Characterization of outdoor submicron particles and selected combustion sources of indoor particles

Environmental tobacco smoke, mosquito-coil smoke, and joss stick smoke are the major indoor combustion sources in Asian countries. Field evaluations of the size distributions of outdoor submicron particles and selected combustion sources of indoor particles were conducted in an apartment in Taipei urban area. The size distributions of submicron aerosols were determined by a high resolution particle sizer, which could measure the particles in the size range of 0.017–0.886 μm. The particle sizer contains a differential mobility analyser (TSI 3071) and a condensation particle counter (TSI 3022). The number concentrations of the indoor and outdoor submicron particles varied from 14,000 to 150,000 cm−3 and from 10,000 to 45,000 cm−3, respectively. The changes of the size distributions and the number concentrations of submicron aerosols before, during, and after the aerosol generations were compared. The average number median diameters of environmental tobacco smoke, smoldering cigarettes, mosquito-coil smoke, joss stick smoke, the indoor typical conditions, and the outdoor typical conditions were 0.090, 0.085, 0.094, 0.084, 0.091 and 0.054 μm, respectively. Regarding the surface area-weighted size distributions, the average surface median diameters of these conditions were 0.229, 0.219, 0.282, 0.188, 0.224 and 0.221 μm, respectively. In addition, the average volume median diameters were 0.338, 0.332, 0.398, 0.289, 0.330 and 0.340 μm, respectively. These indoor combustion sources did generate a significant number of the ultrafine and submicron particles which have higher deposition probabilities in the respiratory tract. Further health evaluations of the submicron particles from these combustion sources are needed.

[1]  H. Kesteloot,et al.  Environmental tobacco smoke. Measuring exposures and assessing health effects : by B. Hulka (Ed.) National Academy Press, Washington, D.C., 1986 337 pp. [pound sign]19.20 , 1987 .

[2]  J. D. Wilson,et al.  Dilution of cigarette smoke for real time aerodynamic sizing with a spart analyzer , 1982 .

[3]  David T. Grimsrud,et al.  Control of respirable particles in indoor air with portable air cleaners , 1985 .

[4]  L. K. Peters,et al.  Particle Size Distribution of Mainstream Cigarette Smoke Undergoing Dilution , 1985 .

[5]  R. Schlesinger,et al.  Main Features of the Proposed NCRP Respiratory Tract Model , 1991 .

[6]  W. Liu,et al.  Toxic effects of mosquito coil (a mosquito repellent) smoke on rats. I. Properties of the mosquito coil and its smoke. , 1987, Toxicology letters.

[7]  G. Lazaridis,et al.  Environmental tobacco smoke: comparative characterization by mutagenicity assays of sidestream and mainstream cigarette smoke. , 1986, Environmental mutagenesis.

[9]  B. Ingebrethsen Evolution of the Particle Size Distribution of Mainstream Cigarette Smoke During a Puff , 1986 .

[10]  E. Knutson,et al.  Indoor Radon Progeny Aerosol Size Measurements in Urban, Suburban, and Rural Regions , 1991 .

[11]  W. Liu,et al.  Ultrastructural changes of tracheal epithelium and alveolar macrophages of rats exposed to mosquito coil smoke. , 1988, Toxicology letters.

[12]  W. Nixon,et al.  The Respiratory Tract Deposition Model Proposed by the ICRP Task Group , 1991 .

[13]  H. Savolainen,et al.  Impact of thermal proofing of a church on its indoor air quality : the combustion of candles and incense as a source of pollution , 1991 .

[14]  J. D. Wilson,et al.  Particle size distribution of mainstream tobacco and marijuana smoke. Analysis using the electrical aerosol analyzer. , 1989, The American review of respiratory disease.

[15]  R. Sextro,et al.  Characterization of particle composition, organic vapor constituents, and mutagenicity of indoor air pollutant emissions , 1986 .

[16]  E. Knutson,et al.  Indoor Outdoor Aerosol Measurements for Two Residential Buildings in New Jersey , 1988 .