Geometric calibration of a stationary digital breast tomosynthesis system based on distributed carbon nanotube X-ray source arrays

Stationary digital breast tomosynthesis (sDBT) with distributed X-ray sources based on carbon nanotube (CNT) field emission cathodes has been recently proposed as an approach that can prevent motion blur produced by traditional DBT systems. In this paper, we simulate a geometric calibration method based on a proposed multi-source CNT X-ray sDBT system. This method is a projection matrix-based approach with seven geometric parameters, all of which can be obtained from only one projection datum of the phantom. To our knowledge, this study reports the first application of this approach in a CNT-based multi-beam X-ray sDBT system. The simulation results showed that the extracted geometric parameters from the calculated projection matrix are extremely close to the input values and that the proposed method is effective and reliable for a square sDBT system. In addition, a traditional cone-beam computed tomography (CT) system was also simulated, and the uncalibrated and calibrated geometric parameters were used in image reconstruction based on the filtered back-projection (FBP) method. The results indicated that the images reconstructed with calibrated geometric parameters have fewer artifacts and are closer to the reference image. All the simulation tests showed that this geometric calibration method is optimized for sDBT systems but can also be applied to other application-specific CT imaging systems.

[1]  D. Kopans,et al.  Digital tomosynthesis in breast imaging. , 1997, Radiology.

[2]  Normand Robert,et al.  The geometric calibration of cone-beam systems with arbitrary geometry. , 2009, Physics in medicine and biology.

[3]  David S. Lalush,et al.  EVALUATION OF HEXAGONAL AND SQUARE GEOMETRIES FOR MOTION-FREE ARRAYED-SOURCE X-RAY MICRO-CT , 2007, 2007 4th IEEE International Symposium on Biomedical Imaging: From Nano to Macro.

[4]  Andrei V. Bronnikov,et al.  Virtual alignment of x-ray cone-beam tomography system using two calibration aperture measurements , 1999 .

[5]  Sylvie Sevestre,et al.  Registration-Based Geometric Calibration of Industrial X-ray Tomography System , 2013, IEEE Transactions on Nuclear Science.

[6]  Xinhua Li,et al.  A generic geometric calibration method for tomographic imaging systems with flat-panel detectors--a detailed implementation guide. , 2010, Medical physics.

[7]  Y. Trousset,et al.  Geometrical calibration of X-ray imaging chains for three-dimensional reconstruction. , 1993, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[8]  Dan Xia,et al.  Geometric Calibration of a Micro-CT System and Performance for Insect Imaging , 2011, IEEE Transactions on Information Technology in Biomedicine.

[9]  Ying Hou,et al.  A calibration method for misaligned scanner geometry in cone-beam computed tomography , 2006 .

[10]  David A Jaffray,et al.  Accurate technique for complete geometric calibration of cone-beam computed tomography systems. , 2005, Medical physics.

[11]  Liang Li,et al.  A review of geometric calibration for different 3-D X-ray imaging systems , 2016 .

[12]  Wolfgang Wein,et al.  Geometric calibration using bundle adjustment for cone-beam computed tomography devices , 2012, Medical Imaging.

[13]  C. H. Organ Diagnosis of Diseases of the Breast , 1999 .

[14]  A Del Guerra,et al.  An optimization-based method for geometrical calibration in cone-beam CT without dedicated phantoms. , 2008, Physics in medicine and biology.

[15]  R Clackdoyle,et al.  Analytic method based on identification of ellipse parameters for scanner calibration in cone-beam tomography. , 2000, Physics in medicine and biology.

[16]  Benjamin M. W. Tsui,et al.  Estimation of geometrical parameters for fan beam tomography , 1987 .

[17]  Elizabeth A Rafferty,et al.  Digital mammography: novel applications. , 2007, Radiologic clinics of North America.

[18]  Tuyen Phan,et al.  Design and characterization of a spatially distributed multibeam field emission x-ray source for stationary digital breast tomosynthesis. , 2009, Medical physics.

[19]  Gisella Gennaro,et al.  Digital breast tomosynthesis versus digital mammography: a clinical performance study , 2010, European Radiology.

[20]  C. Meessen,et al.  A geometrical calibration method for the PIXSCAN micro-CT scanner , 2009 .

[21]  Dandan Zheng,et al.  Estimation of CT cone-beam geometry using a novel method insensitive to phantom fabrication inaccuracy: implications for isocenter localization accuracy. , 2011, Medical physics.

[22]  Xiaoquan Yang,et al.  Online Geometric Calibration of Cone-Beam Computed Tomography for Arbitrary Imaging Objects , 2013, IEEE Transactions on Medical Imaging.

[23]  Kai Yang,et al.  A geometric calibration method for cone beam CT systems. , 2006, Medical physics.

[24]  G T Gullberg,et al.  Estimation of geometrical parameters and collimator evaluation for cone beam tomography. , 1990, Medical physics.

[25]  Guang Yang,et al.  Stationary digital breast tomosynthesis system with a multi-beam field emission x-ray source array , 2008, SPIE Medical Imaging.

[26]  Willi A Kalender,et al.  Geometric misalignment and calibration in cone-beam tomography. , 2004, Medical physics.

[27]  Julia F. Barrett,et al.  Artifacts in CT: recognition and avoidance. , 2004, Radiographics : a review publication of the Radiological Society of North America, Inc.