An Implantable Wireless Neural Interface System for Simultaneous Recording and Stimulation of Peripheral Nerve with a Single Cuff Electrode

Recently, implantable devices have become widely used in neural prostheses because they eliminate endemic drawbacks of conventional percutaneous neural interface systems. However, there are still several issues to be considered: low-efficiency wireless power transmission; wireless data communication over restricted operating distance with high power consumption; and limited functionality, working either as a neural signal recorder or as a stimulator. To overcome these issues, we suggest a novel implantable wireless neural interface system for simultaneous neural signal recording and stimulation using a single cuff electrode. By using widely available commercial off-the-shelf (COTS) components, an easily reconfigurable implantable wireless neural interface system was implemented into one compact module. The implantable device includes a wireless power consortium (WPC)-compliant power transmission circuit, a medical implant communication service (MICS)-band-based radio link and a cuff-electrode path controller for simultaneous neural signal recording and stimulation. During in vivo experiments with rabbit models, the implantable device successfully recorded and stimulated the tibial and peroneal nerves while communicating with the external device. The proposed system can be modified for various implantable medical devices, especially such as closed-loop control based implantable neural prostheses requiring neural signal recording and stimulation at the same time.

[1]  D. Hwang,et al.  Feedback control of electrode offset voltage during functional electrical stimulation , 2013, Journal of Neuroscience Methods.

[2]  Yi Su,et al.  A Wireless 32-Channel Implantable Bidirectional Brain Machine Interface , 2016, Sensors.

[3]  R. Bragós,et al.  An implantable bioimpedance monitor using 2.45 GHz band for telemetry , 2013, Physiological Measurement.

[4]  J A Hoffer,et al.  Restoration of use of paralyzed limb muscles using sensory nerve signals for state control of FES-assisted walking. , 1999, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[5]  D B Grayden,et al.  A fully implantable rodent neural stimulator , 2012, Journal of neural engineering.

[6]  D. Guiraud,et al.  An implantable neuroprosthesis for standing and walking in paraplegia: 5-year patient follow-up , 2006, Journal of neural engineering.

[7]  Peter D. Bradley,et al.  Wireless medical implant technology — Recent advances and future developments , 2011, 2011 Proceedings of the ESSCIRC (ESSCIRC).

[8]  Alexander D. Rush,et al.  A Power and Data Link for a Wireless-Implanted Neural Recording System , 2012, IEEE Transactions on Biomedical Engineering.

[9]  Chua-Chin Wang,et al.  An implantable bi-directional wireless transmission system for transcutaneous biological signal recording , 2005, Physiological measurement.

[10]  M. Haugland,et al.  Artifact-free sensory nerve signals obtained from cuff electrodes during functional electrical stimulation of nearby muscles , 1994 .

[11]  Hans Permana,et al.  Developing a Wireless Implantable Body Sensor Network in MICS Band , 2011, IEEE Transactions on Information Technology in Biomedicine.

[12]  R. Stein,et al.  Instrumentation for ENG and EMG recordings in FES systems , 1994, IEEE Transactions on Biomedical Engineering.

[13]  Iasonas F. Triantis,et al.  On cuff imbalance and tripolar ENG amplifier configurations , 2005, IEEE Transactions on Biomedical Engineering.

[14]  Peter J. Kyberd,et al.  MARCUS: a two degree of freedom hand prosthesis with hierarchical grip control , 1995 .

[15]  Soo Hyun Lee,et al.  Fabrication and characterization of implantable and flexible nerve cuff electrodes with Pt, Ir and IrOx films deposited by RF sputtering , 2010 .

[16]  Johannes J. Struijk,et al.  Fascicle-Selectivity of an Intraneural Stimulation Electrode in the Rabbit Sciatic Nerve , 2012, IEEE Transactions on Biomedical Engineering.

[17]  Silvestro Micera,et al.  Neuro-fuzzy extraction of angular information from muscle afferents for ankle control during standing in paraplegic subjects: an animal model , 2001, IEEE Transactions on Biomedical Engineering.

[18]  Ying Yao,et al.  An Implantable 64-Channel Wireless Microsystem for Single-Unit Neural Recording , 2009, IEEE Journal of Solid-State Circuits.

[19]  G M Lyons,et al.  Effect of walking speed changes on tibialis anterior EMG during healthy gait for FES envelope design in drop foot correction. , 2007, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[20]  Dominik Stunder,et al.  Assessment of Electromagnetic Interference with Active Cardiovascular Implantable Electronic Devices (CIEDs) Caused by the Qi A13 Design Wireless Charging Board , 2015, International journal of environmental research and public health.

[21]  Nitish V. Thakor,et al.  Enabling Wireless Powering and Telemetry for Peripheral Nerve Implants , 2015, IEEE Journal of Biomedical and Health Informatics.

[22]  Kamran Entesari,et al.  Design and implementation of a wireless medical system prototype for implantable applications , 2015 .

