Electromagnetic Force and Vibration Study on Axial Flux Permanent Magnet Synchronous Machines With Dual Three-Phase Windings

This paper presents a detailed analysis of the electromagnetic force and vibration behavior of an axial flux permanent magnet synchronous machine (AFPMSM). First, the AFPMSM configuration and two types of dual three-phase winding are introduced. Subsequently, the electromagnetic force of the double-stator inner-rotor AFPMSM is investigated. Its spatial and temporal characteristics are derived analytically and validated through two-dimensional Fourier decomposition. A multiphysics model is established to calculate the vibration of the AFPMSM, which includes control, electromagnetic, structural, and vibration model. The accuracy of this multiphysics model is verified by the modal and vibration test. Furthermore, the vibration of the AFPMSM with three winding types considering current harmonics are calculated based on the multiphysics model. The vibration performance of the AFPMSM with three different winding types are compared and the mechanism of vibration is discussed. It was concluded that the novel detached winding could mitigate the vibration of dual three-phase AFPMSMs. Finally, the vibration test is carried out to validate the theoretical analysis and the experimental results agree well-with the simulation results. This paper provides an effective method for double-stator permanent magnet synchronous machine (PMSMs) to reduce vibration.

[1]  Thomas A. Lipo,et al.  Analysis of a concentrated winding induction machine for adjustable speed drive applications. II. Motor design and performance , 1991 .

[2]  Franck Scuiller,et al.  Multi-criteria-based design approach of multi-phase permanent magnet low-speed synchronous machines , 2009 .

[3]  Jussi Karttunen,et al.  Decoupled d-q Model of Double-Star Interior-Permanent-Magnet Synchronous Machines , 2013, IEEE Transactions on Industrial Electronics.

[4]  Xudong Wu,et al.  Vibroacoustic Prediction and Mechanism Analysis of Claw Pole Alternators , 2017, IEEE Transactions on Industrial Electronics.

[5]  J. L. Besnerais Vibroacoustic Analysis of Radial and Tangential Air-Gap Magnetic Forces in Permanent Magnet Synchronous Machines , 2015 .

[6]  Hew Wooi Ping,et al.  A Comprehensive Review of Axial-Flux Permanent-Magnet Machines , 2014, Canadian Journal of Electrical and Computer Engineering.

[7]  Ronghai Qu,et al.  Reduction of Unbalanced Axial Magnetic Force in Postfault Operation of a Novel Six-Phase Double-Stator Axial-Flux PM Machine Using Model Predictive Control , 2017, IEEE Transactions on Industry Applications.

[8]  Z Q Zhu,et al.  Analytical Modeling and Finite-Element Computation of Radial Vibration Force in Fractional-Slot Permanent-Magnet Brushless Machines , 2010, IEEE Transactions on Industry Applications.

[9]  Z. Q. Zhu,et al.  Torque Improvement of Dual Three-Phase Permanent-Magnet Machine With Third-Harmonic Current Injection , 2015, IEEE Transactions on Industrial Electronics.

[10]  Matteo Felice Iacchetti,et al.  Axial Flux PM Machines With Concentrated Armature Windings: Design Analysis and Test Validation of Wind Energy Generators , 2011, IEEE Transactions on Industrial Electronics.

[11]  Thomas A. Lipo,et al.  Pulse Width Modulation for Power Converters: Principles and Practice , 2003 .

[12]  Rik W. De Doncker,et al.  Exploring a vibration synthesis process for the acoustic characterization of electric drives , 2010, The XIX International Conference on Electrical Machines - ICEM 2010.

[13]  H. Razik,et al.  On the modeling and design of dual-stator windings to minimize circulating harmonic currents for VSI fed AC machines , 2004, IEEE Transactions on Industry Applications.

[14]  Peter Sergeant,et al.  An Inverse Thermal Modeling Approach for Thermal Parameter and Loss Identification in an Axial Flux Permanent Magnet Machine , 2019, IEEE Transactions on Industrial Electronics.

[15]  S. J. Yang,et al.  Low-Noise Electrical Motors , 1981 .

[16]  Massimo Barcaro,et al.  Faulty Operations of a PM Fractional-Slot Machine With a Dual Three-Phase Winding , 2011, IEEE Transactions on Industrial Electronics.

[17]  Shanming Wang,et al.  A PM Pole With Axial Varied Width for Vibration Mitigation in PM Brush DC Motors , 2019, IEEE Transactions on Industrial Electronics.

[18]  Shuguang Zuo,et al.  Optimization for Electromagnetic Noise Reduction in Claw Pole Alternator by Rotor Claw Chamfering , 2018, IEEE Transactions on Industrial Electronics.

[19]  K. Hameyer,et al.  Hybrid acoustic model of electric vehicles: Force excitation in permanent magnet synchronous machines , 2015, 2015 IEEE International Electric Machines & Drives Conference (IEMDC).

[20]  Shuguang Zuo,et al.  Axial Force and Vibroacoustic Analysis of External-Rotor Axial-Flux Motors , 2018, IEEE Transactions on Industrial Electronics.

[21]  F. Caricchi,et al.  Recent Advances in Axial-Flux Permanent-Magnet Machine Technology , 2012, IEEE Transactions on Industry Applications.

[22]  Fu Lin,et al.  Modeling and Analysis of Electromagnetic Force, Vibration, and Noise in Permanent-Magnet Synchronous Motor Considering Current Harmonics , 2016, IEEE Transactions on Industrial Electronics.

[23]  K. Atallah,et al.  Torque-ripple minimization in modular permanent-magnet brushless machines , 2003 .

[24]  Jiabin Wang,et al.  Six-Phase Fractional-Slot-per-Pole-per-Phase Permanent-Magnet Machines With Low Space Harmonics for Electric Vehicle Application , 2014, IEEE Transactions on Industry Applications.

[25]  Ronghai Qu,et al.  Six-phase double-stator inner-rotor axial flux PM machines with novel detached winding , 2017, 2015 IEEE Energy Conversion Congress and Exposition (ECCE).

[26]  Wonho Kim,et al.  A Numerical Prediction Model for Vibration and Noise of Axial Flux Motors , 2014, IEEE Transactions on Industrial Electronics.

[27]  Ahmed M. Massoud,et al.  Low Space Harmonics Cancelation in Double-Layer Fractional Slot Winding Using Dual Multiphase Winding , 2015, IEEE Transactions on Magnetics.

[28]  P. Pillay,et al.  Young's modulus for laminated machine structures with particular reference to switched reluctance motor vibrations , 2004, IEEE Transactions on Industry Applications.

[29]  Juha J. Pyrhönen,et al.  Direct Liquid Cooling Method Verified With an Axial-Flux Permanent-Magnet Traction Machine Prototype , 2017, IEEE Transactions on Industrial Electronics.