Regional myocardial oxygen consumption determined noninvasively in humans with [1-11C]acetate and dynamic positron tomography.

Experimental studies of animals have previously demonstrated the validity of [1-11C]acetate as a tracer of oxidative metabolism for use with positron emission tomography. The present study was undertaken to define in normal human volunteers the relation between myocardial clearance kinetics of [1-11C]acetate, and the rate-pressure product as an index of myocardial oxygen consumption. Twenty-two studies were performed of 12 volunteers. The rate-pressure product was increased with continuous supine bicycle exercise in six studies. Of the 16 resting studies, seven were performed in the fasted state and nine following an oral glucose load, to define possible effects of substrate availability on the tracer-tissue kinetics. Myocardial tissue time-activity curves were biexponential. Clearance of activity was homogeneous throughout the myocardium. The rate constants k1, obtained from biexponential fitting, and kmono, obtained by monoexponential fitting of the initial linear portion of the time-activity curves, correlated well with the rate-pressure product. Although the correlation coefficient was higher for k1 than for kmono (0.95 vs. 0.91), analysis on a sectorial basis showed less regional variability in kmono. This suggests that kmono, which is more practical than k1 because it requires shorter acquisition times, may be more clinically and experimentally useful for detection of myocardial segments with abnormal oxygen consumption. Overall, changes in myocardial substrate supply were without significant effect on the relation between the rate constants (k1 and kmono) and the rate-pressure product, although a small decrease in kmono/rate-pressure product was observed following oral glucose by paired analysis in four subjects. It is concluded that [1-11C]acetate can be used for the noninvasive measurement of myocardial oxygen consumption in humans with positron emission tomography, and, thus, has clinical and experimental potential as a tool for the understanding and diagnosis of myocardial disease.

[1]  R. Grossman,et al.  Effects of substrate availability on myocardial C-11 palmitate kinetics by positron emission tomography in normal subjects and patients with ventricular dysfunction. , 1986, American heart journal.

[2]  V. Pike,et al.  Preparation of [1-11C]acetate--an agent for the study of myocardial metabolism by positron emission tomography. , 1982, The International journal of applied radiation and isotopes.

[3]  M. Ter-pogossian,et al.  Effect of Flow‐Independent Reduction of Metabolism on Regional Myocardial Clearance of 11C‐Palmitate , 1982, Circulation.

[4]  L. Katz,et al.  Determinants of coronary flow and myocardial oxygen consumption. , 1962, The American journal of physiology.

[5]  J. Barrio,et al.  C- 11 labeled palmitic acid for the noninvasive evaluation of regional myocardial fatty acid metabolism with positron-computed tomography. I. Kinetics of C- 11 palmitic acid in normal myocardium. , 1982, American heart journal.

[6]  A. DeMaria,et al.  Indirect assessment of myocardial oxygen consumption in the evaluation of mechanisms and therapy of angina pectoris. , 1974, The American journal of cardiology.

[7]  M. S. Klein,et al.  External assessment of myocardial metabolism with C-11 palmitate in vivo. , 1980, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  S. Epstein,et al.  The use of indirect indices of myocardial oxygen consumption in evaluating angina pectoris. , 1973, Chest.

[9]  H. Schelbert,et al.  Radiolabeled Acetate as a Tracer of Myocardial Tricarboxylic Acid Cycle Flux , 1988, Circulation research.

[10]  E. Varnauskas,et al.  Coronary circulation during heavy exercise in control subjects and patients with coronary heart disease. , 2009, Acta medica Scandinavica.

[11]  G. Hellige,et al.  Validity of myocardial oxygen consumption parameters , 1979, Clinical cardiology.

[12]  E. Hoffman,et al.  Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size , 1979, Journal of computer assisted tomography.

[13]  J. Barrio,et al.  C- 11 labeled palmitic acid for the noninvasive evaluation of regional myocardial fatty acid metabolism with positron-computed tomography. II. Kinetics of C- 11 palmitic acid in acutely ischemic myocardium. , 1982, American heart journal.

