Application of statistical design for the optimization of amino acid separation by reverse-phase HPLC.

Modified resolution and overall separation factors used to quantify the separation of complex chromatography systems are described. These factors were proven to be applicable to the optimization of amino acid resolution in reverse-phase (RP) HPLC chromatograms. To optimize precolumn derivatization with phenylisothiocyanate, a 2(5-1) fractional factorial design in triplicate was employed. The five independent variables for optimizing the overall separation factor were triethylamine content of the aqueous buffer, pH of the aqueous buffer, separation temperature, methanol/acetonitrile concentration ratio in the organic eluant, and mobile phase flow rate. Of these, triethylamine concentration and methanol/acetonitrile concentration ratio were the most important. The methodology captured the interaction between variables. Temperature appeared in the interaction terms; consequently, it was included in the hierarchic model. The preliminary model based on the factorial experiments was not able to explain the response curvature in the design space; therefore, a central composite design was used to provide a quadratic model. Constrained nonlinear programming was used for optimization purposes. The quadratic model predicted the optimal levels of the variables. In this study, the best levels of the five independent variables that provide the maximum modified resolution for each pair of consecutive amino acids appearing in the chromatograph were determined. These results are of utmost importance for accurate analysis of a subset of amino acids.

[1]  L. Cynober,et al.  Amino acid determination in biological fluids by automated ion-exchange chromatography: performance of Hitachi L-8500A. , 1997, Clinical chemistry.

[2]  A. Malenović,et al.  Experimental design in reversed-phase high-performance liquid chromatographic analysis of imatinib mesylate and its impurity. , 2004, Journal of chromatography. A.

[3]  B. Bidlingmeyer,et al.  Rapid analysis of amino acids using pre-column derivatization. , 1984, Journal of chromatography.

[4]  S. Cohen Amino acid analysis using precolumn derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate. , 2000, Methods in molecular biology.

[5]  K. Yaegaki,et al.  Improved high-performance liquid chromatography method for quantitation of proline and hydroxyproline in biological materials. , 1986, Journal of chromatography.

[6]  Joel K.Swadesh,et al.  HPLC: Practical and Industrial Applications , 1997 .

[7]  N. Ferreirós,et al.  Optimization via experimental design of an SPE-HPLC-UV-fluorescence method for the determination of valsartan and its metabolite in human plasma samples. , 2006, Journal of separation science.

[8]  J. Peixoto A Property of Well-Formulated Polynomial Regression Models , 1990 .

[9]  S. Udenfriend,et al.  A picomole protein and peptide chemistry: some applications to the opioid peptides. , 1984, Analytical biochemistry.

[10]  K. Wilson,et al.  Amino Acid analyses by high-performance liquid chromatography , 1982 .

[11]  M. Rodrigues,et al.  Response surface analysis and simulation as a tool for bioprocess design and optimization , 2000 .

[12]  B. Bowerman Statistical Design and Analysis of Experiments, with Applications to Engineering and Science , 1989 .

[13]  R. Ebert Amino acid analysis by HPLC: optimized conditions for chromatography of phenylthiocarbamyl derivatives. , 1986, Analytical biochemistry.

[14]  Paul Charles. Sadek,et al.  The HPLC Solvent Guide , 1996 .

[15]  P. Gunasekaran,et al.  Optimization of a fermentation medium for the production of Penicillin G acylase from Bacillus sp. , 2002, Letters in applied microbiology.

[16]  D. S. Lee,et al.  Capillary gas chromatographic determination of proteins and biological amino acids as N(O)-tert.-butyldimethylsilyl derivatives. , 1995, Journal of chromatography. B, Biomedical applications.

[17]  M. Moo-young,et al.  Medium optimization for hen egg white lysozyme production by recombinant Aspergillus niger using statistical methods. , 2005, Biotechnology and bioengineering.

[18]  Stavros Kromidas HPLC Made to Measure , 2006 .

[19]  van Ma Marion Straten,et al.  Effect of buffers on silica-based column stability in reversed-phase high-performance liquid chromatography , 1996 .

[20]  A. Alegría,et al.  Application of the 6-aminoquinolyl-N-hydroxysccinimidyl carbamate (AQC) reagent to the RP-HPLC determination of amino acids in infant foods. , 2006, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[21]  Margaret J. Robertson,et al.  Design and Analysis of Experiments , 2006, Handbook of statistics.

[22]  M. Gennaro,et al.  Simultaneous reversed-phase high-performance liquid chromatographic separation of mono-, di-and trichloroanilines through a gradient elution optimised by experimental design. , 2002, Journal of chromatography. A.

[23]  M. Hariharan,et al.  Systematic approach to the development of plasma amino acid analysis by high-performance liquid chromatography with ultraviolet detection with precolumn derivatization using phenyl isothiocyanate. , 1993, Journal of chromatography.

[24]  M. Roth,et al.  Column chromatography of amino acids with fluorescence detection. , 1973, Journal of chromatography.

[25]  K. Woo,et al.  Determination of protein amino acids as butylthiocarbamyl derivatives by reversed-phase high-performance liquid chromatography with precolumn derivatization and UV detection , 1994 .

[26]  Joel Waldfogel,et al.  Introduction , 2010, Inf. Econ. Policy.

[27]  K. Woo,et al.  Determination of amino acids in the foods by reversed-phase high-performance liquid chromatography with a new precolumn derivative, butylthiocarbamyl amino acid, compared to the conventional phenylthiocarbamyl derivatives and ion-exchange chromatography. , 1996, Journal of chromatography. A.

[28]  J. Nelder The Selection of Terms in Response-Surface Models—How Strong is the Weak-Heredity Principle? , 1998 .

[29]  S. Cohen Analysis of amino acids by liquid chromatography after pre-column derivatization with 4-nitrophenylisothiocyanate , 1990 .

[30]  P. Haynes,et al.  Amino acid analysis using derivatisation with 9-fluorenylmethyl chloroformate and reversed-phase high-performance liquid chromatography. , 1991, Journal of chromatography.

[31]  Douglas C. Montgomery,et al.  Response Surface Methodology: Process and Product Optimization Using Designed Experiments , 1995 .

[32]  G. Box,et al.  On the Experimental Attainment of Optimum Conditions , 1951 .

[33]  R. Early,et al.  High-performance liquid chromatographic separation of phenylthiocarbamyl derivatives of amino acids from protein hydrolysates using a Partisphere C18 column , 1993 .

[34]  P. Cutroneo,et al.  Optimization of a LC method for the enantioseparation of a non-competitive glutamate receptor antagonist, by experimental design methodology. , 2006, Journal of pharmaceutical and biomedical analysis.

[35]  Nicolle H. Packer,et al.  Amino acid analysis protocols , 2000 .

[36]  Derek J. Pike,et al.  Empirical Model‐building and Response Surfaces. , 1988 .

[37]  E. L. Harris Amino Acid analysis by precolumn derivatization. , 1988, Methods in molecular biology.

[38]  D. J. Strydom,et al.  Amino acid analysis utilizing phenylisothiocyanate derivatives. , 1988, Analytical biochemistry.