Estimation of Shear Stress-related Blood Damage in Heart Valve Prostheses - in Vitro Comparison of 25 Aortic Valves

The hemodynamics of heart valve prostheses can be reproducibly investigated in vitro within circulatory mock loops. By measuring the downstream velocity and shear stress fields the shear stresses which are clinically responsible for damage to platelets and red blood cells can be determined. The mechanisms of damage and the effects of shear stresses on blood corpuscles were investigated by Wurzinger et al. (3, 4) at the Aerodynamics Institute of the RWTH Aachen. In the present study, the above data are incorporated into a mathematical correlation, which serves as a basic model for the estimation of blood damage. This mathematical model was applied to in vitro investigations of 25 different aortic valve prostheses. The results were compared to clinical findings. In most cases agreement was good, indicating that this model may be directly applied to the clinical situation. This new method facilitates the estimation of clinically expected blood damage from in vitro measurements. It may be useful for the development and evaluation of new valve prostheses. By comparative evaluation of different valve types it also provides additional information to help the implanting surgeon select the optimum valve for his patient.

[1]  W G Tiederman,et al.  Two-component laser velocimeter measurements downstream of heart valve prostheses in pulsatile flow. , 1986, Journal of biomechanical engineering.

[2]  H Nygaard,et al.  Turbulent stress measurements downstream of six mechanical aortic valves in a pulsatile flow model. , 1988, Journal of biomechanics.

[3]  R. Körfer,et al.  [Effect of valve type and valve function on chronic intravascular hemolysis after alloprosthetic mitral and aortic valve replacement]. , 1983, Zeitschrift fur Kardiologie.

[4]  R. Opitz,et al.  A Couette viscometer for short time shearing of blood. , 1980, Biorheology.

[5]  T. Mueller,et al.  On the hemolytic and thrombogenic potential of occluder prosthetic heart valves from in-vitro measurements. , 1981, Journal of biomechanical engineering.

[6]  H N Sabbah,et al.  Turbulent stresses in the region of aortic and pulmonary valves. , 1982, Journal of biomechanical engineering.

[7]  H Reul,et al.  Velocity and Shear Stress Distribution Downstream of Mechanical Heart Valves in Pulsatile Flow , 1989, The International journal of artificial organs.

[8]  Woo Yr,et al.  In vitro pulsatile flow velocity and turbulent shear stress measurements in the vicinity of mechanical aortic heart valve prostheses. , 1985 .

[9]  H Reul,et al.  In-vitro wall shear measurements at aortic valve prostheses. , 1984, Journal of biomechanics.

[10]  A. Snyder,et al.  Pulsatile prosthetic valve flows. , 1980, Transactions - American Society for Artificial Internal Organs.

[11]  L. J. Wurzinger,et al.  Mechanical bloodtrauma. An overview , 1986 .

[12]  H Schmid-Schönbein,et al.  Platelet and Coagulation Parameters Following Millisecond Exposure to Laminar Shear Stress , 1985, Thrombosis and Haemostasis.