This paper presents the results of an experimental study of forced convection heat transfer in a narrow rectangular duct fitted with a circular tube and/or a delta-winglet pair. The duct was designed to simulate a single passage in a fin-tube heat exchanger. Heat transfer measurements were obtained using a transient technique in which a heated airflow is suddenly introduced to the test section. High-resolution local fin-surface temperature distributions were obtained at several times after initiation of the transient using an imaging infrared camera. Corresponding local fin-surface heat transfer coefficient distributions were then calculated from a locally applied one-dimensional semi-infinite inverse heat conduction model. Heat transfer results were obtained over an airflow rate ranging from 1.51 x 10-3 to 14.0 x 10-3 kg/s. These flow rates correspond to a duct-height Reynolds number range of 670 – 6300 with a duct height of 1.106 cm and a duct width-toheight ratio, W/H, of 11.25. The test cylinder was sized such that the diameter-to-duct height ratio, D/H is 5. Results presented in this paper reveal visual and quantitative details of local fin-surface heat transfer distributions in the vicinity of a circular tube, a delta-winglet pair, and a combination of a circular tube and amore » delta-winglet pair. Comparisons of local and average heat transfer distributions for the circular tube with and without winglets are provided. Overall mean finsurface Nusselt-number results indicate a significant level of heat transfer enhancement associated with the deployment of the winglets with the circular cylinder. At the lowest Reynolds numbers (which correspond to the laminar operating conditions of existing geothermal air-cooled condensers), the enhancement level is nearly a factor of two. At higher Reynolds numbers, the enhancement level is close to 50%.« less
[1]
R. J. Moffat,et al.
Contributions to the Theory of Single-Sample Uncertainty Analysis
,
1982
.
[2]
Martin Fiebig,et al.
Wing-type vortex generators for fin-and-tube heat exchangers
,
1993
.
[3]
M. Fiebig,et al.
Experimental investigations of heat transfer enhancement and flow losses in a channel with double rows of longitudinal vortex generators
,
1993
.
[4]
K. Nishino,et al.
Mechanism of Heat Transfer Augmentation by Longitudinal Vortices in a Flat Plate Boundary Layer
,
1994
.
[5]
R. Shah,et al.
Heat transfer surface enhancement through the use of longitudinal vortices: a review of recent progress
,
1995
.
[6]
CONJUGATE HEAT TRANSFER OF A FINNED OVAL TUBE PART B: HEAT TRANSFER BEHAVIORS
,
1998
.
[7]
M. Fiebig,et al.
Heat transfer enhancement of a finned oval tube with punched longitudinal vortex generators in-line
,
1998
.