Application of EEG source localization algorithms to the monitoring of active pathways in peripheral nerves

Improved techniques for identifying active pathways in peripheral nerves using extraneural measurements would have numerous applications in the fields of neuroprostheses, neural system engineering, and diagnostics. In this study, we propose to approach this issue as an inverse problem of bioelectric source localization, using measurements from a multi-contact nerve cuff electrode. This problem is a modified version of the electroencephalogram / magneto-encephalogram (EEG/MEG) source localization problem. We therefore evaluate the performance of two well-known EEG/MEG source localization algorithms, namely sLORETA and sFOCUSS, when they are applied to the peripheral nerve problem. sLORETA is found to be a potentially viable approach, albeit with limited resolution, while sFOCUSS is found to produce too many spurious pathways in the presence of noise.

[1]  Karl J. Friston,et al.  An empirical Bayesian solution to the source reconstruction problem in EEG , 2005, NeuroImage.

[2]  I F Gorodnitsky,et al.  Neuromagnetic source imaging with FOCUSS: a recursive weighted minimum norm algorithm. , 1995, Electroencephalography and clinical neurophysiology.

[3]  R D Pascual-Marqui,et al.  Standardized low-resolution brain electromagnetic tomography (sLORETA): technical details. , 2002, Methods and findings in experimental and clinical pharmacology.

[4]  Dominique M. Durand,et al.  MODELING OF MAMMALIAN MYELINATED NERVE FOR FUNCTIONAL NEUROMUSCULAR STIMULATION. , 1987 .

[5]  Leonid Zhukov,et al.  Lead-field Bases for Electroencephalography Source Imaging , 2000, Annals of Biomedical Engineering.

[6]  Richard M. Leahy,et al.  Electromagnetic brain mapping , 2001, IEEE Signal Process. Mag..

[7]  T Stieglitz Matrix Cuff Electrodes for Fibre and Fascicle Selective Peripheral Nerve Recording and Stimulation , 2007 .

[8]  Manfred Fuchs,et al.  Evaluation of sLORETA in the Presence of Noise and Multiple Sources , 2003, Brain Topography.

[9]  Silvestro Micera,et al.  A critical review of interfaces with the peripheral nervous system for the control of neuroprostheses and hybrid bionic systems , 2005, Journal of the peripheral nervous system : JPNS.

[10]  M. Murray,et al.  EEG source imaging , 2004, Clinical Neurophysiology.

[11]  R. Plonsey Action potential sources and their volume conductor fields , 1977, Proceedings of the IEEE.

[12]  Roberto Domingo Pascual-Marqui REPLY TO COMMENTS MADE BY R . GRAVE DE PERALTA MENENDEZ AND , 2005 .

[13]  Fusheng Yang,et al.  Standardized shrinking LORETA-FOCUSS (SSLOFO): a new algorithm for spatio-temporal EEG source reconstruction , 2005, IEEE Transactions on Biomedical Engineering.