Leaflet Stresses During Full Device Simulation of Crimping to 6 mm in Transcatheter Aortic Valve Implantation, TAVI

[1]  E. Edelman,et al.  Understanding TAVR device expansion as it relates to morphology of the bicuspid aortic valve: A simulation study , 2021, PloS one.

[2]  F. Auricchio,et al.  CoreValve vs. Sapien 3 Transcatheter Aortic Valve Replacement: A Finite Element Analysis Study , 2021, Bioengineering.

[3]  S. Pasta,et al.  Computational Analysis of Self-Expanding and Balloon-Expandable Transcatheter Heart Valves , 2021, Biomechanics.

[4]  J. Carroll,et al.  STS-ACC TVT Registry of Transcatheter Aortic Valve Replacement. , 2020, Journal of the American College of Cardiology.

[5]  Austin J. Herrema,et al.  Thinner biological tissues induce leaflet flutter in aortic heart valve replacements , 2020, Proceedings of the National Academy of Sciences.

[6]  S. Siewert,et al.  Development of a constitutive law for numerical simulation of artificial leaflet-structures for transcatheter heart valve prostheses , 2019, Current Directions in Biomedical Engineering.

[7]  Patrick Segers,et al.  The Impact of Size and Position of a Mechanical Expandable Transcatheter Aortic Valve: Novel Insights Through Computational Modelling and Simulation , 2019, Journal of Cardiovascular Translational Research.

[8]  F. Migliavacca,et al.  On the Modeling of Patient-Specific Transcatheter Aortic Valve Replacement: A Fluid–Structure Interaction Approach , 2019, Cardiovascular Engineering and Technology.

[9]  Patrick Segers,et al.  Optimization of a Transcatheter Heart Valve Frame Using Patient-Specific Computer Simulation , 2019, Cardiovascular engineering and technology.

[10]  Ram P. Ghosh,et al.  Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage , 2018, Biomechanics and Modeling in Mechanobiology.

[11]  L. Ge,et al.  Stent and leaflet stresses in 26‐mm, third‐generation, balloon‐expandable transcatheter aortic valve , 2019, The Journal of thoracic and cardiovascular surgery.

[12]  Ram P. Ghosh,et al.  Principles of TAVR valve design, modelling, and testing , 2018, Expert review of medical devices.

[13]  John F LaDisa,et al.  Impact of annular and supra-annular CoreValve deployment locations on aortic and coronary artery hemodynamics. , 2018, Journal of the mechanical behavior of biomedical materials.

[14]  Q. Wang,et al.  Numerical Parametric Study of Paravalvular Leak Following a Transcatheter Aortic Valve Deployment Into a Patient-Specific Aortic Root. , 2018, Journal of biomechanical engineering.

[15]  N. Curzen,et al.  Transcatheter aortic valve implantation: where are we now? , 2017, Future cardiology.

[16]  Ferdinando Auricchio,et al.  Finite element analysis of TAVI: Impact of native aortic root computational modeling strategies on simulation outcomes. , 2017, Medical engineering & physics.

[17]  L. Ge,et al.  Stent and Leaflet Stresses in 29-mm Second-Generation Balloon-Expandable Transcatheter Aortic Valve. , 2017, The Annals of thoracic surgery.

[18]  N. Bressloff,et al.  The impact of imperfect frame deployment and rotational orientation on stress within the prosthetic leaflets during transcatheter aortic valve implantation. , 2017, Journal of biomechanics.

[19]  Wei Sun,et al.  Transcatheter Valve Underexpansion Limits Leaflet Durability: Implications for Valve-in-Valve Procedures , 2016, Annals of Biomedical Engineering.

[20]  Jos Vander Sloten,et al.  A validated methodology for patient specific computational modeling of self-expandable transcatheter aortic valve implantation. , 2016, Journal of biomechanics.

[21]  Alberto Redaelli,et al.  Impact of different aortic valve calcification patterns on the outcome of transcatheter aortic valve implantation: A finite element study , 2016, Journal of biomechanics.

[22]  N. Bressloff,et al.  Assessing the impact of including leaflets in the simulation of TAVI deployment into a patient-specific aortic root , 2016, Computer methods in biomechanics and biomedical engineering.

[23]  Claudio Chiastra,et al.  Fluid–Structure Interaction Model of a Percutaneous Aortic Valve: Comparison with an In Vitro Test and Feasibility Study in a Patient-Specific Case , 2016, Annals of Biomedical Engineering.

[24]  A. Azadani,et al.  Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion. , 2015, Journal of biomechanics.

[25]  Jonathon Bailey,et al.  Implications for leaflet behaviour in heavily calcified patient-specific aortic roots : simulation of transcatheter aortic valve implantation , 2015 .

[26]  Ted J. Vaughan,et al.  Simulation of Self Expanding Transcatheter Aortic Valve in a Realistic Aortic Root: Implications of Deployment Geometry on Leaflet Deformation , 2014, Annals of Biomedical Engineering.

[27]  F Auricchio,et al.  Simulation of transcatheter aortic valve implantation: a patient-specific finite element approach , 2014, Computer methods in biomechanics and biomedical engineering.

[28]  Arash Kheradvar,et al.  The effects of transcatheter valve crimping on pericardial leaflets. , 2014, The Annals of thoracic surgery.

[29]  Silvia Schievano,et al.  Patient-specific simulations of transcatheter aortic valve stent implantation , 2012, Medical & Biological Engineering & Computing.

[30]  Thomas Walther,et al.  Crimping may affect the durability of transcatheter valves: an experimental analysis. , 2011, The Annals of thoracic surgery.

[31]  Kewei Li,et al.  Simulated Thin Pericardial Bioprosthetic Valve Leaflet Deformation Under Static Pressure-Only Loading Conditions: Implications for Percutaneous Valves , 2010, Annals of Biomedical Engineering.

[32]  C. Otto,et al.  Timing of aortic valve surgery , 2000, Heart.

[33]  Ferdinando Auricchio,et al.  Shape-memory alloys: modelling and numerical simulations of the finite-strain superelastic behavior , 1997 .