with distributed generators capable of operating in islanded mode , 2004 .

[10]  J.C.M. Vieira,et al.  Efficient coordination of ROCOF and frequency relays for distributed generation protection by using the application region , 2006, IEEE Transactions on Power Delivery.

[11]  L.K. Kumpulainen,et al.  Aspects of the effects of distributed generation in single-line-to-earth faults , 2005, 2005 International Conference on Future Power Systems.

[12]  Nouredine HADJSAID,et al.  CASE STUDIES ON THE OPERATING OF 20 KV DISTRIBUTION NETWORK WITH LARGE- SCALE LOW-VOLTAGE DISPERSED GENERATORS , 2003 .

[13]  T. R. Sims,et al.  Investigation of potential islanding of a self-commutated static power converter in photovoltaic systems , 1990 .

[14]  Wilsun Xu,et al.  Comparative analysis between ROCOF and vector surge relays for distributed generation applications , 2005, IEEE Transactions on Power Delivery.

[15]  Juan A. Martinez-Velasco,et al.  EMTP Model for Analysis of Distributed Generation Impact on Voltage Sags , 2007 .

[16]  J. R. McDonald,et al.  Performance analysis of the ROCOF and vector shift methods using a dynamic protection modeling approach , 2006 .

[17]  E. Lakervi,et al.  Present status in applying mathematical planning methods in AM/FM-GIS systems , 1997 .

[18]  Yahia Baghzouz Voltage Regulation and Overcurrent Protection Issues in Distribution Feeders with Distributed Generation - A Case Study , 2005, Proceedings of the 38th Annual Hawaii International Conference on System Sciences.

[19]  K. K. Li,et al.  Protection relay coordination on ring-fed distribution network with distributed generations , 2002, 2002 IEEE Region 10 Conference on Computers, Communications, Control and Power Engineering. TENCOM '02. Proceedings..

[20]  E.F. El-Saadany,et al.  Safe controlled islanding of inverter based distributed generation , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[21]  Nick Jenkins,et al.  Embedded Generation (Power & Energy Ser. 31) , 2000 .

[22]  Ismail Kasikci Short Circuits in Power Systems: A Practical Guide to IEC 60909-0: A Practical Guide to IEC 60909 , 2002 .

[23]  Peter E. Sutherland Protective device coordination in an industrial power system with multiple sources , 1996 .

[24]  R. Kuffel,et al.  Real time digital simulation for control and protection system testing , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[25]  P. Jarventausta,et al.  Problems related to Islanding Protection of Distributed Generation in Distribution Network , 2007, 2007 IEEE Lausanne Power Tech.

[26]  D. Kunda,et al.  Electrical impact of a NUG under 5 MW rating when connected to a distribution feeder with various transformer connections , 1994, Proceedings of Industrial and Commercial Power Systems Conference.

[27]  S. K. Salman,et al.  Monitoring changes in system variables due to islanding condition and those due to disturbances at the utilities' network , 1999, 1999 IEEE Transmission and Distribution Conference (Cat. No. 99CH36333).

[28]  Wilsun Xu,et al.  A practical method for assessing the effectiveness of vector surge relays for distributed generation applications , 2004, IEEE Transactions on Power Delivery.

[29]  L.A. Kojovic,et al.  Summary of Distributed Resources Impact on Power Delivery Systems , 2008, IEEE Transactions on Power Delivery.

[30]  Kimmo Kauhaniemi,et al.  LOSS-OF-MAINS PROTECTION - STILL AN ISSUE WITH DISTRIBUTED GENERATION , 2007 .

[31]  Emilio Ghiani,et al.  Distributed generation and intentional islanding: Effects on reliability in active networks , 2005 .

[32]  P. Pohjanheimo,et al.  Steady state modeling of custom power components in power distribution networks , 2000, 2000 IEEE Power Engineering Society Winter Meeting. Conference Proceedings (Cat. No.00CH37077).

[33]  B. Fox,et al.  Loss of mains detection for embedded generation by system impedance monitoring , 1997 .

[34]  Roger C. Dugan,et al.  Electric Distribution Protection Problems Associated with the Interconnection of Small Dispersed Generation Devices , 1984, IEEE Power Engineering Review.

[35]  J.C. Gomez,et al.  Coordination of voltage sag and overcurrent protection in DG systems , 2005, IEEE Transactions on Power Delivery.

[36]  Loo Chin Koon Interconnection of embedded generation: The Malaysian experience , 2005 .

[37]  L. A. Kojovic,et al.  Integration of distributed generation in a typical USA distribution system , 2001 .

[38]  A.G. Gonzalez Rodriguez,et al.  PSCAD based simulation of the connection of a wind generator to the network , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).

[39]  Minwon Park,et al.  A novel real-time simulation technique of photovoltaic generation systems using RTDS , 2004, IEEE Transactions on Energy Conversion.

[40]  S. K. Salman,et al.  Investigating the impact of embedded generation on relay settings of utilities electrical feeders , 2001 .

[41]  Ehab F. El-Saadany,et al.  Impact of DG interface control on islanding detection and nondetection zones , 2006 .

[42]  Ljubomir A. Kojovic Modeling techniques for studying DG interconnections to distribution systems , 2005 .

[43]  Kari Mäki,et al.  Protection requirement graph for interconnection of distributed generation on distribution level , 2007 .

[44]  E. J. Holmes,et al.  Electricity Distribution Network Design , 1989 .

[45]  A. Girgis,et al.  Effect of distributed generation on protective device coordination in distribution system , 2001, LESCOPE 01. 2001 Large Engineering Systems Conference on Power Engineering. Conference Proceedings. Theme: Powering Beyond 2001 (Cat. No.01ex490).

