A Syringe and Cartridge Method for Down‐Hole Sampling for Trace Organics in Ground Water

A newly developed technique which allows the down-hole sampling and subsequent analysis of ground water for trace organic contaminants was tested during an investigation of contaminant migration at an inactive landfill site in Burlington, Ontario, Canada. The sampling device, which is lowered down piezometers with a tube, consists of a small cylindrical cartridge of sorbent material attached to a syringe. Vacuum or pressure applied at the surface controls the movement of the plunger in the syringe. The volume of the syringe determines the volume of sample water that passes through the cartridge. The cartridge is removed from the syringe at the surface. One cartridge is used for each sampling; the syringe is reusable. The residual water in the cartridge is removed in the laboratory, and the cartridge is desorbed to a fused silica capillary column for analysis by gas chromatography (GC). The analyses discussed here were performed on a GC/mass spectrometer/data system (GC/MS/DS). Of the many organic compounds that were identified in the samples, three compounds were clearly landfill-related: 1,1,1-trichloroethane, chlorobenzene, and para-dichlorobenzene. The three compounds were found at levels substantially above blank levels in 9, 5, and 5 piezometers, respectively. The average concentrations were 14., 5.3, and 0.88μg/1 (ppb), respectively. The pooled coefficients of variation for the analyses for the three compounds were 27., 6.9, and 6.4%, respectively. The volatility of 1,1,1-trichloroethane was probably the cause of the greater variability in its analytical data. The main advantages of the technique over most conventional sampling methods include: (1) down-hole sampling in a manner which minimizes the potential for volatilization losses; (2) avoidance of passage of the sample through long sections of tubing that may contaminate the sample or cause adsorptive losses; (3) convenience of sample handling, storage, and shipping; and (4) high sensitivity.

[1]  John A. Glaser,et al.  Trace analyses for wastewaters , 1981 .

[2]  J. Pankow,et al.  Tenax-GC cartridge for interfacing capillary column gas chromatography with adsorption/thermal desorption for determination of trace organics , 1982 .

[3]  J. Pankow,et al.  Effects of linear flow velocity and residence time on the retention of non-polar aqueous organic analytes by cartridges of tenax-gc , 1982 .

[4]  R. V. Nicholson,et al.  Migration of contaminants in groundwater at a landfill: A case study 6. Hydrogeochemistry , 1983 .

[5]  T. A. Bellar,et al.  Determining volatile organics at microgram-per-litre levels by gas chromatography , 1974 .

[6]  W. Bertsch,et al.  Trace analysis of organic volatiles in water by gas chromatography-mass spectrometry with glass capillary columns. , 1975, Journal of chromatography.

[7]  R. Farvolden,et al.  Migration of contaminants in groundwater at a landfill: A case study: 3. Tritium as an indicator of dispersion and recharge , 1983 .

[8]  W. Asher,et al.  Trace organic compounds in rain. 1. Sampler design and analysis by adsorption/thermal desorption (ATD). , 1984, Environmental science & technology.

[9]  H. Lichtenstein,et al.  Concentration and analysis of trace volatile organics in gases and biological fluids with a new solid adsorbent , 1973 .

[10]  R. Harris,et al.  Migration of contaminants in groundwater at a landfill: A case study: 7. DC, VLF, and inductive resistivity surveys , 1983 .

[11]  Stephen G. Walburn,et al.  Collection and analysis of hazardous organic emissions , 1982 .

[12]  John A. Cherry,et al.  Migration of contaminants in groundwater at a landfill: A case study: 4. A natural-gradient dispersion test , 1983 .

[13]  J. Pankow,et al.  Adsorption-thermal desorption as a method for the determination of low levels of aqueous organics , 1982 .

[14]  John A. Cherry,et al.  Migration of contaminants in groundwater at a landfill: A case study: 1. Groundwater flow and plume delineation , 1983 .

[15]  William A. Telliard,et al.  PRIORITY POLLUTANTS I-A PERSPECTIVES VIEW , 1979 .

[16]  John A. Cherry,et al.  Migration of contaminants in groundwater at a landfill: A case study: 2. Groundwater monitoring devices , 1983 .

[17]  J. Pankow Cold trapping of volatile organic compounds on fused silica capillary columns , 1983 .