Influence of intrafraction motion on margins for prostate radiotherapy.

PURPOSE To assess the impact of intrafraction intervention on margins for prostate radiotherapy. METHODS AND MATERIALS Eleven supine prostate patients with three implanted transponders were studied. The relative transponder positions were monitored for 8 min and combined with previously measured data on prostate position relative to skin marks. Margins were determined for situations of (1) skin-based positioning, and (2) pretreatment transponder positioning. Intratreatment intervention was simulated assuming conditions of (1) continuous tracking, and (2) a 3-mm threshold for position correction. RESULTS For skin-based setup without and with inclusion of intrafraction motion, prostate treatments would have required average margins of 8.0, 7.3, and 10.0 mm and 8.2, 10.2, and 12.5 mm, about the left-right, anterior-posterior, and cranial-caudal directions, respectively. Positioning by prostate markers at the start of the treatment fraction reduced these values to 1.8, 5.8, and 7.1 mm, respectively. Interbeam adjustment further reduced margins to an average of 1.4, 2.3, and 1.8 mm. Intrabeam adjustment yielded margins of 1.3, 1.5, and 1.5 mm, respectively. CONCLUSION Significant reductions in margins might be achieved by repositioning the patient before each beam, either radiographically or electromagnetically. However, 2 of the 11 patients would have benefited from continuous target tracking and threshold-based intervention.

[1]  R. Pötter,et al.  The influence of a rectal balloon tube as internal immobilization device on variations of volumes and dose-volume histograms during treatment course of conformal radiotherapy for prostate cancer. , 2002, International journal of radiation oncology, biology, physics.

[2]  K L Lam,et al.  Improvement of precision in spatial localization of radio-opaque markers using the two-film technique. , 1991, Medical physics.

[3]  Gregory C Sharp,et al.  Integrated radiotherapy imaging system (IRIS): design considerations of tumour tracking with linac gantry-mounted diagnostic x-ray systems with flat-panel detectors , 2004, Physics in medicine and biology.

[4]  D P Dearnaley,et al.  Evaluating the effect of rectal distension and rectal movement on prostate gland position using cine MRI. , 1999, International journal of radiation oncology, biology, physics.

[5]  J. Ciezki,et al.  Fluoroscopic study of tumor motion due to breathing: facilitating precise radiation therapy for lung cancer patients. , 2001, Medical physics.

[6]  James M Balter,et al.  Daily targeting of intrahepatic tumors for radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[7]  Hiroki Shirato,et al.  Feasibility of synchronization of real-time tumor-tracking radiotherapy and intensity-modulated radiotherapy from viewpoint of excessive dose from fluoroscopy. , 2004, International journal of radiation oncology, biology, physics.

[8]  Benjamin Movsas,et al.  Measurement of intrafractional prostate motion using magnetic resonance imaging. , 2002, International journal of radiation oncology, biology, physics.

[9]  Jan J W Lagendijk,et al.  Measurements and clinical consequences of prostate motion during a radiotherapy fraction. , 2002, International journal of radiation oncology, biology, physics.

[10]  A Bel,et al.  High-precision prostate cancer irradiation by clinical application of an offline patient setup verification procedure, using portal imaging. , 1996, International journal of radiation oncology, biology, physics.

[11]  R K Ten Haken,et al.  The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[12]  D. Yan,et al.  Adaptive radiation therapy , 1997, Physics in medicine and biology.

[13]  J M Balter,et al.  A comparison of ventilatory prostate movement in four treatment positions. , 2000, International journal of radiation oncology, biology, physics.

[14]  John Wong,et al.  Accuracy of a wireless localization system for radiotherapy. , 2005, International journal of radiation oncology, biology, physics.

[15]  K. Brock,et al.  Determination of ventilatory liver movement via radiographic evaluation of diaphragm position. , 2001, International journal of radiation oncology, biology, physics.

[16]  G T Chen,et al.  Online repositioning during treatment of the prostate: a study of potential limits and gains. , 1993, International journal of radiation oncology, biology, physics.

[17]  E. B. Butler,et al.  Prostate immobilization using a rectal balloon , 2002, Journal of applied clinical medical physics.

[18]  G Morton,et al.  Target position variability throughout prostate radiotherapy. , 1998, International journal of radiation oncology, biology, physics.

[19]  D L McShan,et al.  Automated determination of patient setup errors in radiation therapy using spherical radio-opaque markers. , 1993, Medical physics.

[20]  M. V. van Herk,et al.  The probability of correct target dosage: dose-population histograms for deriving treatment margins in radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[21]  Mark Ruschin,et al.  Digital fluoroscopy to quantify lung tumor motion: potential for patient-specific planning target volumes. , 2003, International journal of radiation oncology, biology, physics.

[22]  R. Miralbell,et al.  Target repositioning optimization in prostate cancer: is intensity-modulated radiotherapy under stereotactic conditions feasible? , 2004, International journal of radiation oncology, biology, physics.

[23]  James M. Balter,et al.  Ventilatory movement of the prostate during radiotherapy , 2000 .

[24]  Shinichi Shimizu,et al.  Three-dimensional intrafractional movement of prostate measured during real-time tumor-tracking radiotherapy in supine and prone treatment positions. , 2002, International journal of radiation oncology, biology, physics.

[25]  E. Yorke,et al.  Respiratory gating for liver tumors: Use in dose escalation , 2003 .

[26]  D Yan,et al.  A new model for "accept or reject" strategies in off-line and on-line megavoltage treatment evaluation. , 1995, International journal of radiation oncology, biology, physics.

[27]  Interventions to reduce organ motion effects in radiation delivery. , 2004, Seminars in radiation oncology.

[28]  B. Heijmen,et al.  A protocol for the reduction of systematic patient setup errors with minimal portal imaging workload. , 2001, International journal of radiation oncology, biology, physics.

[29]  John T. Wei,et al.  Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer. , 2006, International journal of radiation oncology, biology, physics.

[30]  Gikas S. Mageras,et al.  Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system , 2001, Journal of applied clinical medical physics.

[31]  J Wong,et al.  Adaptive modification of treatment planning to minimize the deleterious effects of treatment setup errors. , 1997, International journal of radiation oncology, biology, physics.

[32]  Randall K Ten Haken,et al.  Daily prostate targeting using implanted radiopaque markers. , 2001, International journal of radiation oncology, biology, physics.

[33]  P L Roberson,et al.  Impact of ultrasound and computed tomography prostate volume registration on evaluation of permanent prostate implants. , 1997, International journal of radiation oncology, biology, physics.