[23]  P Bertemes-Filho,et al.  A comparison of modified Howland circuits as current generators with current mirror type circuits. , 2000, Physiological measurement.

[24]  T. Sinkjaer,et al.  Implantable telemeter for long-term electroneurographic recordings in animals and humans , 2003, Medical and Biological Engineering and Computing.

[25]  Jian Huang,et al.  A semi-implantable multichannel telemetry system for continuous electrical, mechanical and hemodynamical recordings in animal cardiac research. , 2007, Physiological measurement.

[26]  Ming-Shaung Ju,et al.  Model-based ankle joint angle tracing by cuff electrode recordings of peroneal and tibial nerves , 2007, Medical & Biological Engineering & Computing.

[27]  Paolo Dario,et al.  An implantable ZigBee ready telemetric platform for in vivo monitoring of physiological parameters , 2008 .

[28]  W. Jensen,et al.  Effect of initial joint position on nerve-cuff recordings of muscle afferents in rabbits , 2001, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[29]  Ming Yin,et al.  A 100-Channel Hermetically Sealed Implantable Device for Chronic Wireless Neurosensing Applications , 2013, IEEE Transactions on Biomedical Circuits and Systems.

[30]  Bill Johns,et al.  Designing a Qi-compliant receiver coil for wireless power systems, Part 1 , 2012 .

[31]  Xiaofei Yang,et al.  A digital wireless system for closed-loop inhibition of nociceptive signals , 2012, Journal of neural engineering.

[32]  W. Jensen,et al.  Improving signal reliability for on-line joint angle estimation from nerve cuff recordings of muscle afferents , 2002, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[33]  M. Elhilali,et al.  Implantable selective stimulator to improve bladder voiding: design and chronic experiments in dogs. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[34]  Nitish V. Thakor,et al.  Implantable neurotechnologies: electrical stimulation and applications , 2015, Medical & Biological Engineering & Computing.

[35]  Maurits Ortmanns,et al.  Optical transcutaneous link for low power, high data rate telemetry , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[36]  D. Hwang,et al.  Improvement of signal-to-interference ratio and signal-to-noise ratio in nerve cuff electrode systems , 2012, Physiological measurement.

[37]  Qi Xu,et al.  A fully implanted programmable stimulator based on wireless communication for epidural spinal cord stimulation in rats , 2012, Journal of Neuroscience Methods.

[38]  Qi Author Planar Wireless Charging Technology for Portable Electronic Products and Qi , 2013 .

[39]  Qi Xu,et al.  A Fully Implantable Stimulator With Wireless Power and Data Transmission for Experimental Investigation of Epidural Spinal Cord Stimulation , 2015, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[40]  Patrick D Wolf,et al.  A fully implantable 96-channel neural data acquisition system , 2009, Journal of neural engineering.

[41]  Kenneth Horch,et al.  A charge-balanced pulse generator for nerve stimulation applications , 2008, Journal of Neuroscience Methods.

[42]  Mehmet Rasit Yuce,et al.  Review of Medical Implant Communication System (MICS) band and network , 2016, ICT Express.

[43]  Maysam Ghovanloo,et al.  An Inductively Powered Scalable 32-Channel Wireless Neural Recording System-on-a-Chip for Neuroscience Applications , 2010, IEEE Transactions on Biomedical Circuits and Systems.

[44]  Thomas Sinkjær,et al.  Cutaneous whole nerve recordings used for correction of footdrop in hemiplegic man , 1995 .

[45]  S. Silberstein,et al.  Occipital nerve stimulation for the treatment of intractable chronic migraine headache: ONSTIM feasibility study , 2011, Cephalalgia : an international journal of headache.

[46]  Robert Rieger,et al.  An implanted system for multi-site nerve cuff-based ENG recording using velocity selectivity , 2009 .

[47]  Thermpon Ativanichayaphong,et al.  A combined wireless neural stimulating and recording system for study of pain processing , 2008, Journal of Neuroscience Methods.

[48]  Yoon-Kyu Song,et al.  Wireless, high-bandwidth recordings from non-human primate motor cortex using a scalable 16-Ch implantable microsystem , 2009, 2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[49]  Jan Van der Spiegel,et al.  The PennBMBI: Design of a General Purpose Wireless Brain-Machine-Brain Interface System , 2015, IEEE Transactions on Biomedical Circuits and Systems.

[50]  T Sinkjaer,et al.  Nerve cuff recordings of muscle afferent activity from tibial and peroneal nerves in rabbit during passive ankle motion. , 2000, IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[51]  R C Pinnell,et al.  Miniature wireless recording and stimulation system for rodent behavioural testing , 2015, Journal of neural engineering.

[52]  P H Peckham,et al.  Implanted stimulators for restoration of function in spinal cord injury. , 2001, Medical engineering & physics.

[53]  Chou-Ching K. Lin,et al.  High frequency block of selected axons using an implantable microstimulator , 2004, Journal of Neuroscience Methods.