Complex artifact suppression using vestigial sideband filter in Fourier-domain optical coherence tomography.

In order to achieve computationally efficient mirror image rejection during the off-pivot, full-range approach in spectral-domain optical coherence tomography, we used a vestigial sideband (VSB) filter in place of a Hilbert transform. The appropriate choice of the VSB filter parameters enabled almost complete removal of one sideband with much reduced computational load. To determine the optimal filter parameters, we acquired images of the infrared card and analyzed the mirror suppression ratio of the card surface. Comparison between images obtained using the two filters revealed that the computational load is reduced by 52.4±0.17% when using the VSB filter as it requires a much shorter truncation length. Finally, we present the anterior segment images of a human volunteer's eye processed using the VSB filter.

[1]  Changhuei Yang,et al.  Instantaneous quadrature low coherence interferometry with 3 x 3 fiber optic couplers , 2003, Conference on Lasers and Electro-Optics, 2003. CLEO '03..

[2]  Hyun-Woo Jeong,et al.  Optimization for Axial Resolution, Depth Range, and Sensitivity of Spectral Domain Optical Coherence Tomography at 1.3 µm. , 2009, The journal of the Korean Physical Society.

[3]  A. Fercher,et al.  Phase-shifting algorithm to achieve high-speed long-depth-range probing by frequency-domain optical coherence tomography. , 2003, Optics letters.

[4]  T. Yatagai,et al.  Simultaneous B-M-mode scanning method for real-time full-range Fourier domain optical coherence tomography. , 2006, Applied Optics.

[5]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[6]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[7]  Ruikang K. Wang In vivo full range complex Fourier domain optical coherence tomography , 2007 .

[8]  A. Fercher,et al.  Full range complex spectral optical coherence tomography technique in eye imaging. , 2002, Optics letters.

[9]  R. Leitgeb,et al.  High speed full range complex spectral domain optical coherence tomography. , 2005, Optics express.

[10]  Kevin Hsu,et al.  Dual detection full range frequency domain optical coherence tomography. , 2010, Optics letters.

[11]  Michael Pircher,et al.  Full range complex spectral domain optical coherence tomography without additional phase shifters. , 2007, Optics express.

[12]  Changhuei Yang,et al.  Sensitivity advantage of swept source and Fourier domain optical coherence tomography. , 2003, Optics express.

[13]  Chiung-Ting Wu,et al.  Method for suppressing the mirror image in Fourier-domain optical coherence tomography. , 2011, Optics letters.