A reevaluation of corneal endothelial permeability to fluorescein.

The permeability of the corneal endothelium and its aqueous-cornea distribution ratio were reevaluated in the rabbit eye. Both parameters were determined in an individual eye by applying the dye first by iontophoresis and then by intravitreal injection, which allows the influence of fluorescein glucuronide on the fluorophotometric measurements to be excluded. The corneal endothelial permeability coefficient was 5.13 +/- 1.64 X 10(-4) cm min-1, and the aqueous-cornea distribution ratio was 0.25 +/- 0.06 (mean +/- S.D., n = 11) on the average, and the former was considerably greater than the previous results, while the latter was considerably smaller.

[1]  T. Tanishima,et al.  Endothelial wound-healing of monkey cornea: fluorophotometric and specular microscopic studies. , 1984, Japanese journal of ophthalmology.

[2]  R. Brubaker,et al.  Method of measuring aqueous humor flow and corneal endothelial permeability using a fluorophotometry nomogram. , 1979, Investigative ophthalmology & visual science.

[3]  M. Araie,et al.  Permeability of the Human Corneal Endothelium to Fluorescein , 1981 .

[4]  S. C. Chen,et al.  Determination of fluorescein and fluorescein monoglucuronide excreted in urine. , 1980, Chemical & pharmaceutical bulletin.

[5]  D. Maurice,et al.  THE DIFFUSION OF FLUORESCEIN IN THE LENS. , 1964, Experimental eye research.

[6]  S. Waltman,et al.  In vivo studies of human corneal endothelial permeability. , 1970, American journal of ophthalmology.

[7]  D. Maurice,et al.  Endothelial permeability of the living cornea to fluorescein. , 1974, Investigative ophthalmology.

[8]  D. Maurice,et al.  A Simple Optical Apparatus for Measuring the Corneal Thickness, and the Average Thickness of the Human Cornea * , 1951, The British journal of ophthalmology.

[9]  S. Mishima,et al.  Clinical investigations on the corneal endothelium-XXXVIII Edward Jackson Memorial Lecture. , 1982, American journal of ophthalmology.

[10]  R. Brubaker,et al.  Fluorescent, physiological and pharmacokinetic properties of fluorescein glucuronide. , 1985, Experimental eye research.

[11]  L. Sallmann Sulfadiazine Iontophoresis in Pyocyaneus Infection of Rabbit Cornea , 1942 .

[12]  B. Schwartz,et al.  The visual evoked potential in glaucoma and ocular hypertension: effects of check size, field size, and stimulation rate. , 1983, Investigative ophthalmology & visual science.

[13]  D. Maurice,et al.  The Cornea and Sclera , 1962 .

[14]  R. Brubaker,et al.  The permeability of the corneal endothelium to fluorescein in the normal human eye. , 1984, Current eye research.

[15]  D. Maurice,et al.  A fresh look at iontophoresis. , 1984, Archives of ophthalmology.

[16]  K G Romanchuk,et al.  Fluorescein. Physiochemical factors affecting its fluorescence. , 1982, Survey of ophthalmology.

[17]  M. Araie Aqueous Humor Dynamics in Man as Studied by Oral Fluorescein , 1980 .

[18]  D. Maurice,et al.  New methods of measuring the rate of aqueous flow in man with fluorescein. , 1966, Experimental eye research.