Feedback control of foot eversion in the adaptive peroneal stimulator

The limited ability to dorsiflex the foot, known as drop foot, can be treated by functional electrical stimulation. Therein, undesired foot eversion/inversion is a common problem which is usually corrected by tedious manual repositioning of the electrodes. We address this issue by presenting a feedback-control solution featuring three major contributions: (1) an algorithm for inertial sensor-based foot-to-ground angle measurement with periodic drift correction; (2) a three-electrode setup that allows distribution of an overall stimulation intensity to the tibialis anterior muscle and to the superficial peroneal nerve that innervates the fibularis longus muscle, thus decoupling dorsiflexion and eversion control; (3) a run-to-run controller and an iterative learning controller, both of which use step-by-step learning to achieve desired eversion foot-to-ground angles. Experiments with a chronic drop foot patient demonstrate compensation of undesired eversion/inversion within at most two steps, while dorsiflexion angle trajectories are not affected.

[1]  J. Perry,et al.  Comprar Gait analysis. Normal and pathological function | Burnfield, J. | 9781556427664 | Slack Incorporated , 2010 .

[2]  A.G. Alleyne,et al.  A survey of iterative learning control , 2006, IEEE Control Systems.

[3]  Thomas Seel,et al.  Online Gait Phase Detection with Automatic Adaption to Gait Velocity Changes Using Accelerometers and Gyroscopes , 2014 .

[4]  Qin Zhang,et al.  Dual predictive control of electrically stimulated muscle using biofeedback for drop foot correction , 2011, 2011 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[5]  Fredrik Gustafsson,et al.  Determining the initial states in forward-backward filtering , 1996, IEEE Trans. Signal Process..

[6]  P. Savage Strapdown Inertial Navigation Integration Algorithm Design Part 1: Attitude Algorithms , 1998 .

[7]  Alfred D. Grant Gait Analysis: Normal and Pathological Function , 2010 .

[8]  Thomas Seel,et al.  Iterative Learning Control for Variable Pass Length Systems , 2011 .

[9]  P H Veltink,et al.  Three dimensional inertial sensing of foot movements for automatic tuning of a two-channel implantable drop-foot stimulator. , 2003, Medical engineering & physics.

[10]  Jörg Raisch,et al.  Automatic control of a drop-foot stimulator based on angle measurement using bioimpedance. , 2008, Artificial organs.

[11]  P. Peckham,et al.  Functional electrical stimulation for neuromuscular applications. , 2005, Annual review of biomedical engineering.

[12]  Jeffrey M. Hausdorff,et al.  Neuroprosthesis for footdrop compared with an ankle-foot orthosis: effects on postural control during walking. , 2009, Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association.

[13]  T. Sinkjaer,et al.  A review of portable FES-based neural orthoses for the correction of drop foot , 2002, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[14]  Thomas Seel,et al.  IMU-Based Joint Angle Measurement for Gait Analysis , 2014, Sensors.

[15]  Joerg Raisch,et al.  Iterative Learning Control of Drop Foot Stimulation with Array Electrodes for Selective Muscle Activation , 2014 .

[16]  G. Johnson Control of Movement for the Physically Disabled , 2001 .

[17]  N.-O. Negard,et al.  Controlled FES-assisted gait training for hemiplegic stroke patients based on inertial sensors , 2009 .

[18]  Thomas Seel,et al.  Iterativ Lernende Regelung mit variabler Zykluslänge für FES-basierte Kompensation einer Fußheberschwäche / Iterative Learning Control with Variable Pass Length applied to FES-based Drop Foot Treatment , 2013, Autom..

[19]  T. Sinkjær,et al.  Control of Movement for the Physically Disabled , 2000 .