Principles and applications of comprehensive two-dimensional gas chromatography

Abstract This issue of Trends in Analytical Chemistry celebrates 50 years of gas chromatography (GC) — the greatest enabling technology for chemical analysis of volatile compounds. However, what may be considered the most powerful separation tool in GC — comprehensive two-dimensional gas chromatography (GC×GC) — is a development born of the 1990s. It was first described and almost fully established in the last decade of the twentieth century. The coming decades can be expected to see it flourish into a major operating mode of GC, when applications and fundamental principles will be further expanded, and, most importantly, its universal acceptance will be unquestioned. This article describes why the pioneers of GC×GC have so much faith in the new opportunities afforded by this exciting technology.

[1]  P. Marriott,et al.  Longitudinally modulated cryogenic system. A generally applicable approach to solute trapping and mobilization in gas chromatography. , 1997, Analytical chemistry.

[2]  Andrew L. Lee,et al.  A Model of Peak Amplitude Enhancement in Orthogonal Two-Dimensional Gas Chromatography , 2001 .

[3]  John B. Phillips,et al.  Comprehensive Two-Dimensional Gas Chromatography using an On-Column Thermal Modulator Interface , 1991 .

[4]  J. Foley,et al.  Effect of Sampling Rate on Resolution in Comprehensive Two-Dimensional Liquid Chromatography , 1998 .

[5]  P. Marriott,et al.  Shape selectivity: A key factor in comprehensive two-dimensional gas chromatographic analysis of toxic PCBs , 2001 .

[6]  Fraga,et al.  Comprehensive two-dimensional gas chromatography and chemometrics for the high-speed quantitative analysis of aromatic isomers in a jet fuel using the standard addition method and an objective retention time alignment algorithm , 2000, Analytical chemistry.

[7]  Richard B. Gaines,et al.  Separation and identification of petroleum biomarkers by comprehensive two-dimensional gas chromatography , 2001 .

[8]  Richard B. Gaines,et al.  Analysis of water samples for trace levels of oxygenate and aromatic compounds using headspace solid-phase microextraction and comprehensive two-dimensional gas chromatography †‡ , 1998 .

[9]  Bruce R. Kowalski,et al.  Second-order chemometric standardization for high-speed hyphenated gas chromatography: Analysis of GC/MS and comprehensive GCGC data , 1999 .

[10]  Andrew L. Lee,et al.  A comparison of modulating interface technologies in comprehensive two‐dimensional gas chromatography (GC×GC) , 2000 .

[11]  P. Marriott,et al.  Concepts and Preliminary Observations on the Triple-Dimensional Analysis of Complex Volatile Samples by Using GC×GC−TOFMS , 2001 .

[12]  P. Marriott,et al.  High resolution essential oil analysis by using comprehensive gas chromatographic methodology , 2000 .

[13]  Andrew L. Lee,et al.  A larger pool of ozone-forming carbon compounds in urban atmospheres , 2000, Nature.

[14]  J. Seeley,et al.  Comprehensive two-dimensional gas chromatography via differential flow modulation , 2000, Analytical chemistry.

[15]  Glenn S. Frysinger,et al.  Oil Spill Source Identification by Comprehensive Two-Dimensional Gas Chromatography , 1999 .

[16]  Robert E. Synovec,et al.  Comprehensive Two-Dimensional High-Speed Gas Chromatography with Chemometric Analysis , 1998 .

[17]  L. Needham,et al.  Comprehensive two-dimensional gas chromatography for the fast separation and determination of pesticides extracted from human serum. , 1994, Analytical chemistry.

[18]  Richard B. Gaines,et al.  Identification of a novel alkenone in Black Sea sediments , 2001 .