Monitoring in vivo absorption of a drug-eluting bioabsorbable stent with intravascular ultrasound-derived parameters a feasibility study.

OBJECTIVES The aim of this study was to investigate the feasibility of using quantitative differential echogenicity to monitor the in vivo absorption process of a drug-eluting poly-l-lactic-acid (PLLA) bioabsorbable stent (BVS, Abbott Vascular, Santa Clara, California). BACKGROUND A new bioabsorbable, balloon-expanded coronary stent was recently evaluated in a first-in-man study. Little is known about the absorption process in vivo in diseased human coronary arteries. METHODS In the ABSORB (Clinical Evaluation of the BVS everolimus eluting stent system) study, 30 patients underwent treatment with the BVS coronary stent system and were examined with intracoronary ultrasound (ICUS) after implantation, at 6 months and at 2-year follow-up. Quantitative ICUS was used to measure dimensional changes, and automated ICUS-based tissue composition software (differential echogenicity) was used to quantify plaque compositional changes over time in the treated regions. RESULTS The BVS struts appeared as bright hyperechogenic structures and showed a continuous decrease of their echogenicity over time, most likely due to the polymer degradation process. In 12 patients in whom pre-implantation ICUS was available, at 2 years the percentage-hyperechogenic tissue was close to pre-implantation values, indicating that the absorption process was either completed or the remaining material was no longer differentially echogenic from surrounding tissues. CONCLUSIONS Quantitative differential echogenicity is a useful plaque compositional measurement tool. Furthermore, it seems to be valuable for monitoring the absorption process of bioabsorbable coronary stents made of semi-crystalline polymers.

[1]  William Wijns,et al.  A Cause for Concern , 2007 .

[2]  Patrick W Serruys,et al.  Coronary-artery stents. , 2006, The New England journal of medicine.

[3]  F. Shen,et al.  Monitoring the degradation process of biopolymers by ultrasonic longitudinal wave pulse-echo technique. , 2003, Biomaterials.

[4]  C von Birgelen,et al.  Electrocardiogram-gated intravascular ultrasound image acquisition after coronary stent deployment facilitates on-line three-dimensional reconstruction and automated lumen quantification. , 1997, Journal of the American College of Cardiology.

[5]  W Rutsch,et al.  A comparison of balloon-expandable-stent implantation with balloon angioplasty in patients with coronary artery disease. Benestent Study Group. , 1994, The New England journal of medicine.

[6]  P. Serruys,et al.  Drug-eluting stents show delayed healing: paclitaxel more pronounced than sirolimus. , 2007, European heart journal.

[7]  Benno J. Rensing,et al.  Sustained Suppression of Neointimal Proliferation by Sirolimus-Eluting Stents: One-Year Angiographic and Intravascular Ultrasound Follow-Up , 2001, Circulation.

[8]  Patrick W Serruys,et al.  Evaluation of four-year coronary artery response after sirolimus-eluting stent implantation using serial quantitative intravascular ultrasound and computer-assisted grayscale value analysis for plaque composition in event-free patients. , 2005, Journal of the American College of Cardiology.

[9]  P. Serruys,et al.  Assessment of the absorption process following bioabsorbable everolimus-eluting stent implantation: temporal changes in strain values and tissue composition using intravascular ultrasound radiofrequency data analysis. A substudy of the ABSORB clinical trial. , 2009, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[10]  Friedberg Ck Computers in cardiology. , 1970 .

[11]  C von Birgelen,et al.  ECG-gated versus nongated three-dimensional intracoronary ultrasound analysis: implications for volumetric measurements. , 1998, Catheterization and cardiovascular diagnosis.

[12]  E. Tuzcu,et al.  Coronary Plaque Classification With Intravascular Ultrasound Radiofrequency Data Analysis , 2002, Circulation.

[13]  Patrick W Serruys,et al.  A bioabsorbable everolimus-eluting coronary stent system (ABSORB): 2-year outcomes and results from multiple imaging methods , 2009, The Lancet.

[14]  Patrick W Serruys,et al.  Retrospective image‐based gating of intracoronary ultrasound images for improved quantitative analysis: The intelligate method , 2004, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[15]  H. Uehata,et al.  Initial and 6-month results of biodegradable poly-l-lactic acid coronary stents in humans. , 2000, Circulation.

[16]  Patrick W Serruys,et al.  A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial , 2008, The Lancet.

[17]  Raimund Erbel,et al.  Temporary scaffolding of coronary arteries with bioabsorbable magnesium stents: a prospective, non-randomised multicentre trial , 2007, The Lancet.

[18]  Pertti Törmälä,et al.  Mechanical properties and in vitro degradation of bioabsorbable self-expanding braided stents , 2003, Journal of biomaterials science. Polymer edition.

[19]  Ron Waksman,et al.  Biodegradable stents: they do their job and disappear. , 2006, The Journal of invasive cardiology.

[20]  P. Serruys,et al.  Quantitative multi-modality imaging analysis of a bioabsorbable poly-L-lactic acid stent design in the acute phase: a comparison between 2- and 3D-QCA, QCU and QMSCT-CA. , 2008, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[21]  P. Serruys,et al.  Three‐dimensional and quantitative analysis of atherosclerotic plaque composition by automated differential echogenicity , 2007, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.