Dielectric Loss Factor Measurement in Power Systems Based on Sampling Sequence Reconstruction Approach

Dielectric loss factor (DLF) is an important parameter to reflect the insulation condition of a high voltage capacitive equipment, which is widely installed in power systems. Hence, the accuracy of DLF measurement will directly affect the safety and stability of the power grid. This paper proposed a new algorithm based on sampling sequence reconstruction approach to accurately measure the DLF without being affected by asynchronous sampling and noise. The proposed method first estimates the fundamental frequency of power grid through the operational processing of voltage or current sampling sequence by weighted iteration with the composite trapezoidal rule. And then, the equivalent synchronous sampling sequences of the voltage and current in one cycle are constructed by using the estimated frequency and original sampling sequences through cubic spline interpolation. Finally, the fast Fourier transform results of the equivalent sequences are applied to obtain the value of the DLF. Simulations and experimental results show the effectiveness and practicability of the proposed method.

[1]  W. McDermid,et al.  A digital technique for the on-line measurement of dissipation factor and capacitance , 2001 .

[2]  Kang Wang,et al.  Fast Measurement of Dielectric Loss Angle With Time-Domain Quasi-Synchronous Algorithm , 2015, IEEE Transactions on Instrumentation and Measurement.

[3]  A. Cruz Serra,et al.  New Spectrum Leakage Correction Algorithm for Frequency Estimation of Power System Signals , 2009, IEEE Transactions on Instrumentation and Measurement.

[4]  W. Marsden I and J , 2012 .

[5]  Li Zhang,et al.  Definition of Instantaneous Dielectric Loss Factor and Digital Algorithm for Online Monitoring , 2009, IEEE Trans. Instrum. Meas..

[6]  Xu Zhi-niu Simulation Analysis of Dielectric Loss Angle Measured by the Blackman-Harris Window Interpolation Algorithm , 2007 .

[7]  Zhaosheng Teng,et al.  Harmonic Phasor Analysis Based on Improved FFT Algorithm , 2011, IEEE Transactions on Smart Grid.

[8]  Tan Kexiong Present Situation and Prospects of Condition Monitoring and Fault Diagnosis Technology for Electrical Equipments , 2003 .

[9]  Wŏn-yŏng Yang,et al.  Applied Numerical Methods Using MATLAB , 2005 .

[10]  T. Grandke Interpolation Algorithms for Discrete Fourier Transforms of Weighted Signals , 1983, IEEE Transactions on Instrumentation and Measurement.

[11]  Wang Weile Higher-order sine fitting algorithm for dielectric loss measurement , 2001 .

[12]  Fan Xingming,et al.  The measurement method of power capacitor tanδ based on Kaiser-window , 2012, 2012 International Conference and Exposition on Electrical and Power Engineering.

[13]  Xu Zhi-niu Analysis of Dielectric Loss Angle Measurement by Hanning Windowing Interpolation Algorithm Based on FFT , 2006 .

[14]  Zhaosheng Teng,et al.  Dielectric loss factor measurement based on nuttall self-convolution window phase difference correction , 2009, 2009 9th International Conference on Electronic Measurement & Instruments.

[15]  Zhaosheng Teng,et al.  Parameter Estimation of Power System Signals Based on Cosine Self-Convolution Window With Desirable Side-Lobe Behaviors , 2011, IEEE Transactions on Power Delivery.

[16]  Yong Wang,et al.  Simple Interpolated FFT Algorithm Based on Minimize Sidelobe Windows for Power-Harmonic Analysis , 2011, IEEE Transactions on Power Electronics.

[17]  S. Dyer,et al.  Cubic-spline interpolation. 1 , 2001 .

[18]  V. Jain,et al.  High-Accuracy Analog Measurements via Interpolated FFT , 1979, IEEE Transactions on Instrumentation and Measurement.

[19]  Qingmin Li,et al.  Definition and digital algorithms of dielectric loss factor for condition monitoring of high voltage power equipment with harmonics emphasis , 2004, IEEE PES Power Systems Conference and Exposition, 2004..

[20]  Adam Cichy Non-bridge circuit with double quasi-balancing for measurement of dielectric loss factor , 2013 .

[21]  Liping Guo,et al.  Notice of RetractionResearch on tanδ on-line monitoring method , 2011, 2011 International Conference on Electrical and Control Engineering.

[22]  B. Hague,et al.  Alternating current bridge methods , 1943 .

[23]  Gehao Sheng,et al.  Digital algorithm based on orthogonal decomposition for measurement of dielectric loss factor , 2008 .

[24]  Qin Lijun,et al.  Application of hamming windowed interpolated DFT algorithm based on modified ideal sampling frequency in on-line measuring dielectric loss angle , 2011, 2011 4th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT).

[25]  Zhou Hao High-accuracy Estimation of Dielectric Loss Angle Using the Improved Blackman-windowed Interpolated Algorithm , 2008 .

[26]  Wenwu Cao,et al.  Applied Numerical Methods Using MATLAB®: Yang/Applied Numerical MATLAB , 2005 .

[27]  Adly Girgis,et al.  A Quantitative Study of Pitfalls in the FFT , 1980, IEEE Transactions on Aerospace and Electronic Systems.