Second- and third-zone performance assessment of a symmetrical component based improved fault impedance estimation method

Abstract The performance assessment of a symmetrical component based fault impedance estimation method that has previously been proposed by the authors is discussed in this paper. A brief review of the proposed method is given. The personal computer based Alternative Transient Program was used in these performance assessment studies. Voltage and current signals for various fault conditions were generated by simulating different types of fault on a selected transmission line of a sample power system. These signals were processed, sampled, and used in the proposed method. The apparent impedance of the protected transmission line from the relay location up to the fault point was calculated using the proposed method. These impedance estimates were inserted in R − X plane characteristics to determine the suitability of the proposed method for digital distance protection of the second and third zones. The results of these performance assessment studies are presented and discussed in the paper.

[1]  Alan V. Oppenheim,et al.  Discrete-Time Signal Pro-cessing , 1989 .

[2]  Tadeusz Łobos Non-recursive methods for on-line estimation of voltages or currents and symmetrical components using Kalman filter theory , 1985 .

[3]  Alessandro Ferrero,et al.  A simplified algorithm for digital distance protection based on Fourier techniques , 1989 .

[4]  D. L. Waikar,et al.  Symmetrical component based improved fault impedance estimation method for digital distance protection Part II. Computational aspects and validation , 1993 .

[5]  M.S. Sachdev,et al.  Kalman Filtering Applied to Power System Measurements Relaying , 1985, IEEE Transactions on Power Apparatus and Systems.

[6]  D. L. Waikar,et al.  First-zone performance assessment of a symmetrical component based improved fault impedance estimation method , 1993 .

[7]  H. K. Verma,et al.  New algorithms for microprocessor-based distance relaying , 1988 .

[8]  T. Hlibka,et al.  Fundamental basis for distance relaying with symmetrical components , 1977, IEEE Transactions on Power Apparatus and Systems.

[9]  M. S. Sachdev,et al.  A recursive least error squares algorithm for power system relaying and measurement applications , 1991 .

[10]  B. J. Mann,et al.  Relaying a Three Phase Transmission Line with a Digital Computer , 1971 .

[11]  I. F. Morrison,et al.  Digital Calculation of Impedance for Transmission Line Protection , 1971 .

[12]  D. L. Waikar,et al.  Symmetrical component based improved fault impedance estimation method for digital distance protection Part I. Design aspects , 1993 .

[13]  Y. G. Paithankar Fast(1-shift) orthogonal functions for extraction of the fundamental frequency component for computer relaying , 1988 .

[14]  A. G. Phadke,et al.  A Microcomputer Based Symmetrical Component Distance Relay , 1979 .

[15]  V.Cook Analysis of Distance Protection , 2021, Power System Protection.

[16]  G. D. Rockefeller,et al.  Fault Protection with a Digital Computer , 1969 .

[17]  M.S. Sachdev,et al.  A New Algorithm for Digital Impedance Relays , 1979, IEEE Transactions on Power Apparatus and Systems.

[18]  Adly Girgis,et al.  Application of Kalman Filtering in Computer Relaying , 1981, IEEE Transactions on Power Apparatus and Systems.