[14]  J. Barrio,et al.  C-11 palmitate for the noninvasive evaluation of regional myocardial fatty acid metabolism with positron computed tomography. III. In vivo demonstration of the effects of substrate availability on myocardial metabolism. , 1983, American heart journal.

[15]  J. Williamson Effects of insulin and starvation on the metabolism of acetate and pyruvate by the perfused rat heart. , 1964, The Biochemical journal.

[16]  E. D. Jacobson,et al.  Blood flow and gastrointestinal function. , 1971, Gastroenterology.

[17]  A. Liedtke Alterations of carbohydrate and lipid metabolism in the acutely ischemic heart. , 1981, Progress in cardiovascular diseases.

[18]  J. Barrio,et al.  C-11 palmitate for the noninvasive evaluation of regional myocardial fatty acid metabolism with positron-computed tomography. IV. In vivo evaluation of acute demand-induced ischemia in dogs. , 1983, American heart journal.

[19]  G. Hellige,et al.  Comparison of Myocardial Oxygen Consumption Indices in Man , 1980, Clinical cardiology.

[20]  E. Hoffman,et al.  Validation of PET-acquired input functions for cardiac studies. , 1988, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[21]  A. Luxen,et al.  Noninvasive quantitation of regional myocardial oxygen consumption in vivo with [1-11C]acetate and dynamic positron emission tomography. , 1989, Circulation.

[22]  J. Barrio,et al.  Retention and clearance of C-11 palmitic acid in ischemic and reperfused canine myocardium. , 1985, Journal of the American College of Cardiology.

[23]  G. Hellige,et al.  Usefulness and limitations of myocardial oxygen consumption indices , 1980, Clinical Cardiology.

[24]  Michael E. Phelps,et al.  Semiautomatic Software For Quantitative Analysis Of Cardiac Positron Tomography Studies , 1988, Medical Imaging.

[25]  R. Denton,et al.  Control of the tricarboxylate cycle and its interactions with glycolysis during acetate utilization in rat heart. , 1970, The Biochemical journal.

[26]  G. A. Rooke,et al.  Work as a Correlate of Canine Left Ventricular Oxygen Consumption, and the Problem of Catecholamine Oxygen Wasting , 1982, Circulation research.

[27]  M. Phelps,et al.  Identification of impaired metabolic reserve by atrial pacing in patients with significant coronary artery stenosis. , 1986, Circulation.

[28]  J. Fleiss,et al.  Some Statistical Methods Useful in Circulation Research , 1980, Circulation research.

[29]  Y. Wang,et al.  Hemodynamic correlates of myocardial oxygen consumption during upright exercise. , 1972, Journal of applied physiology.

[30]  M. Ter-pogossian,et al.  Localization of viable, ischemic myocardium by positron-emission tomography with 11C-palmitate. , 1981, Circulation.

[31]  Michael E. Phelps,et al.  Dynamic, Gated and High Resolution Imaging with the ECAT III , 1986, IEEE Transactions on Nuclear Science.

[32]  Kyuhyun Wang,et al.  Hemodynamic Predictors of Myocardial Oxygen Consumption During Static and Dynamic Exercise , 1974, Circulation.

[33]  S. Bergmann,et al.  Noninvasive assessment of canine myocardial oxidative metabolism with carbon-11 acetate and positron emission tomography. , 1988, Journal of the American College of Cardiology.

[34]  B. Sobel,et al.  Efflux of metabolized and nonmetabolized fatty acid from canine myocardium. Implications for quantifying myocardial metabolism tomographically. , 1985, Circulation research.

[35]  S. Bergmann,et al.  Validity of estimates of myocardial oxidative metabolism with carbon-11 acetate and positron emission tomography despite altered patterns of substrate utilization. , 1989, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[36]  B E Sobel,et al.  Delineation of myocardial oxygen utilization with carbon-11-labeled acetate. , 1987, Circulation.