Synthetic aperture-based linear-array photoacoustic tomography considering the aperture orientation effect

The synthetic aperture-based linear-array photoacoustic tomography (PAT) was proposed to address the limited-view shortcomings of the single aperture, but the detection field of view (FOV) determined by the aperture orientation effect was not fully considered yet, leading to the limited-view observation and image resolution degradation. Herein, the aperture orientation effect was proposed from the theoretical model and then it was verified via both the numerical simulation and phantom experiment. Different orientations were enumerated sequentially in the simulation to approximate the ideal full-view case for the optimal detection FOV, considering the detection pattern of the linear-array transducer. As a result, the corresponding optimal aperture orientation was 60[Formula: see text] if the synthetic aperture was seamlessly established by three single linear arrays, where the overlapped detection pattern was optimized from the individual linear-array transducer at the adjacent positions. Therefore, the limited-view artifacts were minimized and the image resolution was enhanced in this aperture orientation. This study showed that the aperture orientation had great influence on the optimal detection FOV in the synthetic aperture configuration, where the full-view imaging quality and enhanced image resolution could be achieved.

[1]  Kang Kim,et al.  Multi-Focus Beamforming for Thermal Strain Imaging Using a Single Ultrasound Linear Array Transducer. , 2017, Ultrasound in medicine & biology.

[2]  Yi Shen,et al.  Compressed sensing in synthetic aperture photoacoustic tomography based on a linear-array ultrasound transducer , 2017 .

[3]  Da Xing,et al.  Fast multielement phase-controlled photoacoustic imaging based on limited-field-filtered back-projection algorithm , 2005 .

[4]  Emad M. Boctor,et al.  Synthetic aperture ultrasound imaging with robotic aperture extension , 2015 .

[5]  Sidan Du,et al.  Full-view photoacoustic tomography using asymmetric distributed sensors optimized with compressed sensing method , 2015, Biomed. Signal Process. Control..

[6]  Changhui Li,et al.  Optical fluence compensation for handheld photoacoustic probe: An in vivo human study case , 2017 .

[7]  Robert A Kruger,et al.  Thermoacoustic computed tomography using a conventional linear transducer array. , 2003, Medical physics.

[8]  Lihong V. Wang,et al.  Photoacoustic tomography: principles and advances. , 2016, Electromagnetic waves.

[9]  B T Cox,et al.  k-Wave: MATLAB toolbox for the simulation and reconstruction of photoacoustic wave fields. , 2010, Journal of biomedical optics.

[10]  Guo Li,et al.  Multiview Hilbert transformation for full-view photoacoustic computed tomography using a linear array , 2015, Journal of biomedical optics.

[11]  Yi Shen,et al.  Monte Carlo light transport-based blood vessel quantification using linear array photoacoustic tomography , 2017 .

[12]  Lihong V. Wang,et al.  A practical guide to photoacoustic tomography in the life sciences , 2016, Nature Methods.

[13]  Daniel Razansky,et al.  Optoacoustic Imaging and Tomography: Reconstruction Approaches and Outstanding Challenges in Image Performance and Quantification , 2013, Sensors.

[14]  Lihong V. Wang,et al.  High-numerical-aperture-based virtual point detectors for photoacoustic tomography. , 2008, Applied physics letters.

[15]  Minghua Xu,et al.  Analytic explanation of spatial resolution related to bandwidth and detector aperture size in thermoacoustic or photoacoustic reconstruction. , 2003, Physical review. E, Statistical, nonlinear, and soft matter physics.

[16]  Pai-Chi Li,et al.  All-optical scanhead for ultrasound and photoacoustic dual-modality imaging. , 2012, Optics express.

[17]  Vasilis Ntziachristos,et al.  Three-dimensional optoacoustic tomography using a conventional ultrasound linear detector array: whole-body tomographic system for small animals. , 2013, Medical physics.

[18]  Jeffrey J. L. Carson,et al.  Measurement of photoacoustic transducer position by robotic source placement and nonlinear parameter estimation , 2008, SPIE BiOS.

[19]  D. Xing,et al.  Toward in vivo biopsy of melanoma based on photoacoustic and ultrasound dual imaging with an integrated detector. , 2016, Biomedical optics express.

[20]  Paul C. Beard,et al.  Photoacoustic tomography with a limited-aperture planar sensor and a reverberant cavity , 2007 .

[21]  Jie Tian,et al.  Limited-view photoacoustic imaging based on an iterative adaptive weighted filtered backprojection approach. , 2013, Applied optics.

[22]  Robert Ellwood,et al.  Photoacoustic imaging using acoustic reflectors to enhance planar arrays , 2014, Journal of biomedical optics.

[23]  Minghua Xu,et al.  Pulsed-microwave-induced thermoacoustic tomography: filtered backprojection in a circular measurement configuration. , 2002, Medical physics.

[24]  S. Arridge,et al.  Quantitative spectroscopic photoacoustic imaging: a review. , 2012, Journal of biomedical optics.

[25]  Marc Fournelle,et al.  Analytical calibration of linear transducer arrays for photoacoustic tomography , 2015, European Conference on Biomedical Optics.

[26]  Lihong V. Wang,et al.  Universal back-projection algorithm for photoacoustic computed tomography. , 2005 .

[27]  Lihong V. Wang Multiscale photoacoustic microscopy and computed tomography. , 2009, Nature photonics.

[28]  Ali Mahloojifar,et al.  Double-Stage Delay Multiply and Sum Beamforming Algorithm: Application to Linear-Array Photoacoustic Imaging , 2018, IEEE Transactions on Biomedical Engineering.

[29]  Konstantin Maslov,et al.  Improving limited-view photoacoustic tomography with an acoustic reflector , 2013, Journal of biomedical optics.

[30]  Da Xing,et al.  Fast full-view photoacoustic imaging by combined scanning with a linear transducer array. , 2007, Optics express.

[31]  Lihong V. Wang,et al.  Reconstructions in limited-view thermoacoustic tomography. , 2004, Medical physics.