Energy efficiency for cooling buildings in hot and dry regions using sol-air temperature and ground temperature effects

In hot and dry climates, air conditioning accounts for a large portion of total energy consumption; therefore, this paper aims to investigate the impact of sol-air temperature and ground temperature on the loss of cooling energy in hot and dry regions of Iran.,In line with this objective, the values of sol-air temperature along different directions and ground temperature at different depths were assessed with respect to climatic data of Yazd City. The impact of sol-air temperature and ground temperature on the rate of heat loss was investigated. So, energy loss of the walls aligned to four primary directions was calculated. This process was repeated for a 36 m2 building with three different shape factors. All analyses were conducted for the period from May to September, during which buildings need to be cooled by air conditioners.,Numerical analyses conducted for hot and dry climate show that sol-air temperature leads to a 41-17 per cent increase in the wall’s energy loss compared with ambient temperature. Meanwhile, building the wall below the surface leads to a significant reduction in energy loss. For example, building the wall 400 cm below the surface leads to about 74.8-79.2 per cent energy saving compared with above ground design. The results also show that increasing the direct contact between soil and building envelope decreases the energy loss, so energy loss of a building that is built 400 cm below the surface is 53.7-55.3 per cent lower than that of a building built above the surface.,The impact of sol-air temperature and ground temperature on the cooling energy loss of a building in hot and dry climate was investigated. Numerical analysis shows that solar radiation increases heat loss from building envelope. Soil temperature fluctuations decrease with depth. Heat loss from building envelope in an underground building is lower than that from building envelope in a building built above the ground. Three different shape factors showed that sol-air temperature has the maximum impact on square-shaped plan and minimal impact on buildings with east-west orientation.

[1]  Osama A.B. Hassan,et al.  An integrated approach to assessing the sustainability of buildings , 2016 .

[2]  Konstantinos Papakostas,et al.  Occupational and energy behaviour patterns in Greek residences , 1997 .

[3]  Behrouz Mohammad Kari,et al.  Cooling load reduction in office buildings of hot-arid climate, combining phase change materials and night purge ventilation , 2016 .

[4]  Alexandra R. Rempel,et al.  Climate-responsive thermal mass design for Pacific Northwest sunspaces , 2016 .

[5]  A.K.S. Thakur,et al.  Temperature variation in upper earth crust due to periodic nature of solar insolation , 1983 .

[6]  John Kaiser Calautit,et al.  A passive cooling wind catcher with heat pipe technology: CFD, wind tunnel and field-test analysis , 2016 .

[7]  G. Mihalakakou,et al.  Use of the ground for heat dissipation , 1994 .

[8]  Clinton Aigbavboa,et al.  Evaluation of vehicle lightweighting to reduce greenhouse gas emissions with focus on magnesium substitution , 2018, Journal of Engineering, Design and Technology.

[9]  Ra Rizki Mangkuto,et al.  Heating and cooling energy demand in underground buildings: potential for saving in various climates and functions , 2014 .

[10]  C. Giannakopoulos,et al.  Modelling the energy demand projection of the building sector in Greece in the 21st century , 2012 .

[11]  D. N. Asimakopoulos,et al.  Modelling the earth temperature using multiyear measurements , 1992 .

[12]  W. Marion,et al.  Solar radiation data manual for buildings , 1995 .

[13]  Omid Nematollahi,et al.  Solar energy potentials in Iran: A review , 2013 .

[14]  G. N. Tiwari,et al.  Performance evaluation and life cycle cost analysis of earth to air heat exchanger integrated with adobe building for New Delhi composite climate , 2009 .

[15]  Lorentz Jäntschi,et al.  Assessments about soil temperature variation under censored data and importance for geothermal energy applications. Illustration with Romanian data , 2013 .

[16]  Ali Mostafaeipour,et al.  Energy saving evaluation of passive systems for residential buildings in hot and dry regions , 2017 .

[17]  S. D. Probert,et al.  Sol-air temperature , 1977 .

[18]  S. C. Kaushik,et al.  Dynamic earth-contact building: A sustainable low-energy technology , 2007 .

[19]  Chadi Maalouf,et al.  Study of the energy performance of an earth—Air heat exchanger for refreshing buildings in Algeria , 2018 .

[20]  Maryam Banaei,et al.  Climate Comfort Comparison of Vernacular and Contemporary Houses of Iran , 2015 .

[21]  Sanaz Saljoughinejad,et al.  Classification of climatic strategies, used in Iranian vernacular residences based on spatial constituent elements , 2015 .

[22]  Viorel Badescu,et al.  Pneumatic and thermal design procedure and analysis of earth-to-air heat exchangers of registry type , 2011 .

[23]  G. Mihalakakou,et al.  On the application of the energy balance equation to predict ground temperature profiles , 1997 .

[24]  A. Sabziparvar,et al.  Estimation of global solar radiation in arid and semi-arid climates of East and West Iran , 2007 .

[25]  Sydney A. Baggs,et al.  Remote prediction of ground temperature in Australian soils and mapping its distribution , 1983 .

[26]  Adil Al-Mumin,et al.  Suitability of sunken courtyards in the desert climate of Kuwait , 2001 .

[27]  Baruch Givoni,et al.  Earth temperatures and underground buildings , 1985 .

[28]  Dennis L. Loveday,et al.  The cooling potential of earth-air heat exchangers for domestic buildings in a desert climate , 2006 .

[29]  Mattheos Santamouris,et al.  Passive cooling dissipation techniques for buildings and other structures: The state of the art , 2013 .

[30]  Akbar Alidadi Shamsabadi,et al.  Design and optimization of heating, cooling and lightening systems for a residential villa at Saman city, Iran , 2019, Journal of Engineering, Design and Technology.

[31]  Amos Madhlopa,et al.  Effect of controlling airflow in a solar chimney on thermal load in a built environment , 2016 .

[32]  Keith L. Bristow,et al.  Measurement of thermal properties and water content of unsaturated sandy soil using dual-probe heat-pulse probes , 1998 .

[33]  Ali Mostafaeipour,et al.  Economic evaluation for cooling and ventilation of medicine storage warehouses utilizing wind catchers , 2014 .

[34]  Jens Pfafferott,et al.  Evaluation of earth-to-air heat exchangers with a standardised method to calculate energy efficiency , 2003 .

[35]  Javier Ordóñez,et al.  Energy efficient design of building: A review , 2012 .

[36]  B. Rudolf,et al.  World Map of the Köppen-Geiger climate classification updated , 2006 .

[37]  Moncef Krarti,et al.  ANALYTICAL MODEL FOR HEAT TRANSFER IN AN UNDERGROUND AIR TUNNEL , 1996 .

[38]  Diane Bastien,et al.  Passive thermal energy storage, part 1: Design concepts and metrics , 2018 .

[39]  Ebrahim Solgi,et al.  Numerical analysis of the efficiency of earth to air heat exchange systems in cold and hot-arid climates , 2017 .