Adaptable near-infrared spectroscopy fiber array for improved coupling to different breast sizes during clinical MRI.

RATIONALE AND OBJECTIVES Near-infrared spectroscopy (NIRS) of breast can provide functional information on the vascular and structural compartments of tissues in regions identified during simultaneous magnetic resonance imaging (MRI). NIRS can be acquired during dynamic contrast-enhanced MRI (DCE-MRI) to accomplish image-guided spectroscopy of the enhancing regions, potentially increasing the diagnostic specificity of the examination and reducing the number of biopsies performed as a result of inconclusive MRI breast imaging studies. MATERIALS AND METHODS We combine synergistic attributes of concurrent DCE-MRI and NIRS with a new design of the clinical NIRS breast interface that couples to a standard MR breast coil and allows imaging of variable breast sizes. Spectral information from healthy volunteers and cancer patients is recovered, providing molecular information in regions defined by the segmented MR image volume. RESULTS The new coupling system significantly improves examination utility by allowing improved coupling of the NIR fibers to breasts of all cup sizes and lesion locations. This improvement is demonstrated over a range of breast sizes (cup size A through D) and normal tissue heterogeneity using a group of eight healthy volunteers and two cancer patients. Lesions located in the axillary region and medial-posterior breast are now accessible to NIRS optodes. Reconstructed images were found to have biologically plausible hemoglobin content, oxygen saturation, and water and lipid fractions. CONCLUSIONS In summary, a new NIRS/MRI breast interface was developed to accommodate the variation in breast sizes and lesion locations that can be expected in clinical practice. DCE-MRI-guided NIRS quantifies total hemoglobin, oxygenation, and scattering in MR-enhancing regions, increasing the diagnostic information acquired from MR examinations.

[1]  Bernd Hamm,et al.  Near-infrared laser computed tomography of the breast first clinical experience. , 2008, Academic radiology.

[2]  C. Kuhl Current status of breast MR imaging. Part 2. Clinical applications. , 2007, Radiology.

[3]  M. Schweiger,et al.  Photon-measurement density functions. Part 2: Finite-element-method calculations. , 1995, Applied optics.

[4]  K D Paulsen,et al.  Spectroscopic diffuse optical tomography for the quantitative assessment of hemoglobin concentration and oxygen saturation in breast tissue. , 1999, Applied optics.

[5]  B. Pogue,et al.  Image-guided optical spectroscopy provides molecular-specific information in vivo: MRI-guided spectroscopy of breast cancer hemoglobin, water, and scatterer size. , 2007, Optics letters.

[6]  E. Conant,et al.  Breast Cancer Detection Based on Incremental Biochemical and Physiological Properties of Breast Cancers , 2005 .

[7]  B. Pogue,et al.  Remote positioning optical breast magnetic resonance coil for slice-selection during image-guided near-infrared spectroscopy of breast cancer. , 2011, Journal of biomedical optics.

[8]  Brian W. Pogue,et al.  A generalized least-squares minimization method for near infrared diffuse optical tomography , 2007 .

[9]  David Hsiang,et al.  Characterization of metabolic differences between benign and malignant tumors: high-spectral-resolution diffuse optical spectroscopy. , 2010, Radiology.

[10]  Brian W. Pogue,et al.  Automatic and robust calibration of optical detector arrays for biomedical diffuse optical spectroscopy , 2012, Biomedical optics express.

[11]  Keith D. Paulsen,et al.  Quantifying adipose and fibroglandular breast tissue properties using MRI-guided NIR tomography , 2005, SPIE BiOS.

[12]  B. Pogue,et al.  Imaging breast adipose and fibroglandular tissue molecular signatures by using hybrid MRI-guided near-infrared spectral tomography. , 2006, Proceedings of the National Academy of Sciences of the United States of America.

[13]  S. Arridge Photon-measurement density functions. Part I: Analytical forms. , 1995, Applied optics.

[14]  B. Tromberg,et al.  In vivo absorption, scattering, and physiologic properties of 58 malignant breast tumors determined by broadband diffuse optical spectroscopy. , 2006, Journal of biomedical optics.

[15]  R. Pozzi Mucelli,et al.  Multifocal, multicentric and contralateral breast cancers: breast MR imaging in the preoperative evaluation of patients with newly diagnosed breast cancer , 2011, La radiologia medica.

[16]  David A Boas,et al.  Assessing the future of diffuse optical imaging technologies for breast cancer management. , 2008, Medical physics.

[17]  D. Miglioretti,et al.  Individual and Combined Effects of Age, Breast Density, and Hormone Replacement Therapy Use on the Accuracy of Screening Mammography , 2003, Annals of Internal Medicine.

[18]  L. Tabár,et al.  Effect of Baseline Breast Density on Breast Cancer Incidence, Stage, Mortality, and Screening Parameters: 25-Year Follow-up of a Swedish Mammographic Screening , 2010, Cancer Epidemiology, Biomarkers & Prevention.