[46]  Ari Nikander ASPECTS OF CONNECTING A SMALL-SCALE HYDROELECTRIC POWER PLANT IN AN MV DISTRIBUTION NETWORK - A SIMULATION STUDY , 2007 .

[47]  Abram Perdana,et al.  Fault simulation of wind turbines using commercial simulation tools , 2005 .

[48]  W. G. Hartmann How to nuisance trip distributed generation , 2003, Rural Electric Power Conference, 2003.

[49]  A. Y. Chikhani,et al.  Intention islanding of distributed generation for reliability enhancement , 2003, CIGRE/IEEE PES International Symposium Quality and Security of Electric Power Delivery Systems, 2003. CIGRE/PES 2003..

[50]  Daisuke Iioka,et al.  Effect of fault current limiter installed in customer system on suppression of fault current and voltage sag , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[51]  P.P. Barker,et al.  Application of diesel generation at Hawaiian electric substations for power system support , 2006, 2006 IEEE Power Engineering Society General Meeting.

[52]  Grega Bizjak,et al.  Behavior of small hydroelectric power plant generators during the fault in distribution network (digital simulation study) , 2001, 2001 IEEE/PES Transmission and Distribution Conference and Exposition. Developing New Perspectives (Cat. No.01CH37294).

[53]  K.K. Li,et al.  Intelligent method for protection coordination , 2004, 2004 IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies. Proceedings.

[54]  D. Lowe,et al.  A Real-Time Platform for Teaching Power System Control Design , 2005 .

[55]  L.K. Kumpulainen,et al.  Analysis of the impact of distributed generation on automatic reclosing , 2004, IEEE PES Power Systems Conference and Exposition, 2004..

[56]  KARI MÄKI Blinding of Feeder Protection caused by Distributed Generation in Distribution Network , 2005 .

[57]  Junji Tamura,et al.  Transient stability simulation of power system including wind generator by PSCAD/EMTDC , 2001, 2001 IEEE Porto Power Tech Proceedings (Cat. No.01EX502).

[58]  F. Iliceto,et al.  Modelling and computer simulation of dispersed generation in distribution networks. Measures to prevent disconnection during system disturbances , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[59]  Inmaculada Zamora,et al.  Connection criteria at the distribution network for distributed generation , 2007 .

[60]  M.Y. Vaziri,et al.  Effects of distributed generation (DG) interconnections on protection of distribution feeders , 2006, 2006 IEEE Power Engineering Society General Meeting.

[61]  Lauri Kumpulainen,et al.  DISTRIBUTED GENERATION AND RECLOSING COORDINATION , 2004 .

[62]  Sung-Il Jang,et al.  An islanding detection method for distributed generations using voltage unbalance and total harmonic distortion of current , 2004, IEEE Transactions on Power Delivery.

[63]  D. ARDITO,et al.  Impact of Distributed Generation on Italian Distribution Network Protection , 2005 .

[64]  J. E. Kim,et al.  Islanding detection method of distributed generation units connected to power distribution system , 2000, PowerCon 2000. 2000 International Conference on Power System Technology. Proceedings (Cat. No.00EX409).

[65]  Roger C. Dugan,et al.  Distributed generation , 2002 .

[66]  A. Petterteig,et al.  Analysis of Fault Detection and Location in Medium Voltage Radial Networks with Distributed Generation , 2007, 2007 IEEE Lausanne Power Tech.

[67]  Alberto Borghetti,et al.  Dispersed generators interfaced with distribution systems: dynamic response to faults and perturbations , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[68]  B. Fox,et al.  Unsymmetrical faults and their potential for nuisance tripping of embedded generators , 2001 .

[69]  Paul M. Anderson Power System Protection , 1998 .

[70]  Zeng Xiangjun,et al.  Multi-agents based protection for distributed generation systems , 2004, 2004 IEEE International Conference on Electric Utility Deregulation, Restructuring and Power Technologies. Proceedings.

[71]  Pekka Verho,et al.  New requirements for system protection caused by distributed generation , 2005 .

[72]  K. P. Wong,et al.  Multi-agent application of substation protection coordination with distributed generators , 2005 .

[73]  Wei-Jen Lee,et al.  Impact Study on Intentional Islanding of Distributed Generation Connected to a Radial Subtransmission System in Thailand's Electric Power System , 2006, IEEE Transactions on Industry Applications.

[74]  Toshihisa Funabashi,et al.  Integration of fault current limiters in power distribution networks , 2004 .

[75]  L. van der Sluis,et al.  Real-time simulation to study the impact of renewable energy in power systems , 2005, 2005 International Conference on Future Power Systems.

[76]  M. M. Elkateb,et al.  Coordinating protection and control of dispersed generation , 1993 .

[77]  S. K. Salman,et al.  New loss of mains detection algorithm for embedded generation using rate of change of voltage and changes in power factors , 2001 .

[78]  E.F. El-Saadany,et al.  Intentional islanding of distributed generation , 2005, IEEE Power Engineering Society General Meeting, 2005.

[79]  B. Bletterie,et al.  Unintentional islanding in distribution grids with a high penetration of inverter-based DG: Probability for islanding and protection methods , 2005, 2005 IEEE Russia Power Tech.

[80]  JAMES PATTON,et al.  Analysis of Utility Protection Problems Associated with Small Wind Turbine Interconnections , 1982, IEEE Transactions on Power Apparatus and Systems.

[81]  R. Caldon CARRIER SIGNAL-BASED PROTECTION TO PREVENT DISPERSED GENERATION ISLANDING ON MV SYSTEMS , 2003 .

[82]  Louie J. Powell An industrial view of utility cogeneration protection requirements , 1988 .

[83]  M.T. Doyle,et al.  Reviewing the impacts of distributed generation on distribution system protection , 2002, IEEE Power Engineering Society Summer Meeting,.