[19]  Subhadra Srinivasan,et al.  Methodology development for three-dimensional MR-guided near infrared spectroscopy of breast tumors. , 2008, Optics express.

[20]  N Houssami,et al.  A systematic review of the effectiveness of magnetic resonance imaging (MRI) as an addition to mammography and ultrasound in screening young women at high risk of breast cancer. , 2007, European journal of cancer.

[21]  Soren D. Konecky,et al.  Differentiation of benign and malignant breast tumors by in-vivo three-dimensional parallel-plate diffuse optical tomography. , 2009, Journal of biomedical optics.

[22]  V. Ntziachristos,et al.  Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement. , 2000, Proceedings of the National Academy of Sciences of the United States of America.

[23]  Hamid Dehghani,et al.  Near infrared optical tomography using NIRFAST: Algorithm for numerical model and image reconstruction. , 2009, Communications in numerical methods in engineering.

[24]  A. Paterson,et al.  Mammographic breast density as an intermediate phenotype for breast cancer. , 2005, The Lancet. Oncology.

[25]  Heidrun Wabnitz,et al.  Scanning Time-domain Optical Mammography: Detection and Characterization of Breast Tumors In Vivo , 2005, Technology in cancer research & treatment.

[26]  P. Skaane,et al.  Randomized trial of screen-film versus full-field digital mammography with soft-copy reading in population-based screening program: follow-up and final results of Oslo II study. , 2007, Radiology.

[27]  Brian W. Pogue,et al.  Magnetic resonance-guided near-infrared tomography of the breast , 2004 .

[28]  B. Pogue,et al.  Three-dimensional optical tomography: resolution in small-object imaging. , 2003, Applied optics.

[29]  B. Pogue,et al.  A parallel-detection frequency-domain near-infrared tomography system for hemoglobin imaging of the , 2001 .

[30]  Dirk Grosenick,et al.  Breast cancer: early- and late-fluorescence near-infrared imaging with indocyanine green--a preliminary study. , 2011, Radiology.

[31]  Brian W. Pogue,et al.  Interpreting hemoglobin and water concentration, oxygen saturation, and scattering measured in vivo by near-infrared breast tomography , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[32]  B. Tromberg,et al.  Diffuse optical spectroscopic imaging correlates with final pathological response in breast cancer neoadjuvant chemotherapy , 2011, Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences.

[33]  Jennifer J. Gibson,et al.  In vivo hemoglobin and water concentrations, oxygen saturation, and scattering estimates from near-infrared breast tomography using spectral reconstruction. , 2006, Academic radiology.

[34]  X. Intes Time-domain optical mammography SoftScan: initial results. , 2005, Academic radiology.

[35]  Simon R. Arridge,et al.  Iterative reconstruction of near-infrared absorption images , 1992, Optics & Photonics.

[36]  Britton Chance,et al.  Differentiation of benign and malignant breast lesions by in-vivo three-dimensional diffuse optical tomography. , 2009 .

[37]  M. Schweiger,et al.  Image reconstruction in optical tomography in the presence of coupling errors. , 2007, Applied optics.

[38]  B. Pogue,et al.  Nine-Wavelength Spectroscopy Guided by Magnetic Resonance Imaging Improves Breast Cancer Characterization , 2012 .

[39]  B. Geller,et al.  The association of increased weight, body mass index, and tissue density with the risk of breast carcinoma in Vermont , 2000, Cancer.

[40]  Elkan F Halpern,et al.  Evaluating the correlation between film mammography and MRI for screening women with increased breast cancer risk. , 2009, Academic radiology.

[41]  J. Hurren,et al.  Modification of the Wise pattern breast reduction for oncological mammaplasty of upper outer and upper inner quadrant breast tumours: a technical note and case series. , 2013, Journal of plastic, reconstructive & aesthetic surgery : JPRAS.

[42]  B. Pogue,et al.  Combining near-infrared tomography and magnetic resonance imaging to study in vivo breast tissue: implementation of a Laplacian-type regularization to incorporate magnetic resonance structure. , 2005, Journal of biomedical optics.

[43]  X. Intes Time-Domain Optical Mammography SoftScan , 2005 .

[44]  Jennifer J. Gibson,et al.  Electromagnetic breast imaging: results of a pilot study in women with abnormal mammograms. , 2007, Radiology.

[45]  D. Plewes,et al.  Systematic Review: Using Magnetic Resonance Imaging to Screen Women at High Risk for Breast Cancer , 2008, Annals of Internal Medicine.

[46]  N. Boyd,et al.  Mammographic densities and breast cancer risk. , 1998, Cancer epidemiology, biomarkers & prevention : a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology.

[47]  B. Pogue,et al.  Evaluation of breast tumor response to neoadjuvant chemotherapy with tomographic diffuse optical spectroscopy: case studies of tumor region-of-interest changes. , 2009, Radiology.